<?xml version="1.0" encoding="UTF-8"?>
<itemContainer xmlns="http://omeka.org/schemas/omeka-xml/v5" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://omeka.org/schemas/omeka-xml/v5 http://omeka.org/schemas/omeka-xml/v5/omeka-xml-5-0.xsd" uri="https://www.nal.usda.gov/exhibits/speccoll/items/browse?advanced%5B0%5D%5Belement_id%5D=39&amp;advanced%5B0%5D%5Btype%5D=is+exactly&amp;advanced%5B0%5D%5Bterms%5D=et+al.&amp;output=omeka-xml" accessDate="2026-10-05T21:52:16+00:00">
  <miscellaneousContainer>
    <pagination>
      <pageNumber>1</pageNumber>
      <perPage>15</perPage>
      <totalResults>18</totalResults>
    </pagination>
  </miscellaneousContainer>
  <item itemId="6535" public="1" featured="0">
    <fileContainer>
      <file fileId="2337">
        <src>https://www.nal.usda.gov/exhibits/speccoll/files/original/3822038d9ceab5efc202dd6661e0ed1f.pdf</src>
        <authentication>9dbb381561ce5af93ecedcda02b02a03</authentication>
        <elementSetContainer>
          <elementSet elementSetId="4">
            <name>PDF Text</name>
            <description/>
            <elementContainer>
              <element elementId="60">
                <name>Text</name>
                <description/>
                <elementTextContainer>
                  <elementText elementTextId="64286">
                    <text>Item D Number

05557

D

Author

MacLeod, Colin M.

CorporatB Author

Panel on Herbicides, President's Science Advisory Com

Report/Article Title

Re

NotScannBfl

P°rt on 2,4,5-1

Journal/Book Title
Year

197

Month/Day

Ju|

Color

°

v

D

Number of Images

°

Desorlpton Notes

See item 882 for a later version

Tuesday, March 19, 2002

-

Page 5557 of 5611

�RA k
/I\A /,FT

R E P O R T ON 2, 4, 5-T

•

PANEL ON HERBICIDES
i*

PRESIDENT'S SCIENCE ADVISORY COMMITTEE

c
-

ll

�MEMBERS OF "THE PANEL

**•

Dr. Colin M. ^MacLeod, Chairman , New York University Medical
Ce-nter,-New Y o r k , New York
Dr. John D. Baldeschwieler, Stanford |University, Standford,
California
;i
'•
;

i
i

•

Dr. Nyle-C.' Brady, Cornell University, Ithaca, New York
" D r . Emmamfel Farber, University of [Pittsburgh, Pittsburgh,
"Pennsylvania|
Dr. 'Paul Kotin, National Institute of Environmental Health •
•• -~''~ Sciences, Durham, Nor£h;Carolina
Dr. Brian Ma.cMahoh, Harvard School of Public. Health, Boston,
~~ Massachusetts
Dr. Norton Nelson, New York University Medical Center,
' ' '
New York, New York
Dr. L. Dale Newsom, Louisiana State University, Baton Rouge, .
Louisiana
••
Dr. John W. Tukey, Princeton University, Princeton, New Jersey
G. Wilson, Children's Hospital Research Foundation,
• :"C_incinnati, Ohio

Dr. Edward J. Burger, Jr. , Staff,-' Technical Assistant, Office
of Science and Technology, Executive Office
• . '~ "of the President, Washington, D. C.

�REPORT ON 2,4, 5-T
Contents
I.

"~ Summary and Recommendations

II.

Introduction

III.

Chemistry

-. ..—

A.
B.
,C.
D.
E.

'-'"/ F.
IV. • .

V.

C.

D.
E.
F.
G.

-

Analytic Methods

Chemical Stability of 2,4, 5-T
' "

'

Production
..
;
' Uses
•
1. Domestic
2. Military
•• '
_
Cost Sharing Program
i

'

.

'
.

.

Acute Toxicological Investigations
" Occupational Experience
National Cancer Institute Screening
Study
'
"
Reports of Birth Defects
Toxicity of Dioxin
'
.
."
Teratogenesis Testing'
' Summary of Experiments

Residues of 2, 4, 5-T in the Environment
A.
B.

VII.

• Synthesis
'
.
.
.
Formulation
Solubilities
Purity of Technical Grade Material

Toxicology
A.
B.
C.

VI.

'

Uses and Significance
A._
3.'

•

.

Residues of 2, 4, 5-T resulting from.
recommended uses in the United States
Residues of 2, 4-D and 2, 4, 5-T resulting
from, recommended uses by the
military for defoliation.

Some Ecological Effects

�SECTION I
SUMMARY AND RECOMMENDATIONS
A. .

Summary

B.

Recommendations-

�I.

A.

SUMMARY AND RECOMMENDATIONS

Summary

This review of the herbicide, 2 , 4 , 5 - T , began with an examination of the r e s u l t s f r o m an experimental screening study which implicated
it as a potential teratogen. It quickly became evident that examination
f r o m such a r e s t r i c t e d basis was inadequate. T h e r e f o r e , the Panel'
decided to study m o r e broadly important aspects of 2 , 4 , 5 - T , including
details .of_its c h e m i s t r y and purity, its domestic uses and their relative
importance,' the military significance attached to 2 , 4 , 5 - T as a defoliant,
residue levels (in o r d e r to estimate probabilities of human e x p o s u r e ) ,
general e f f e c t s on the environment, as well as its toxicity. • In examining the toxicity of 2 , 4, 5-T, 'the Panel reviewed the information available
from the literature (as well as some unpublished documents) which had
been considered in the past in establishing policy decisions for the various
uses to which' this pesticide had been put. '
.

Selection of 2, 4, 5-T as an example for detailed examination
has had a.number of advantages. There has been an extensive history
of use and experience. 2, 4, 5_-Tjwas f i r s t r e g i s t e r e d on March 2, 1948,.
by the Amch.em Products Company^ Ambler, Pennsylvania. Since that •
time considerable information on its properties and uses has accumulated.
Furthermore, it has been the subject of reviews by others in the past.
Finally, the pr^pblem^which brought it to the Panel's attention, suspicion of
teratogenicity, appears to be a relatively manageable problem in contrast
to many other biological e f f e c t s , notably tumor production and genetic alter.
This is important since the r e c o m m e n d a t i o n s which follow can be" made
with a degree of confidence that cannot be applied to carcinogenic or
mutagenic effects. For example, the d o s e - r e s p o n s e characteristic of .
( teratogens is generally r e s t r i c t e d to a relatively small range of dosage.
Accordingly, a threshold below which no e f f e c t v/ould be expected can be. •
; assigned with more certainty. Experiments to determine this range of
( v a l u e s can be p e r f o r m e d in a relatively short time and do not require
very large numbers of animals.
i
The Panel is gratified that some of its recommendations are
already being carried out, expecially further experiments to confirm
and extend'the results of the original screening that indicated 2 , 4 , 5 - T
to be tera'togenie.
. -.

�In c o n s i d e r i n g the c h e m i s t r y of 2, 4, 5-T, our attention was d r a w n
to impurities which can result f r o m the manufacturing process. Particular attention was f o c u s e d on a single impurity, 2 , 3 , 7 , 8 tetrachlorodibcnzo-p-dioxin, which o c c u r s in commercial p r e p a r a t i o n s of the
. . . „ }J
herbicide in highly variable amounts unlcs.s particular care is taken
. . ..-. ...
to exclude it. This impurity is'extremely toxic. Its p r e s e n c e depends
upon variations in the reaction conditions. Other dioxins (some more
toxic than 2, 3, 7, 8-tctrachlorodibenzo-p~dioxin) can be 'formed f r o m .
various impurities in the starting materials. The dioxin impurity came .
to particular attention when the U.S. herbicide industry was asked to .
produce larger quantities of 2,4, 5-T during the middle 1960's. However, ^itsp r e s e n c e as an il'npurity and certain of its acute toxic e f f e c t s had been known
since 1957. Its concentration in commercial 2, 4, 5-T has been greatly •
.-reduced'"in the pa.st year or so.
* Analytic methods available for 2 , 4 , 5-T*are accurate and reliable., &gt; '••
With the possible exception of citrus f r u i t s , determination of residues
;.•
in-food has not presented a serious .analytic-problem.
. .'.,
.£..'-.

2, 4, 5-T is relatively labile in nature. Residues in soils and
water are not persistent except under unusual conditions. The herbicide.
• • is not stored in'plants or animals to a'significant extent.
Production of 2, 4, 5-T in the United States rose rapidly between
I960 and 1968, Civilian use, most of which is for clearing of range land
and rights-of-way and for treatment of p a s t u r e s , declined about 50%
' •:
between .1964 and 1966. Military use of 2, 4, 5-T as a defoliant, expressed
:,
as number of acres sprayed, rose sharply between 1964 and 1967 but has
declined since then. Although it accounts for only a small amount of the
,- ;1
total usage of 2, 4, 5-T, its place in control of aquatic weeds is significant..
There is a small but important list of agricultural uses where 2, 4, 5-T
is applied to food crops. Potential human exposure i's recognized in
• .-.
this direct application to food crops, in range and pasture lands grazed
by domestic meat and dairy animals, and possibly, in water supplies
derived f r o m treated waterways and streams. The economic importance
of the various uses is considerable, but is very much less than that of
2, 4-D. Substitution of 2, 4-D for 2, 4,.5-T can be made for certain uses.
Defoliation, using mixtures of 2, 4-D and 2, 4, 5-T, has been
"employed in Vietnam since 1962 , ' more intensively since 1967.
Although not rigorously demonstrated, its military usefulness
has been considered to be very high.

�- 3 -

•

The background of toxicological information on 2, 4, 5-T
is thin.
Most of the animal studies have been concerned with
acute toxicity (single doses or repeated doses for short periods of time).
Based on__tho s c cxpc rime n ts . the acute toxicity of 2, 4, 5-T was found to^
be low.
.
Little is. known 'of the details"of the metabolic handling
of the material although rapid excretion in the u r i n e seems to
be the rule.

/
I
I
7
A
/
/

The screening study supported by the I\T a t i onal^Cj-jTi eg r I nstitute on the toxicity of certain pesticides and other important industrial
chemicals m a r k s an important advance in toxicological testing in that
the tests w e r e d e s i g n e d to detect carcinogenic, teratogenic and mutagenic
potential. TJh^jprj^2g.^a/dojri_of_ 2 ,' 4 . 5-T us^_,in_thQse_te-s_ts_v.^as shown r to
be t e r a t o R c n i c in both j-n.t^ajifLnii.c e . There was no
carcinogeiiic. While this study had a number of limitations which qualifTellTts u s e f u l n e s s , the teratogenic results we're sufficiently convincing '• •
so that the Panel u r g e d , early in its discussions, that they be repeated
and extended using better characterized preparations of 2, 4, 5-T, Analysis
of a sample of the 2, 4, 5-T preparation u s e d in the original teratogenesis
study revealed a dioxin level of about 27 pprn. _Such a considerable con-_
tamination by this highly toxic material r a jjgjsj-jh e^ques. t ion_a_s to wh ether
^
2,_4_,_5^T itself, by the dioxin
___
impurity or by other imp_urities in. the commercial preparation testea.
The Pa-nel v/as aware of press reports of increased birth '
defects in Vietnam attributed to the use of defo_liants. The lack of
accurate epidemiological data on the incidence and kinds of birth
defects in the Vietnamese population b e f o r e or since the military use of .
defoliants precludes any estimate as to whether an increase in birth
defects has occurred. Calculations of potential human exposures f r o m
sources such as drinking water or direct fallout make this "appear unlikely
(though theoretically possible). •
"
A r ej/i_ejA^j:&gt;f_j^hj^^^
or p;anj. s ms_^jej/&lt;iaj^__£ejar_ h_ar^mf ul c QHs_eo^u£nc e s_jif its r e c^mrnenQe d
Indviced changes in vegetation are followed by alteration in
numbers of wild animals. Accelerated crosioai' of 'soil may follow the
killing of brush with herbicides but mechanical removal causes greater
erosion.
•
.
• .

�- 4 B.

Re c o m m on d a li o n s
' i'

*

*

1. Fxirthcr s t u d i e s .
a . The animal e x p e r i m e n t s which r a i s e d the qv.c-stion of the
te_ra_togcnic potential of 2,,4,5-T should be extended to include a. v.idgjr.
rajTg_e of d o s e s ad minis tor cd to non-i'nbred strains of animals and to
l a r g e r n u m b e r s 01 a n i m a l s . _
b . The i m p o r t a n c e of the impurities in 2 , 4 , 5 -T as potential health
h a z a r d s s h o u 1 d b e a s c e r tain e d . R e c e n t experiments d e s i g n e d to distinguish
between 2, 4, 5 - T and the dioxin impurity have s u g g e s t e d that both the
herbicide and we dioxin are potential t e r a t o g e n s in some experimental
animals. Hc&gt;\vej/£r_.__£2\perirnents n e c e s s a r y to e s tab li s hthi^ arts \v er
have Q i ^ X 3 » ~ - ' l c ^ as
In addition, there may be additional impurities in commercially p r e p a r e d phenoxy herbicides which may be biologically active.
c. The metabolism of Z, 4. 5-T in humans should be d e t e r m i n e d •
and conaparcd to that in e x p e r i m e n t a l animals.
'" " '
"
' I
i
*
d. The level of dioxin, a recognized impurity in 2,4, 5-T should
be rigorously controlled and -limited to not |more than 0. 5 ppm. A
t
reduction to not more than 0. 1 ppm should be urged. The family of '
compounds, known as polychlorinated dioxi'ns, have been found to be
highly toxic and capable of eliciting teratog'enic e f f e c t s . The several
dioxins vary widely in toxicity. F u r t h e r , it appears that they may
arise in the environment f r o m multiple sources. Therefore, control
over known sources should be exercised to the extent possible. •
2.

R e s t r i c t i o n on use of 2, 4, 5-T.

.

•

•

A decision to r e s t r i c t the use of 2 , 4 , 5-T should not be bas ed on
the isolated find ing of toxicity but on the expected e x p o s u r e follov.'ing
recomrnencled u s e _ m relation to dose r e s ponse e f f e c t s .
In general, the imposition of restrictions on the use of a pesticide
would appear to be a function of two f a c t o r s , the potential for human
exposure and the nature of the toxic e f f e c t s . For example, if c a r e f u l l y
documented r e s ^d^ejinf_or_maj:^^
osu r e ,
j^e^j^k of ^acrvej^se eff ecjs__wc^d_b^lcss9'i gnificant than if exposvire
were widespread.
•
~~~
"™
~~
~
'
tha t s i gni,f ic ant r e_sidue s
_
would result f r o m recommended u s e s of Z, 4, 5-T on food crops. It is

�possible for residues to occur in tissues of animals grazing on recently
treated pastures and range land. In fact, the only residues which have
been identified in the total diet studies have o c c u r r e d in meat and dairy
products. ' However, the few cases in which r e s i d u e s have been discovered
have all been at levels well below those which would result in significant _
toxicity f o r man.
.
' . - *
r'"'^!

'

The cxpg.rirnental finjding_of ter a to gene sis requires furthjvr
c lab o r &amp;ti o n 1 ve'f o &lt;T-o- i t c a n be i n t e r p r e t e d as a human health h a z a r d .

;
^_
'/
• '.
' •

.

\
i

The r i s k of t e r a t o g e n i c e f f e c t s should be placed in perspective.
' '
Teratogenesis i n d u c e d by chemicals is a f e t a l r e s p o n s e at a particularly
sensitive p e r i o d in embryonic development to lower d o s e s of the chemical
than .are acutely. to.xic_to the mother. Birth defects can be produced in
j
the embryo through many mechanisms of injury when the agents are ad' :
ministered during-critical periods of organogenesis. ' It is generally
• ' ••
held that by c a r e f u l choice of dosage, which may be close to the acutely
toxic dose for the mother, most chemicals might be 'shown to be
teratogenic in animals. For a variety of r e a s o n s , it is not possible to
. :
translate directly 'the results of experiments in animals to man. There •
are differences in sensitivity which arise f r o m differences in metabolism.
Comparative metabolic studies in man and animals, therefore, are
important in interpreting toxicity for 'man. .
•
The important consideration is not only the demonstration of
teratogenicity, which" may occur with many chemicals'at selected dosages,
but the estimation' of the likelihood of teratogenic effects with the
' amounts likely to be ingested incident to recommended use. To restrict
or ban usage of chemicals on the basis of demonstration °^ teratg_genicity
at do_se_Leyels which far ex_cjij(id_jui£lial_c1r__e^j:)ected exposures is u n ~
^rea^onab le_an d p nu 1 d_well d e n y u s a g e o f chemicals whose benefits far
outweigh risks.

�-63. R e g i s t r a t i o n s of 2 , 4 , 5-T for u s e s on p a s t u r e s and r a n g e l a n d s
should be t r e a t e d as r e g i s t r a t i o n s for food c r o p u s e s .
It is possible for r e s i d u e s of 2, 4, 5-T to occur in milk and tissues
. o f animals g r a z i n g 'on land recently t r e a t e d with 2, 4, 5-T. To date,
meat and dairy p r o d u c t s have been the only food products in'the total
diet studies that contained measurable amounts of 2, 4, 5-T. Use on
r a n g e and p a s t u r e land should be included in registration for use onfood crops.
- 4- M o n i t o r i n g of 2 , 4 , 5-T r e s i d u e s should be significantly expanded^
e s p e c i a l l y f o r meat and milk. In sampling meat and milk, special
attention should be given to geographic a r e a s where, treatment of
pastures and r a n g e lands with 2 , 4 , 5-T is most common. The 2, 4, 5-T
r e s i d u e s that may o c c u r in meat and milk of animals a.llpwed to graze
on p a s t u r e s and ra_nge lands t r e a t e d according to current recommenda- •
tions' should also be r e s t u d i e d .
' •
f
5.

Prompt and expeditious r e l e a s e of information.

As new information is developed on pesticides,• it should be
d i s s e m i n a t e d promptly to individuals and or sanitations that a r e
legitimately c o n c e r n e d as m a n u f a c t u r e r s , f o r m u l a t o r s u s e r s and
s c i e nti f i c i nv e s ti g a t o r s .
'
"
The case of 2, 4, 5-T is illustrative of inordinate delay.in makingavailable new r e s e a r c h i n f o r m a t i o n as it became known. The screening
study of pesticides which was c a r r i e d out by Bionetics Corporation
under contract wi-th the National Cancer Institute was completed about
August 1968. It was 14 months later when the Government announced
its coordinated actions on restricting the use'of 2,4, 5-T. It-was only
a f t e r an additional s e v e r a l months that the detailed data of the screening
study were made publicly available. A centralized.mechanism for handling
and disseminating-new information about'pesticides could help alleviate
this problem.
•
.
.
^• Interim imposition of r e s t r i c t i o n s on pesticide use while
additional i n f o r m a t i o n is being c o l l e c t e d .
A mechanism should be e s t a b l i s h e d for r e s t r i c t i n g the u s e _of_a_
r e g i s t e r e d pesticide ternporarily_p_n the basis of information which
implicates the c h e m i c a l as a_possibJ_e_JT£jij.t}i_ha.zard pending the collection
o f rn or e d c f i n i ti v e i n f o r _ma id o n.
If a p e s t i c i d e is a l r e a d y in established use, the decision is! p a r t i c u l a r l y
difficult. Long established use inevitably implies a d e p e n d e n c e upon it
by the consumer and a c o r r e s p o n d i n g reluctance by the m a n u f a c t u r e r
to withdraw it f r o m the market.
.
..

�At the present time, a registration may be held in abeyance
only by cancellation or suspension. .Because of the serious import
of these actions they are put into e f f e c t with considerable reluctance.
They \vere_not designed for situations such as the present with respect
to 2 4 5-T where te m PO
°"5e'
or s us pc n sion p f r o gist ra ti on_,rm_gh_t_ha 1 ve b c e n a^mo r e _ajjpj;o pr i a t e a c t i o n .
Such an alternative c o u r s e of action is not possible under p r e s e n t
regulations.
There is need for a mechanism w h e r e b y the use of a pesticide
or other chemical that may a f f e c t human health can be t e m p o r a r i l y
r e s t r i c t e d or held in abeyance. Such action would permit the gathering ' •
of m o r e . d e f i n i t i v e information in time for sufficient consultation to permit
a decision that would protect the public health and not impose an undue
economic burclenrcm the p r o d u c e r s , m a r k e t e r s , and u s e r s of a product.
Coincident with the imposition of r e s t r i c t i o n s on a pesticide, a mechanism
should be available for informing and educating pesticide u s e r s and
applicators so as to make them more r e s p o n s i b l e agents.
7. There is an xir.gent need for a_focus of responsibility in D / H E W '
to coordinate and monitor the toxicitv 'and health activities related to •
———•--—• -- ---effects of pesticides.

\
} i
.i

Information about the health effects of a pesticide derives from
a variety of sources including occupational exposures, residue monitoring, toxicological investigations, clinical experience and epidemiological
studies. In the past, there has' been no single focus within D / H E W which
has been c o n c e r n e d with all of these s o u r c e s of data and, more important,
which has had the authority and responsibility to coordinate new invest!\
gative initiatives. The new Advisory Committee on" Pesticides to the
\
Secretary of D / H E W can be expected to serve as a source of e x p e r t
advice but cannot fill the essential need for a focus of responsibility
and authority at the level of the Office of the Secretary. Consideration
of the functions to be fulfilled and the r e s o u r c e s available s u g g e s t s that
this responsibility should be assigned to the A s s i s t a n t S e c r e t a r y for
Health and Scientific A f f a i r s because the various components of D / H E W '
concerned most with aspects of the health e f f e c t s of pesticides r e p o r t
directly to him (National Institutes of Health, Food and D r u g Administration,
National Communicable D i s e a s e Center, Environmental Health Service).
8. • Information provided in applications for registrations of pesticides^
should take into account not only the PejUcidc for which registration is^
s ought but E; hould id cntify other substanc e s inc. luding vehicles used in
i o r m u 1 a ti o n s . V i . n e r t n i n g r p d i e n t s , a n d i m p u r i t i c_3 .

�o-

Investigation of the synthesis of 2, 4, 5-T and examination of the
m a n u f a c t u r i n g p r o c e s s r e v e a l e d that an e x t r e m e l y toxic impurity,
2, 3, 7, S - t e t r a c h l o r d d i b e n z o - p - d i o x i n , p r e s e n t in variable .amount in
commercial preparations of 2, 4, 5-T, may account for 'some of the
toxicological characteristics assigned to 2, 4, 5-T itself . The presence
of this impurity was r e c o g n i z e d as early as 1957. However, the
importance of this impurity was not generally r e c o g n i z e d in the United States
until after 1964. It a p p e a r s logical that g r e a t e r specificity in identifying
the components and properties of thej. mixture of materials which areregistered u n d e r - a single name would increase the probability of identification of potentially toxic substances.
•
p r o c e d u r e s should include toxicological studies
on r e l a t e d c o m p o u n d s where j u d g m e n t i n d i c a t e s this to be desirable.
•
"~~
\
« Toxicological studies provided as information in behalf of •
2, 4, 5-T registration were performed on a Variety of related compounds
(the f r e e acid, several types of e s t e r s and 3. variety of salts). Results
of these, tests w e r e r e g a r d e d as being interchangeable and applicable
to the related compounds. There is evidence to caution against this
concept; For example, the National Cancer Institute study indicated
carcinogenic propensities of some but not all 2 , 4 - D esters. The
thorough 1 testing of i s o m e r s , e s t e r s , s a l t s j and 'related compounds is
a very large and expensive task. Nevertheless, information about a
potential health h a z a r d may be incomplete unless all of the compounds 1
to be used are tested.
.
. .

�II.

INTRODUCTION

In 1964, The National Cancer Institute "undertook through a
-contract a s c r e e n i n g ' s t u d y " of a number of pesticidal chemicals. .
Among the r e s u l t s of this s c r e e n i n g study was the .finding that birth
defects could be provoked experimentally in rats and mice by the •
administration of relatively large doses of the herbicide, 2 , 4 , 5-T.
By the time t h e a d results were reported, 2, 4, 5-T had been in common
"use as'Sn herbicrd-e for more than 20 years. Further, it had been .
employed along v.ith 2, 4-D as a defoliant in Vietnam since 1962
although in sizeable quantities only since 1967.
In October. 1969 several agencies of Government moved in
a coordinatedjocuiainer to bring about r e s t r i c t i o n of th'e use of 2 , 4 , 5-T
both within the United States and abroad,, &gt;. In terms of domestic
agricultural use, restriction was placed on the use of 2, 4, 5-T on
food crops pending the acquisition of f u r t h e r information that might
permit the Food 'and D r u g Administration to grant a t o l e r a n c e . Use
as a defoliant in Vietnam was restricted to non-populated areas.
•For a number of reasons, it seemed wise to explore this
issue in some detail. . The most important of these r e a s o n s , p e r h a p s ,
was the d e s i r e to examine the scientific evidence available to stand
behind future policies governing the use of 2, 4, 5-T and to suggest
'directions for f u r t h e r experimental research. Accordingly, a panel
of experts was assembled by the P r e s i d e n t ' s Science A d v i s e r to
consider a. number of a s p e c t s of a variety of herbicides some of .
which were used as defoliants in Vietnam. The present report
represents~their review of 2, 4, 5-T.
'
This review considers topics which are of concern to those who
are f a c e d with policy decisions for 2, 4, 5-T. We hope that it can
serve as an example for the consideration of the health effects and
safety of pesticides and other chemical's purposefully placed in the
environment.
A number of issues are raised when the utility and safety of
an already existing material is questioned. It is elementary but
nevertheless t r u e to say that the issues are complex. In a way, their
examination can b e - c o m p a r e d to following a seemingly endless and
continuously branching program. The subject of how much assurance
of safety should be afforded is important.

�11-2

Teratogcncsis a p p e a r s to be a m o r e m a n a g e a b l e problem
than some other health effects (such.as tumor production). Prediction of safety can p r o b a b l y be made with reasonable a s s u r a n c e .
In addition, e x p e r i m e n t s to test a suspected substance are r e a s o n ably straightforward to conduct.
%

•

r

Among other problems, the purity of the chemical became an
issue. In the case of 2, 4, 5-T, separation of biological e f f e c t s of
the principal m a t e r i a l f r o m those of the impurities t u r n e d out to
have unusual importance. For this reason, the resolutio.n and
accuracy of analytic methods available and used to detect 2, 4, 5-T
and its impurities had to be evaluated. In_a_s certain ing the probabj._e
hajtjard to-jnar. of a n _ a g r i c u l t u r a l chcmical, its toxicity in absolute
terms must be r e l a t e d to the probabilities of human exposure.
Residue information on 2,4, 5-T therefore was explored.
Finally, there remains a series of policy questions which are
at least as philosophical as they are technical, the most crucial one
being how wide a margin of safety should a society adopt for itself.
The panel also touched on a n a r r o w e r aspect of-this question
by posing an additional one. This is the practical problem, in the
case of a material already in use, of how the Government should a c t .
in the interim between the time of acquisition of preliminary experimental data which reveal a chemical suspect and the performance of
more definitive experiments which establish the risk..

�II-3

REFERENCES

(1)

Press Release on 2, 4, 5-T. Office of Science and
Technology,''October 29. 1969.

I \.

�SECTION i l l
CHEMISTRY

A'.

Synthesis

B.

Formulation

C.

Solubilities

D.

Purity of Technical Grade Material

E.

. .'
- •
.

' Analytic Methods
1. Standard Procedures
2. Bound Residues

F.

Chemical Stability of 2, 4 , 5 - T
' 1.
•
• ..- ._

.

Photochemical Degradation-

2.
:

Hydrolysis

3.

Thermal Stability

4.

Biochemical Degradation

�' S U M M A R Y ^ - Section III" -

Chemistry

2 , 4 , 5 - t r i c h l o r o p h e n o x y acetic acid is produced commercially
by a process which begins with tetrachlorobenzene as starting material. Technical g r a d e 2, 4, 5-T is 90-92% pure acid. One of the •
important i m p u r i t i e s , a polychlorinated dioxin, results both f r o m
impurities in the s t a r t i n g material and as side products of the desired
reaction. A large number of e s t e r s and amine salts of 2,4, 5-T have
been developed as well as a variety of formulations in o r d e r to derive
specific p r o p e r t i e s of volatility and solubility. About one-half of
this total production can be accounted for by the 2, 4, 5-T acid and its
n-butyl ester. The f r e e acid is practically insoluble in water and,
•generally, the e s t e r s are slightly soluble. The amine salts tend to •
be more soluble. Among other things, penetration into the soil or
leaching is a.function of water solubility.
In general, 2, 4, 5-T residues can be expected to be relatively
unstable materials in the environment. They are broken down by
microbial action and by sunlight and esters are readily hydrolyzed
to the f r e e acid. Available analytic methods for detecting residues
are quite sensitive. The sensitivity o f - g a s chromatography with
microcoulometric detection is about 0. 01 ppm (10 ppb). Detection
of residues in plant material appears to be uncomplicated by bound
or complexed residues with; the possible exception of residues in the
peels of citrus fruits.
•

�</text>
                  </elementText>
                </elementTextContainer>
              </element>
            </elementContainer>
          </elementSet>
        </elementSetContainer>
      </file>
    </fileContainer>
    <collection collectionId="30">
      <elementSetContainer>
        <elementSet elementSetId="1">
          <name>Dublin Core</name>
          <description>The Dublin Core metadata element set is common to all Omeka records, including items, files, and collections. For more information see, http://dublincore.org/documents/dces/.</description>
          <elementContainer>
            <element elementId="50">
              <name>Title</name>
              <description>A name given to the resource</description>
              <elementTextContainer>
                <elementText elementTextId="4687">
                  <text>Alvin L. Young Collection on Agent Orange</text>
                </elementText>
              </elementTextContainer>
            </element>
            <element elementId="41">
              <name>Description</name>
              <description>An account of the resource</description>
              <elementTextContainer>
                <elementText elementTextId="49809">
                  <text>&lt;p style="margin-top: -1em; line-height: 1.2em;"&gt;The Alvin L. Young Collection on Agent Orange comprises 120 linear feet and spans the late 1800s to 2005; however, the bulk of the coverage is from the 1960s to the 1980s and there are many undated items. The collection was donated to Special Collections of the National Agricultural Library in 1985 by Dr. Alvin L. Young (1942- ). Dr. Young developed the collection as he conducted extensive research on the military defoliant Agent Orange. The collection is in good condition and includes letters, memoranda, books, reports, press releases, journal and newspaper clippings, field logs and notebooks, newsletters, maps, booklets and pamphlets, photographs, memorabilia, and audiotapes of an interview with Dr. Young.&lt;/p&gt;&#13;
&lt;p&gt;For more about this collection, &lt;a href="/exhibits/speccoll/exhibits/show/alvin-l--young-collection-on-a"&gt;view the Agent Orange Exhibit.&lt;/a&gt;&lt;/p&gt;</text>
                </elementText>
              </elementTextContainer>
            </element>
          </elementContainer>
        </elementSet>
      </elementSetContainer>
    </collection>
    <itemType itemTypeId="1">
      <name>Text</name>
      <description>A resource consisting primarily of words for reading. Examples include books, letters, dissertations, poems, newspapers, articles, archives of mailing lists. Note that facsimiles or images of texts are still of the genre Text.</description>
      <elementContainer>
        <element elementId="52">
          <name>Box</name>
          <description>The box containing the original item.</description>
          <elementTextContainer>
            <elementText elementTextId="48371">
              <text>197</text>
            </elementText>
          </elementTextContainer>
        </element>
        <element elementId="53">
          <name>Folder</name>
          <description>The folder containing the original item.</description>
          <elementTextContainer>
            <elementText elementTextId="48373">
              <text>5557</text>
            </elementText>
          </elementTextContainer>
        </element>
        <element elementId="54">
          <name>Series</name>
          <description>The series number of the original item.</description>
          <elementTextContainer>
            <elementText elementTextId="48376">
              <text>Series VIII Subseries II</text>
            </elementText>
          </elementTextContainer>
        </element>
      </elementContainer>
    </itemType>
    <elementSetContainer>
      <elementSet elementSetId="1">
        <name>Dublin Core</name>
        <description>The Dublin Core metadata element set is common to all Omeka records, including items, files, and collections. For more information see, http://dublincore.org/documents/dces/.</description>
        <elementContainer>
          <element elementId="39">
            <name>Creator</name>
            <description>An entity primarily responsible for making the resource</description>
            <elementTextContainer>
              <elementText elementTextId="48369">
                <text>MacLeod, Colin M.</text>
              </elementText>
              <elementText elementTextId="48370">
                <text>et al.</text>
              </elementText>
            </elementTextContainer>
          </element>
          <element elementId="41">
            <name>Description</name>
            <description>An account of the resource</description>
            <elementTextContainer>
              <elementText elementTextId="48372">
                <text>&lt;strong&gt;Corporate Author: &lt;/strong&gt;Panel on Herbicides, President's Science Advisory Committee</text>
              </elementText>
            </elementTextContainer>
          </element>
          <element elementId="40">
            <name>Date</name>
            <description>A point or period of time associated with an event in the lifecycle of the resource</description>
            <elementTextContainer>
              <elementText elementTextId="48374">
                <text>1970-07-01</text>
              </elementText>
            </elementTextContainer>
          </element>
          <element elementId="50">
            <name>Title</name>
            <description>A name given to the resource</description>
            <elementTextContainer>
              <elementText elementTextId="48375">
                <text>Report on 2,4,5-T</text>
              </elementText>
            </elementTextContainer>
          </element>
        </elementContainer>
      </elementSet>
    </elementSetContainer>
    <tagContainer>
      <tag tagId="2">
        <name>ao_seriesVIII</name>
      </tag>
    </tagContainer>
  </item>
  <item itemId="6504" public="1" featured="0">
    <fileContainer>
      <file fileId="2319">
        <src>https://www.nal.usda.gov/exhibits/speccoll/files/original/d205ca78ad089482ff3793305792b3eb.pdf</src>
        <authentication>3807b98f708558d9a6bf31a1091fa8bb</authentication>
        <elementSetContainer>
          <elementSet elementSetId="4">
            <name>PDF Text</name>
            <description/>
            <elementContainer>
              <element elementId="60">
                <name>Text</name>
                <description/>
                <elementTextContainer>
                  <elementText elementTextId="64268">
                    <text>Item D Number

05526

Author

Stanley, John S.

Corporate Author

D

Midwest Research Institute

RBDOTt/ArtiClO Tltb Analysis for Polychlorlnated Dlbenzo-p-DioxIns (PCDD)
and Dibenzofurans (PCDF) in Human Adipose Tissue:
Method Evaluation Study: Final Report with attached
letter transmitting the report to Alvin L Young, from
Janet C. Remmers, Field Studies Branch, Exposure
Evaluation Division, United States Environmental
Protection Agency

Journal/Book Title
Year

1986

Month/Day

October

Color

D

Number of Images

149

DUSCrbtOn NOtBI

EPA Prime

Contract No. 68-02-3938, Work Assignment No.
46, MRI Project No. 8501-A(46). See Item 5522 for draft
version

Tuesday, March 19, 2002

Page 5526 of 5611

�UNITED STATES ENVIRONMENTAL PROTECTION AGENCY
WASHINGTON, D.C. 20460

JAN I 3 1987
OFFICE OF
PESTICIDES AND TOXIC SUBSTANCES

A l v i n Young, P h . D . ,
Lt. Col. , USAF
Senior Policy Analyst for Life Sciences
Executive Office of the President
Office of Science and Technology Policy
Room 5005
New Executive Office Building
Washington, DC 20506
Dear Dr. Young:
Enclosed for your information is the final report entitled
"Analysis for Polychlorinated Dibenzo-p_-dioxins (PCDD) and
Dibenzofurans (PCDF) in Human Adipose Tissue: Method Evaluation
Study."
Sincerely,

Janet C. Remmers
Field Studies Branch
Exposure Evaluation Division
(TS-798)
Enclosure

�United Stale-.
Environment'*!
Aqency
Toxic Sub.itan

&amp;EPA

ANALYSIS FOR
POLY-CHLORINATED
DIBENZO-p-DIOXINS (PCDD)
AND DIBENZOFURANS (PCDF)
IN HUMAN ADIPOSE TISSUE:
METHOD EVALUATION STUDY

80t-

C

o
co
w
*C
0)

o
C

o
o
TJ

C
3
O

95% Confidence Limits
for Individual Analyses
2, 3, 7, 8-TCDD
I

I

50
Spiked Concentration (pg/g)

�ANALYSIS FOR POLYCHLORINATED DIBENZO-£-DIOXINS (PCDD) AND DIBENZOFURANS (PCDF)
IN HUMAN ADIPOSE TISSUE: METHOD EVALUATION STUDY

by
John S. Stanley, Randy E. Ayling, Karin M. Bauer, Michael J. McGrath,
Thomas M. Sack, and Kelly R. Thornburg

FINAL REPORT

EPA Prime Contract No. 68-02-3938
Work Assignment No. 46
MRI Project No. 8501-A(46)

and
EPA Prime Contract No. 68-02-4252
Work Assignment No. 24
MRI Project No. 8824-A(01)

Field Studies Branch, TS-798
Office of Toxic Substances
U.S. Environmental Protection Agency
401 M Street, S.W.
Washington, DC 20460
Attn: Ms. Janet Remmers, Work Assignment Manager
Dr. Joseph J. Breen, Project Officer

�DISCLAIMER

This document has been reviewed and approved for publication by the
Office of Toxic Substances, Office of Pesticides and Toxic Substances, U.S.
Environmental Protection Agency. The use of trade names or commercial products does not constitute Agency endorsement or recommendation for use.

�PREFACE
This report provides a summary of the results from a method evaluation study for the determination of 2,3,7,8-substituted polychlorinated
dibenzo-p_-dioxins (PCDD) and dibenzofurans (PCDF) in human adipose tissues
at the parts-per- trill ion (ppt) level. This method evaluation is an integral
part of a collaborative program between the U.S. Environmental Protection
Agency's Office of Toxic Substances and the Veterans Administration to determine if significant differences exist in the 2,3,7,8-substituted PCDD and/or
PCDF levels in human adipose tissues for Vietnam veterans compared to the
general adult male population. The study design will focus on specimens
within EPA's National Human Adipose Tissue Survey (NHATS) repository. The
method evaluation described in this report was necessary to establish method
performance (accuracy and precision) before proceeding with actual sample
analysis.
This method evaluation study was completed under EPA Contract Nos.
68-02-4252, Work Assignment 24 and 68-02-3938, Work Assignment 46, "Analysis
for Dioxins and Furans in Human Adipose Tissue," Ms. Janet Remmers, Work
Assignment Manager, and Dr. Joseph Breen, Project Officer.
MIDWEST RESEARCH INSTITUTE

aul C. Constant
Program Manager
Approved:

Jack Balsinger^
Quality Assurance Coordinator

JoMi E. Going, Director
Chemical Sciences Department

October 30, 1986

m

�TABLE OF CONTENTS

I.

Introduction

1

II.

Summary

3

III.

Recommendations

4

IV.

Experimental

5

A. Preparation of Homogenized Tissue
B. Analytical Standards
1. Calibration Standards
2. Spiking Solutions

5
5
6
6

C. Analytical Procedure

10

D.

12

HRGC/MS Analysis

E. Data Interpretation
1. Qualitative
2. Quantitation
F. Quality Assurance/Quality Control (QA/QC)
G. Preliminary Method Studies
1. Gravimetric Studies
2. Carbon-14 Recovery Studies
V.

Results

23

A. Analytical Results
B. Statistical Analysis
1.

Recovery of Internal Quantitation Standards. .

2. Estimation of Background Levels of PCDDs and
PCDFs
3. Day-to-Day HRGC/MS Analysis Precision
VI.

Quality Assurance/Quality Control (QA/QC)
A. Initial Calibration
B. Daily Verification of Response Factors
C. Blanks
D.

17
17
17
20
20
21
21

23
23
57

57
59
63
63
65
65

Absolute Recoveries of the Internal Quantitation

Standards

77

VII.

Glossary of Terms

82

VIII.

References

84

Appendix A - Analytical Protocol for Determination of PCDDs and
PCDFs in Human Adipose Tissue

A-l

�LIST OF FIGURES
Figure
1

2

3

4

5

6

7

8

9

10

11

12

Page
Comparison of the HRGC/MS-SIM reconstructed ion chromatogram (RIC) from the analysis of unspiked homogenized
human adipose tissue matrix and a calibration standard
for PCDDs and PCDFs

30

Example of the TCDF (m/z 304) and TCDD (m/z 320)
HRGC/MS-SIM elution profiles in unspiked and spiked
human adipose

31

Example of the PeCDF (m/z 338) and PeCDD (m/z 354)
HRGC/MS-SIM elution profiles in unspiked and spiked
human adipose

32

Example of the HxCDF (m/z 374) and HxCDD (m/z 390)
HRGC/MS-SIM elution profiles in unspiked and spiked
human adipose

33

Example of the HpCDF (m/z 408) and HpCDD (m/z 424)
HRGC/MS-SIM elution profiles in unspiked and spiked
human adipose

34

Examples of the OCDF (m/z 442) and OCDD (m/z 458)
HRGC/MS-SIM elution profiles in unspiked and spiked
human adipose

35

Measured concentrations versus concentrations of 2,3,7,8TCDD spiked into the homogenized human adipose lipid
matrix

36

Measured concentrations versus concentrations of
1,2,3,7,8-PeCDD spiked into the homogenized human
adipose lipid matrix

37

Measured concentrations versus concentrations of
1,2,3,4,7,8-HxCDD spiked into the homogenized human
adipose lipid matrix

38

Measured concentrations versus concentrations of
1,2,3,6,7,8-HxCDD spiked into the homogenized human
adipose lipid matrix

39

Measured concentrations versus concentrations of
1,2,3,7,8,9-HxCDD spiked into the homogenized human
adipose lipid matrix

40

Measured concentrations versus concentrations of
1,2,3,4,6,7,8-HpCDD spiked into the homogenized human
adipose lipid matrix

41

�LIST OF FIGURES (continued)
Figure
13
14

15

16

17

18

19

20

21

22

23
24

25

Page
Measured concentrations versus concentrations of OCDD
spiked into the homogenized human adipose lipid matrix. .

42

Measured concentrations versus concentrations of
2,3,7,8-TCDF spiked into the homogenized human
adipose lipid matrix

43

Measured concentrations versus concentrations of
1,2,3,7,8-PeCDF spiked into the homogenized human
adipose lipid matrix

44

Measured concentrations versus concentrations of
2,3,4,7,8-PeCDF spiked into the homogenized human
adipose lipid matrix

45

Measured concentrations versus concentrations of
1,2,3,4,7,8-HxCDF spiked into the homogenized human
adipose lipid matrix

46

Measured concentrations versus concentrations of
1,2,3,6,7,8-HxCDF spiked into the homogenized human
adipose lipid matrix

47

Measured concentrations versus concentrations of
2,3,4,6,7,8-HxCDF spiked into the homogenized human
adipose lipid matrix

48

Measured concentrations versus concentrations of
1,2,3,7,8,9-HxCDF spiked into the homogenized human
adipose lipid matrix

49

Measured concentrations versus concentrations of
1,2,3,4,7,8,9-HpCDF spiked into the homogenized human
adipose lipid matrix

50

Measured concentrations versus concentrations of
l,2,3,4,6,7,8~HpCDF spiked into the homogenized human
adipose lipid matrix

51

Measured concentrations versus concentrations of OCDF
spiked into the homogenized human adipose lipid matrix. .

52

Method accuracy estimates as determined from the slopes
of the least squares regression lines for the 17
target PCDD and PCDF analytes

54

Control charts showing response factors by date for
2,3,7,8-TCDF and 2,3,7,8-TCDD

66

VII

�LIST OF FIGURES (continued)
Figure
26
27
28
29
30
31
32
33
34

Page
Control charts showing response factors by date for
1,2,3,7,8-PeCDF and 2,3,4,7,8-PeCDF

67

Control chart showing response factors by date for
1,2,3,7,8-PeCDD

68

Control charts showing response factors by date for
1,2,3,4,7,8-HxCDF and 1,2,3,6,7,8-HxCDF

69

Control charts showing response factors by date for
2,3,4,6,7,8-HxCDF and 1,2,3,7,8,9-HxCDF

70

Control charts showing response factors by date for
1,2,3,4,7,8-HxCDD and 1,2,3,6,7,8-HxCDD

71

Control chart showing response factors by date for
1,2,3,7,8,9-HxCDD

72

Control charts showing response factors by date for
1,2,3,4,6,7,8-HpCDF and 1,2,3,4,7,8,9-HpCDF

73

Control chart showing response factors by date for
1,2,3,4,6,7,8-HpCDD

74

Control charts showing response factors by date for OCDF
and OCDD

75

v i ii

�LIST OF TABLES
Table
1

Page
Analytical Standards Available for the Method
Evaluation Studies

7

2

Concentration Calibration Solutions

8

3

Native PCDD and PCDF Spiking Solution

9

4

Internal Standard Spiking Solutions

11

5

HRGC/LRMS Operating Conditions for PCDD/PCDF Analysis . . .

13

6

Ions Monitored for HRGC/MS Analysis of PCDD/PCDF

14

7

Typical Daily Sequence for PCDD/PCDF Analysis

16

8

Ion Ratios for HRGC/MS Analysis of PCDD/PCDF

18

9

Summary of the Results of the Sample Preparation Method
Evaluation Using Carbon-14 PCDDs

22

Spiked Versus Measured Concentrations of 2,3,7,8-TCDF
and 2,3,7,8-TCDD in Homogenized Human Adipose Lipid
Samples

24

Spiked Versus Measured Concentrations of 1,2,3,7,8-PeCDF,
2,3,4,7,8-PeCDF, and 1,2,3,7,8-PeCDD in Homogenized
Human Adipose Tissue Samples

25

Spiked Versus Measured Concentrations of 1,2,3,4,7,8-;
1,2,3,6,7,8-; 2,3,4,6,7,8-; and 1,2,3,7,8,9-HxCDF
in Homogenized Human Adipose Lipid Matrix

26

Spiked Versus Measured Concentration of 1,2,3,4,7,8-;
1,2,3,6,7,8-; and 1,2,3,7,8,9-HxCDD in Homogenized
Human Adipose Lipid Samples

27

Spiked Versus Measured Concentrations of 1,2,3,4,6,7,8HpCDF, 1,2,3,4,7,8,9-HpCDF, and 1,2,3,4,6,7,8-HpCDD
in Homogenized Human Adipose Lipid Samples

28

Spiked Versus Measured Concentrations of OCDF and OCDD
In Homogenized Human Adipose Lipid Samples

29

16

Regression Line Slopes with 95% Confidence Limits

55

17

Results of the Analysis of the Low and High Level
Native Spike Solutions

56

10

11

12

13

14

15

IX

�LIST OF TABLES (continued)
Table

Page

18

Background Level Estimates with 95% Confidence Limits . . .

58

19

Day-to-Day Precision of Analysis of Specific Sample
Extracts for Tetra- and Pentachloro PCDF and PCDD . . . .

60

Day-to-Day Precision of Analysis of Specific Sample
Extracts for Hexa- and Heptachloro PCDF and PCDD

61

Day-to-Day Precision of Analysis of Specific Sample
Extracts for OCDF and OCDD

62

Relative Response Factors (Grand Means) Determined from
Multipoint Concentration Calibration Standards

64

Summary of Results from the Analysis of a Laboratory
Method Blank

76

Recovery of Radiolabeled PCDDs from Precleaned Activated
Alumina

78

Absolute Recoveries of the Internal Quantitation Standards
from the Human Adipose Lipid Matrix

79

Recovery of Carbon-14 Labeled 2,3,7,8-TCDD, 1,2,3,4,7,8HxCDD, and OCDD as a Function of Final Concentration
Conditions

81

20
21
22
23
24
25
26

�I.

INTRODUCTION

The Environmental Protection Agency Office of Toxic Substances
(EPA/OTS) and the Veterans Administration (VA) have established an interagency
agreement to study the level of polychlorinated dibenzo-£-dioxins (PCDDs) and
dibenzofurans (PCDFs) in human adipose tissues. The occurrence and levels of
PCDDs and PCDFs with chlorine substitution in the 2,3,7,8 positions (especially
2,3,7,8-TCDD) of the parent molecules are of primary interest.
As part of this interagency effort, it has been proposed to use
selected adipose tissue samples that were collected for the Field Studies
Branch (FSB) of EPA's Office of Toxic Substances (OTS) through the National
Human Adipose Tissue Survey (NHATS) to determine exposure to PCDDs and PCDFs.
The available adipose tissues include specimens obtained from young men whose
age indicates that they could have served in Vietnam and could have been exposed to Agent Orange. The tissues were originally collected as part of a
broadly based and statistical random sampling of the continental United States.
The analysis of these tissues may provide information on the differences of
exposure of the general adult male population and Vietnam veterans to the
2,3,7,8-substituted PCDDs and PCDFs.
The overall objectives of the proposed EPA/VA collaborative studies

are:
1.

Evaluate the reliability, accuracy, precision, and sensitivity of a proposed method for the determination of 2,3,7,8substituted PCDDs and PCDFs (tetra- through octachloro
homologs) in human adipose tissue at the parts-per-tri1 lion
(ppt) level.

2.

Determine if these compounds can be detected in adipose tissues
of the American male adult population; and

3.

Determine if individuals with military service in Vietnam have
significantly different levels of 2,3,7,8-substituted PCDDs
and PCDFs (particularly 2,3,7,8-TCDD) than other American men.

As a prelude to this work assignment, MRI conducted an extensive
literature review of applicable analytical methods and conducted a meeting
with recognized experts in this field to identify critical aspects of analytical methodology.1'2
Based on the information gathered through the literature review and
the meeting with the recognized experts, a special report was prepared for
OTS proposing a framework for an analytical method for analysis of human adipose tissues.3 Several studies have been completed since the issuance of that
report which reflect the advances in analytical techniques for adipose tissue
analysis.4 16 The salient features of these methods have been combined into
a single protocol for the routine analysis of tetra- through octachloro PCDDs
and PCDFs at the low-parts-per-tril1 ion level for the EPA/VA tissue study.
This report focuses on a method evaluation study that was conducted
to achieve the first objective of the interagency agreement. Clarification

�of method performance is necessary before proceeding with the analysis of
actual samples retrieved from the NHATS repository.
This report includes a summary of the method evaluation study results (Section II). Recommendations to be implemented before proceeding with
the actual tissue samples from the NHATS repository are presented in Section
III. A description of the actual experimental procedures is provided in Section IV. Results of sample analyses are summarized in Section V, and quality
assurance/quality control (QA/QC) aspects of the study are detailed in Section
VI. Pertinent references are listed in Section VII. Appendix A contains the
detailed analytical protocol that will be followed for the analysis of the
NHATS specimens designated in the study design to be provided by EPA/VA.

�II.

SUMMARY

The results of the replicate analysis of spiked and unspiked homogenized human adipose tissue matrix demonstrate that the analytical method
produces accurate and precise data for 17 specific 2,3,7,8-substituted PCDD
and PCDF (tetra- through octachloro homologs) compounds. Accuracy of the
analytical method was demonstrated to range from 90 to 120% for the 17
2,3,7,8-substituted PCDD and PCDF compounds. Data are reported for three or
four replicate analyses of samples spiked at three different concentration
levels. The endogenous or background levels of the PCDD and PCDF congeners
in the homogenized adipose lipid matrix were estimated through regression
analyses of measured (found) versus spiked concentrations for each compound.
The analytical method is capable of providing quantitative data for
tetra- through octachloro PCDD and PCDF congeners to concentration levels as
low as 1 pg of the tetrachloro congeners per gram of adipose tissue. However,
an interference was noted at m/z 304 which coeluted with 2,3,7,8-TCDF, resulting in a detection level of approximately 4 pg/g.
Average absolute recoveries of the internal quantisation standards
ranged from 52% for 13C12-TCDD up to 89% for 13C12-OCDD. The agreement of
the measured concentrations versus the spiked concentrations for each PCDD
and PCDF congener demonstrates that the internal standard quantitation procedure provides an accurate measure of concentration which is independent of
the absolute recovery.
Final concentration conditions were noted to have pronounced effect
on the absolute recoveries of the lower chlorinated compounds, particularly
2,3,7,8-TCDD. Experiments with carbon-14 labeled 2,3,7,8-TCDD demonstrated
that final concentration at temperatures of 55 to 60°C resulted in recoveries
as low as 54% while the same procedure conducted at ambient conditions resulted in greater than 90% recovery.
Analysis of method and reagent blanks provided information on potential artifacts in the sample preparation scheme. Additional experiments
were conducted with carbon-14 labeled PCDDs to evaluate the cleanup efficiency
and recovery of PCDDs from chromatographic materials, particularly acidic
alumina.

�III.

RECOMMENDATIONS

Some minor modifications have been made in the written protocol
(Appendix A) that were not included in this phase of the method validation.
These include:
a cleanup procedure for activated acidic alumina prior to
fractionation of sample extracts to remove artifacts; and
final concentration of the sample extracts using nitrogen
blowdown at room temperature rather than heating to 55-60°C.
The spiking solutions used to prepare the spiked quality control
samples should be submitted for replicate (minimum of three/per spike level)
HRGC/MS analysis to assist the interpretation of positive or negative bias in
the accuracy of QC sample data.
The accuracy bounds should be extended to 50-130% from 50-115% as
specified in the draft quality assurance program plan.
The method should include additional internal quantitation standards
to pair with the HpCDF 13 OCDF congeners. Also, an additional internal recovand
ery standard, possibly C12-l,2,3,4,7,8-HxCDD, is required to provide better
estimates of absolute method recovery. These additional compounds, if available, will be incorporated into the method before initiating sample analyses.
Analysis for 2,3,7,8-TCDF may require high resolution mass spectrometry to avoid interferences occurring at m/z 304. This will require
modification of the HRGC/HRMS portion of the protocol to include the specific acquisition parameters for the characteristic ions of 2,3,7,8-TCDF.

�IV. EXPERIMENTAL
A.

Preparation of Homogenized Tissue

A bulk lipid sample was prepared from the extracts of human adipose
tissue samples collected through the NHATS program. The adipose tissue samples have been stored in a deep freezer at approximately -10°C since collection. The homogenized tissue extract or bulk lipid was used in this method
evaluation study for preparation of replicate samples spiked with varying
levels of specific PCDD and PCDF isomers. This homogenized matrix will also
be used for preparing control and spiked quality control samples for the
actual NHATS sample analysis phase of the program.
A total of 2,465 g of adipose tissue was extracted, dried, and
concentrated to yield 1,652 g (62% of original weight) of homogenized lipid.
Specific procedures for preparing this matrix are described below.
The adipose tissue samples were thawed at room temperature for 1 to
2 h. Portions of the samples were added to a blender cup of a Waring® blender
and covered with methylene chloride. The volume of methylene chloride was
approximately equal to the sample volume (100 to 200 ml). This mixture was
blended at high speed for approximately 10 min, and the contents were transferred to a 500-mL Erlenmeyer flask and further blended with a Tekmar®
Tissumizer, also at high speed for 10 min. A powder funnel was plugged with
a wad of glass wool (silanized, methylene chloride extracted) and filled with
•v 50 g of sodium sulfate (heated overnight to 600°C in a muffle furnace).
The sodium sulfate was wetted with methylene chloride prior to elution of the
sample extract. The dried effluents were refiltered in the same way using a
fresh bed of sodium sulfate to remove particulate and residual water.
The samples were transferred to 1-L round bottom flasks, and the
solvent was removed by rotary evaporation. The water bath on the rotary evaporator was kept at 60°C using a thermostatted heating element. Once the solvent appeared to have been removed (constant volume in flask, no visible condensation in condenser), the heating and evaporation process was continued
for at least 2 h. The flask and contents were removed and stored in a refrigerator. The extracted lipid solidified upon refrigeration and was visually
checked for homogeneity. No precipitates or phase separation was observed.
The lipid residue was allowed to liquify at room temperature and was transferred to a 4-L glass bottle with a Teflon®-!ined lid.
The lipid residue was brought to room temperature and heated just
enough to allow the lipid to achieve an oily state prior to aliquotting portions for the method evaluation studies.
B.

Analytical Standards

Analytical standards including native PCDD and PCDF congeners,
stable isotope (carbon-13) labeled standards and radiolabeled (carbon-14)
standards were purchased from Cambridge Isotope Laboratories, Woburn,
Massachusetts, and Pathfinder Laboratories, St. Louis, Missouri. The 2,3,7,8TCDD was received from the EPA Reference Materials Branch as a solution in

�isooctane. The other native PCDD and PCDF congeners were received as 1-mg
neat standards. The stable and radiolabeled isotopes were received as solutions in n-nonane or isooctane and toluene, respectively. Table 1 provides a
summary of the standards used for this study.
Stock solutions of the individual PCDD and PCDF congeners were prepared from the neat standards. The neat materials were weighed using a Cahn
27 electrobalance calibrated versus a 1-mg (Class M) standard. The neat compounds were transferred to glass vials and were dissolved in 2.0 to 3.0 mL of
toluene (Burdick and Jackson, distilled in glass). Toluene was added to each
standard using volumetric pipettes (Class A). The OCDD required dilution to
10.0 ml using a 50:50 mixture of toluene and anisole.
A working solution consisting of the 17 native PCDD and PCDF congeners was prepared in toluene at a concentration of 2 (J9/mL for the TCDD,
TCDF, PeCDD, and PeCDF congeners, 5 ug/mL for the HxCDD, HxCDF, HpCDD, and
HpCDF congeners, and 10 ug/mL for the OCDD and OCDF. The working solution
was used to prepare both the lipid matrix spiking solution and the calibration standards.
The stable isotope labeled internal standards were obtained as solutions13in n-nonane or isooctane at 50 ug/mL concentration with the exception
of the C12-OCDD, which was provided at 10 ug/mL. Separate working solutions
containing mixtures of the carbon-13 labeled PCDDs and PCDFs were prepared in
isooctane for use in the calibration standards and the sample spiking solutions.
The carbon-14 radiolabeled PCDDs were used for preliminary method
evaluation studies. The specific activity of the 14C-2,3,7,8-TCDD (117.56
mCi/mmole) was high enough to allow recovery studies at spike levels equivalent to 10 pg/g for a 10-g sample.

1. Calibration Standards
Eight concentration calibration standards containing the 17 native
and the 9 carbon-13 labeled internal standards were prepared for determining
the consistency of response factors for the native PCDDs and PCDFs versus the
corresponding carbon-13 congeners. Table 2 presents a summary of the calibration standards prepared for the method calibration study. The solution concentrations (pg/pL) can also be considered as equivalent to residue levels in
picograms per gram of adipose. For example, a 1 pg/uL concentration standard
corresponds to a tissue concentration of 1 pg of PCDD or PCDF congener per
gram of adipose assuming a 10-g sample is available for analysis.
2. Spiking Solutions
a. Native PCDD and PCDF
A solution containing the 2,3,7,8-substituted PCDD and PCDF
congeners was prepared in isooctane for spiking the homogenized lipid materials for the method evaluation study. Table 3 specifies the levels of
each of the native PCDD and PCDF congeners present in this solution.

�Table 1. Analytical Standards Available for the Method Evaluation Studies
Source

Compound
Native
2,3,7,8-TCDD
2,3,7,8-TCDF
1,2,3,7,8-PeCDD
1,2,3,7,8-PeCDF
2,3,4,7,8-PeCDF
1,2,3,4,7,8-HxCDD
1,2,3,6,7,8-HxCDD
1,2,3,7,8,9-HxCDD
1,2, 3,4,7, 8-HxCDF
1,2,3,6,7,8-HxCDF
1,2,3,7,8,9-HxCDF
2,3,4,6,7,8-HxCDF
1,2,3,4,6,7,8-HpCDD
1,2,3,4,6,7,8-HpCDF
1,2,3,4,7,8,9-HpCDF
OCDD
OCDF

EPA QA Reference Materials
Branch
Cambridge Isotope Laboratories
Cambridge Isotope Laboratories
Cambridge Isotope Laboratories
Cambridge Isotope Laboratories
Cambridge Isotope Laboratories
Cambridge Isotope Laboratories
Cambridge Isotope Laboratories
Cambridge Isotope Laboratories
Cambridge Isotope Laboratories
Cambridge Isotope Laboratories
Cambridge Isotope Laboratories
Cambridge Isotope Laboratories
Cambridge Isotope Laboratories
Cambridge Isotope Laboratories
Cambridge Isotope Laboratories
Cambridge Isotope Laboratories

Lot/Code

20603
AWN 1203-74/EF-903C
MLB-706-53/ED-950C
AWN-729-21/EF-953C
AWN-729-45/EF-956C
830244/ED-961C
MLB-706-47/ED-960C
MLB-706-73/ED-969C
AWN-729-20/EF-964C
MB 13106-7/EF-962-C
MB 13106-47/EF-967-C
MB 13106-3/EF-968-C
MLB-706-21/ED-971C
AWN-729-22/EF-973C
MB-13-106-77/EF-975C
8465-F-982-C/EF-982C
F2832/ED-980C

13

C12-Internal stand;irds
Cambridge
2,3,7,8-TCDD
Cambridge
2,3,7,8-TCDF
1,2,3,7,8-PeCDD
Cambridge
1,2,3,7,8-PeCDF
Cambridge
Cambridge
1,2,3,6,7,8-HxCDD
Cambridge
1,2,3,4,7,8-HxCDF
1,2,3,4,6,7,8-HpCDD Cambridge
OCDD
Cambridge
37

Isotope
Isotope
Isotope
Isotope
Isotope
Isotope
Isotope
Isotope

Laboratories
Laboratories
Laboratories
Laboratories
Laboratories
Laboratories
Laboratories
Laboratories

R00208/ED-900
R00236/EF-904
R00241/ED-955
R00221/EF-952
R00249/ED-966C
R00234/EF-963C
R00248/ED-972
R00263/ED-981

Cl-Internal standaird

37

C14-1,2,3,4,6,7,8HpCDD

KOR Isotopes

580012/SSY-4-32

l4

C 12 -Radiolabeled standards
2,3,7,8-TCDD
Pathfinder Laboratories
Pathfinder Laboratories
1,2,3,4,7,8-HxCDD
OCDD
Pathfinder Laboratories
S.A. = specific activity.

S.A. = 117.56 mCi/mmole
S.A. = 24.16 mCi/mmole
S.A. = 20.50 mCi/mmole

�Table 2.

Concentration Calibration Solutions'
Concentration in calibration solutions in p flA
iL
CS1
CS2
CS3
CS4
CS5
CS6
CS7
CSS

Compound
Native

200
200
200
200
200
500
500
500
500
500
500
500
500
500
500
1 ,000
1 ,000

25

5
5
5
5
5
12. 5
12. 5
12. 5
12. 5
12. 5
12. 5
12. 5
12. 5
12. 5
12. 5
25
25

100
100
100
100
100
250
250
250
250
250
250
250
250
250
250
500
500

50
50
50
50
50
125
125
125
125
125
125
125
125
125
125
250
250

25
25
25
25
62. 5
62. 5
62. 5
62. 5
62. 5
62. 5
62. 5
62. 5
62. 5
62. 5
125
125

Internal quantitation standards
13
50
50
C12-2,3,7,8-TCDD
13
C12-2,3,7,8-TCDF
50
50
13
50
50
C12-l,2,3,7,8-PeCDD
13
C12-l,2,3,7,8-PeCDF
50
50
13
C12-l,2,3,6,7,8-HxCDD 125
125
13
C12-l,2,3,4,7,8-HxCDF 125
125
13
C12-1,2,3,4,6,7,8125
125
HpCDD
13
C12-OCDD
250
250

50
50
50
50
125
125
125

50
50
50
50
125
125
125

50
50
50
50
125
125
125

50
50
50
50
125
125
125

50
50
50
50
125
125
125

50
50
50
50
125
125
125

250

250

250

250

250

250

50

50

50

50

50

50

2,3,7,8-TCDD
2,3,7,8-TCDF
1,2,3,7,8-PeCDD
1,2,3,7,8-PeCDF
2,3,4,7,8-PeCDF
1,2,3,4,7,8-HxCDD
1,2,3,6,7,8-HxCDD
1,2,3,7,8,9-HxCDD
1,2,3,4,7,8-HxCDF
1,2,3,6,7,8-HxCDF
1,2,3,7,8,9-HxCDF
2,3,4,6,7,8-HxCDF
1,2,3,4,6,7,8-HpCDD
1,2,3,4,6,7,8-HpCDF
1,2,3,4,7,8,9-HpCDF
OCDD
OCDF

10
10
10
10
10
25
25
25
25
25
25
25
25
25
25
50
50

2. 5
2. 5
2. 5
2. 5
2. 5
6. 25
6. 25
6. 25
6. 25
6. 25
6. 25
6. 25
6. 25
6. 25
6. 25
12. 5
12. 5

1
1
1
1
1
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
5
5

Internal recovery standard
13

C12-1,2,3,4-TCDD

Prepared in tridecane.

50

50

�Table 3. Native PCDD and PCDF Spiking Solution3

Compound
2,3,7,8-TCDD
2,3,7,8-TCDF
1,2,3,7,8-PeCDD
1,2,3,7,8-PeCDF
2,3,4,7,8-PeCDF
1,2,3,4,7,8-HxCDD
1,2,3,6,7,8-HxCDD
1,2,3,7,8,9-HxCDD
1,2,3,4,7,8-HxCDF
1,2,3,6,7,8-HxCDF
1,2,3,7,8,9-HxCDF
2,3,4,6,7,8-HxCDF
1,2,3,4,6,7,8-HpCDD
1,2,3,4,6,7,8-HpCDF
1,2,3,4,7,8,9-HpCDF
OCDD
OCDF

a

Prepared in isooctane.

Concentration
(pg/pL)
5
5
5
5
5
12.5
12.5
12.5
12.5
12.5
12.5
12.5
12.5
12.5
12.5
25
25

�b.

Internal Standards

Two different internal standard spiking solutions were prepared
for quantitation of native PCDD and PCDF congeners. The compositions of each
of the spiking solutions are presented in Table 4. The internal quantitation
standards were spiked into the lipid aliquots prior to any cleanup procedures
and hence were carried throughout the method exactly as the corresponding
native congeners. The internal recovery standard was added in 10 uL of a
keeper solution (tridecane) during final extract concentration prior to analysis. The recovery standard was used to measure the absolute method recoveries
of the internal quantitation standards.
C. Analytical Procedure
The homogenized human adipose lipid matrix was allowed to come to
room temperature and then warmed in a water bath until the matrix changed to
an oily state. Approximately 10.0 g of the oily material was transferred by
pipette to preweighed glass vials, and the actual weight of the lipid was
determined to the nearest 0.01 g by difference using an analytical balance.
Four 10.00-g aliquots were spiked with 20 uL of the native spiking solution
presented in Table 3, another four aliquots were spiked with 50 (jL of the same
solution, and three additional aliquots were spiked with 100 p.L of native PCDD
and PCDF solution. These spikes were equivalent to concentrations ranging
from 10, 25, and 50 pg/g in the lipid matrix for the tetra- and pentachloro
PCDD and PCDF congeners up to 50, 125, and 250 pg/g for the OCDD and OCDF for
the low, medium, and high level spikes.
In addition to the spiked samples, three aliquots of the lipid
material were transferred for determining the endogenous levels of each of
the PCDD and PCDF congeners in the control matrix.
Each of the sample aliquots was fortified with 100 |jL of the internal quantitation standard spiking solution (Table 4). The spiked samples
were each quantitatively transferred to 500-mL Erlenmeyer flasks using hexane.
The residues were diluted with a total of 200 mL of hexane, and
100 g of sulfuric acid (H2S04) modified silica gel (40% w/w) was added to each
solution with stirring. The mixtures were stirred for approximately 2 h, and
the supernatants were decanted and filtered through filter funnels packed with
anhydrous sodium sulfate (Na2S04). The H2S04 modified silica adsorbents were
washed with at least two additional aliquots of hexane and dried by elution
through Na2S04.
The combined hexane extracts for each sample were eluted through a
column consisting of the 40% H2S04 modified silica gel (4.0 g) and silica
gel (1.0 g). The eluates were concentrated to approximately 15 mL and added
to columns of acidic alumina (Bio-Rad, AG-4, 6.0 g). The acidic alumina columns were eluted first with 20 mL of hexane, which was collected but not analyzed, followed by elution with 30 mL of 20% methylene chloride in hexane.
The PCDDs and PCDFs were eluted from the acidic alumina using the 20% methylene chloride in hexane. The PCDDs and PCDFs in the eluates were isolated from
other chlorinated planar aromatics using columns (5-mL disposable pipettes
containing 500 mg of 18% Carbopak C and Celite-545). The Carbopak C/Celite
10

�Table 4.

Internal Standard Spiking Solutions
Concentration
(pg/uL)

Compound
Internal quantisation standard
13

5

13

5

13

5

13

5

C12-2,3,7,8-TCDD

C12-2,3,7,8-TCDF
C12-l,2,3,7,8-PeCDD
C12-l,2,3,7,8-PeCDF

13

12.5

13

12.5

13

12.5

C12-l,2,3,6,7,8-HxCDD
C12-l,2,3,4,7,8-HxCDF
C12-l,2,3,4,6,7,8-HpCDD

13

C12-OCDD

25

Internal recovery standard
13

C12-1,2,3,4-TCDD

50

.Solution prepared in isooctane.
Solution prepared in tridecane.

11

�columns were pre-eluted with 2 ml of toluene, 1 mL of 75:20:5 methylene
chloride/methanol/benzene, 1 mL of 1:1 methylene chloride/cyclohexane, and
2 ml of hexane. The sample extracts (30 ml) were added to the columns, which
were eluted with 2 mL of hexane, 1 mL of 1:1 methylene chloride/cyclohexane,
and 1 mL of the 75:20:5 methylene chloride/methanol/benzene. These eluents
were collected and combined but were not analyzed. The Carbopak C/Celite
columns were turned upside down, and the PCDDs and PCDFs were eluted with
20 mL of toluene. The toluene was concentrated to less than 1 mL using flowing nitrogen and a heated water bath (55-60°C) and transferred to 1.0-mL
conical vials using a solution of 1% toluene in methylene chloride. Tridecane
(10 uL) containing 500 pg of the internal recovery standard 13C12-1,2,3,4-TCDD
was added as a keeper when the solution had concentrated to approximately
200 uL. The extracts were concentrated to final volume using nitrogen and
the heated water bath.
D.

HRGC/MS Analysis

The analyses of the spiked and unspiked lipid samples were completed
using a Kratos MS50TC double-focusing magnetic sector mass spectrometer. The
determination for the tetra- through octachloro homologs was achieved in a
single analysis using the conditions described in Table 5. Table 6 provides
the characteristic ions monitored for each PCDD and PCDF homolog. As noted
from Table 6, the analysis requires five different parameter descriptions that
were switched automatically during the course of the analysis. Parameters
monitored included two characteristic molecular ions for each PCDD and PCDF
homolog and the corresponding carbon-13 labeled internal standard. In addition, a fragment ion of perfluorokerosene (PFK), m/z 380.976, was monitored
throughout each analysis to ensure that proper mass calibration was maintained.
The parameter descriptors also included an ion characteristic of specific
homologs of chlorinated diphenyl ethers to demonstrate that responses meeting
the qualitative criteria for specific PCDF congeners were not due to these
potential interferences.
Triplicate analyses of six of the eight calibration solutions
(Table 2) were completed, and the variability in relative response factors
across this range was calculated. The analyst was required to demonstrate on
a daily basis that the relative response factors (RRF) were in agreement
within ± 20% of the established averages for 2,3,7,8-TCDD and 2,3,7,8-TCDF
and within ± 30% of the average RRF values for the other congeners. The
equation used to calculate the relative response factors for each PCDD and
PCDF congener are discussed later in this report (Section E - Data Interpretation, 2 - Quantitation, p. 17). The analyst was also required to determine
column performance by analyzing a mixture of TCDD isomers before proceeding
with sample analysis. Table 7 gives an example of the typical daily sequence
for PCDD/PCDF analysis.

12

�Table 5. HRGC/LRMS Operating Conditions for PCDD/PCDF Analysis
Mass spectrometer
8,000 V
500 MA
70 eV
-1,800 V
280°C

Accelerating voltage:
Trap current:
Electron energy:
Electron multiplier voltage:
Source temperature:
Resolution:
Overall SIM cycle time:

^ 3,000 (10% valley definition)

1s

Gas chromatograph
Column coating:
Film thickness:
Column dimensions:
He linear velocity:
He head pressure:

DB-5
0.25
60 m
•v 25
1.75

Injection type:
Split flow:
Purge flow:
Injector temperature:
Interface temperature:
Injection size:
Initial temperature:
Initial time:
Temperature program:

Splitless, 45 s
30 mL/min
6 mL/min
270°C
300°C
1-2 pL
200°C
2 min
200°C to 330°C at 5°C/min

13

(jm
x 0.25 mm ID
cm/sec
kg/cm2 (25 psi)

�Table 6.

Ions Monitored for HRGC/MS Analysis of PCDD/PCDF

Descriptor
Al

ID
TCDF
13

C12-TCDF

TCDD
13

C12-TCDD

HxCDPE
PFK (lock mass)
A2

TCDF
TCDD
PeCDF
13

C12-PeCDF

PeCDD
13

C12-PeCDD

PFK (lock mass)
HpCDPE
A3

HxCDF
PFK (lock mass)
13
C12-HxCDF
HxCDD
13

C12-HxCDD

OCDPE

Mass

Nominal dwell
time (sec)

303.902
305.899
315.942
317.939
319.897
321.894
331.937
333.934
373.840
380.976

0.090
0.090
0.090
0.090
0.090
0.090
0.090
0.090
0.090
0.090

303.902
305.899
319.897
321.894
337.863
339.860
349.903
351.900
353.858
355.855
365.898
367.895
380.976
407.801

0.045
0.045
0.045
0.045
0.045
0.045
0.045
0.045
0.045
0.045
0.045
0.045
0.035
0.035

373.821
375.818
380.976
385.861
387.859
389.816
391.813
401.856
403.853
443.759

0.080
0.080
0.080
0.080
0.080
0.080
0.080
0.080
0.080
0.080

�Table 6 (continued)

Descriptor
A4

Mass

ID
PFK (lock mass)
HxCDD

380.976
389.816
391.813
407.782
409.779
419.822
421.819
423.777
425.774
435.817
437.814
429.768
431.765
477.720

C12-HpCDF

HpCDD
13
37

C12-HpCDD

Cl4-HpCDD

NCDPE
A5

PFK (lock mass)
OCDF
13

C12-OCDF

OCDD
13

C12-OCDD

DCDPE

15

0.040
0.040
0.040
0.040
0.040
0.040
0.040
0.040
0.040
0.040
0.040
0.040
0.040
0.040

380.976
441.743
443.740
453.784
455.781
457.738
459.735
469.779
471.776
511.681

HpCDF
13

Nominal dwell
time (sec)

0.060
0.070
0.070
0.070
0.070
0.070
0.070
0.070
0.070
0.060

�Table 7. Typical Daily Sequence for PCDD/PCDF Analysis

1. Tune and calibrate mass scale versus perf1uorokerosene (PFK).
2. Determine column performance by injecting the TCDD isomer mixture.
3. Inject concentration calibration solution 2.5 to 12.5 pg/|A (CS-7)
solution.
4. Inject blank (tridecane).
5. Inject samples 1 through "n".
6

Inject concentration calibration solution 2.5 to 12.5 pg/pL (CS-7)
solution.

16

�E.

Data Interpretation

1. Qualitative
The HRGC/MS elution profiles of the tetra- through octachloro PCDD
and PCDF homologs were established through the analysis of environmental sample extract (fly ash from a municipal waste incinerator). The characteristic
ions for each homolog were plotted within the retention window established
using this mixture. The criteria for identification of a response as a PCDD
or PCDF were the coincidental response of the characteristic ions monitored
within the established retention window, and within ± 20% of the theoretical
ion ratio. Table 8 presents the range of ion ratios used for the qualitative
criteria for the specific PCDD and PCDF homologs and internal standards.
2. Quantisation
Quantisation of the specific PCDD and PCDF congeners was achieved
using the respective internal quantisation standards. For example, TCDD was
quantitated versus the 13C12-2,3,7,8-TCDD; PeCDD versus the 13C12-1,2,3,7,8PeCDD, etc. The HpCDF and OCDF responses were quantitated versus the carbon-13
labeled hepta- and octachlorodibenzo-p_-dioxin internal standards since the
corresponding dibenzofuran internal standards were not available for this
study. The absolute recovery of the internal quantisation standards was
achieved using 13C12-1,2,3,4-TCDD. A second internal recovery standard,
37
Cl4-l,2,3,4,6,7,8-HpCDD, was evaluated but was not used for recovery measurements due to interference arising from the corresponding native HpCDD.
Relative response factors (RRF) were calculated for each of the
native PCDD and PCDF compounds listed in Table 2. The RRF values were calculated as shown in Equation 1.
"crn x
STD

RRF = A

R

T&lt;^

1S

X c

IS X LSTD

Eq. 1

where Arjn = the sum of the area responses for the two characteristic ions
of the standard compound;
AT&lt;- = the sum of the area responses for the two characteristic ions
of the corresponding internal quantisation standard;
CIS = concentration (pg/|jL) of the internal quantisation standard; and
= concentration (pg/uL) of the standard compound.
The relative response factors for the internal quantisation standards (RRFjS) were calculated as shown in Eq. 2.

17

�Table 8.
Compound
TCDF
13
C12-TCDF
TCDD
13
C12-TCDD
PCDF
13
C12-PeCDF
PeCDD
13
C12-PeCDD
HxCDF
13
C12-HxCDF
HxCDD
13
C12-HxCDD
HpCDF
13
C12-HpCDF
HpCDD
13
C12-HpCDD
OCDF
13
C12-OCDF
OCDD
13
C12-OCDD

Ion Ratios for HRGC/MS Analysis of PCDD/PCDF

Ions monitored

Theoretical ratio

304/306
316/318
320/322
332/334
338/340
350/352
354/356
366/368
374/376
386/388
390/392
402/404
408/410
420/422
424/426
436/438
442/444
454/456
458/460
470/472

0.76
0.76
0.76
0.76
0.61
0.61
0.61
0.61
1.22
1.22
1.22
1.22
1.02
1.02
1.02
1.02
0.87
0.87
0.87
0.87

Acceptable range is ± 20% of the theoretical value.

18

Acceptabl e range'

0.61 - 0.91
0.61 - 0.91
0.61 - 0.91
0.61 0.49 0.49 0.49 0.49 0.98 0.98 0.98 0.98 0.82 0.82 0.82 0.82 0.70 0.70 0.70 0.70 -

0.91
0.73
0.73
0.73
0.73
1.46
1.46
1.46
1.46
1.22
1.22
1.22
1.22
1.04
1.04
1.04
1.04

�TC *
RRF

IS
IS

=

QG.
Eq

AH RS x CLjg
X

"2

where A JS and GIS are defined as in Equation 1 and
C10 = concentration (pg/uL) of the internal recovery standard,
DC
13
C12-1,2,3,4-TCDD, and
A RS = the sum of the area responses for the two characteristic ions
(m/z 332 and 334) corresponding to the internal recovery
standard.
A calibration curve was established using six concentration levels
of standards; for example, the calibration curve for 2,3,7,8-TCDD was initially established with standards at concentrations of 1, 2.5, 5, 10, 50, and
100 pg/(jL. The 2.5 pg/uL standard was analyzed daily to verify response
factors and instrument sensitivity. The RRF values for each of the internal
quantisation standards were calculated versus the internal recovery standard,
13
C12-1,2,3,4-TCDD, using Equation 2.
The concentration of a PCDD or PCDF congener in a composite sample
was calculated as shown in Equation 3.
_ Asamp1e x QIS
Vr AIS x RRF x Wt
r

where

P

tq&gt;

~
*

CUT = wet tissue concentration of the PCDD or PCDF congener in each
tissue (pg/g);
A sample = sum of the area responses for the two characteristic ions of
,
thfi pC[JD Qr pCDF congener;

A-,&lt;- = sum of the area responses for the two characteristic ions of
the respective internal quantitation standard;
Q T r = amount of the internal quantitation standard added to the
1:&gt;
13
sample (500 pg of 13C12-TCDD,13 C12-TCDF, 13C12-PeCDD,
13
and 13C12-PeCDF; 1,250 pg of C12-HxCDD, 13C12-HxCDF,
and C12-HpCDD; or 2,500 pg of 1§C12-OCDD);
RRF = the relative response factor for the PCDD or PCDF congener
from Equation 1; and
Wt = mass of the sample (grams).
The absolute recovery of the internal quantitation standard was
calculated using Equation 4.

19

�L
Recovery (%) = •?
*
^
ARS x RRF IS x QIS

where

x 100

Eq 4

AR&lt;- = sum of the area responses for the two characteristic ions of
the internal recovery standard, 13C12-1,2,3,4-TCDD;
QR&lt;- = amount of the internal recovery standard (13C12-1,2,3,4-TCDD)
added to the final extract (500 pg); and
RRF IS = response factor of the internal quantisation standard relative
to the internal recovery standard. These values are calculated as defined in Equation 2. The RRF T&lt; - values were all
calculated versus 13C12-1,2,3,4-TCDD.

All data were qualified to reflect that the response for a particular compound was a positive quantifiable parameter, present as a trace value
only, or was not detected. Positive quantifiable values were identified for
responses greater than 10 times background signal to noise. Trace (TR) values
were assigned to responses which were in the range of 2.5 to 10 times background signal to noise. A value of not detected (ND) was used to reflect that
a response was not detected at greater than 2.5 times signal to noise. A limit
of detection (LOD) was calculated for all trace and not detected values using
the peak height response of the respective internal standard and the average
measured signal to noise for the characteristic ions of the PCDDs and PCDFs.
F.

Quality Assurance/Quality Control (QA/QC)

The QA/QC procedures included analysis of multipoint calibration
concentration standards to establish relative response factor (RRF) curves
for each of the 17 native PCDD and PCDF congeners. Triplicate analyses of
6 concentration calculation standards (Table 2; CS2, CSS, CSS, CS6, CS7, and
CSS) were determined to vary by less than ± 20% for TCDD and TCDF and ± 30%
for all other PCDD and PCDF congeners. The mean RRF values were also determined to vary by less than this criteria over the entire calibration range.
The mean RRF (RRF) values and instrument sensitivity were verified daily by
bracketing the sample analyses with an injection of a standard that ranged
from 2.5 pg/uL for 2,3,7,8-TCDD and 2,3,7,8-TCDF up to 12.5 pg/(jL for OCDD
and OCDF. The criterion for continuing with the sample analysis was agreement of the measured RRF value with the mean RRF within ± 20% for 2,3,7,8TCDD and TCDF and ± 30% for all other PCDD and PCDF congeners.
Other activities included the analysis of laboratory method blanks
and reagent blanks and measurement of the absolute recoveries of the internal
quantisation standards. Laboratory method blanks were samples that were handled exactly as an adipose sample except no lipid matrix was used.
G.

Preliminary Method Studies

Prior to analysis of the homogenized human adipose lipid matrix by
HRGC/MS, several experiments were conducted to confirm that the sample preparation scheme was feasible.

20

�1. Gravimetric Studies
The first concern was the efficient removal of up to 10 g of lipid
matrix from extracted adipose tissue. A series of experiments was conducted
with 10-g lipid aliquots to demonstrate removal of lipid using the H2S04-Si02
slurry technique. Initially, 50 g of the acid modified silica was added to
the lipid extract in 100 ml of hexane. The acid modified silica was noted to
turn dark brown immediately on contact with the lipid solution. The hexane
was recovered and the adsorbent was extracted with additional hexane. The
extracts were combined and concentrated to 5 mL with Kuderna-Danish evaporators.
The extract was eluted through a column of 4.0 g of acid modified silica and
1.0 g of silica with 45 ml of hexane. The acid modified silica was noted to
be highly discolored throughout, and the extract required a second slurry
treatment of the eluent with an additional 50 g of acid modified silica gel.
The adsorbent from the second slurry procedure was noted to discolor significantly, indicating that lipid materials had not been efficiently removed from
the first step of the procedure. The hexane supernatant from the second
slurry cleanup was reduced in volume and taken to dryness in a preweighed
glass vial. The final residue was measured at approximately 10 mg for duplicate samples, which translates into a removal efficiency of 99.9% based on
the initial 10-g aliquot.
This lipid cleanup procedure was modified such that 100 g of acid
modified silica gel was used in the initial slurry cleanup, followed by elution of the resulting extract through a column containing 4.0 g of acid modified silica and 1.0 g of silica gel. The lipid removal efficiency of duplicate samples through the cleanup procedure was determined to average 99.8%
(20 to 30 mg of the initial 10-g lipid remained after cleanup). The column
cleanup step in this procedure did not exhibit any significant color change.
Thus this step of the procedure was incorporated into the method as a check
of the efficiency of lipid removal to prevent overloading of the acidic alumina fractionation column.
2. Carbon-14 Recovery Studies
The carbon-14 radio!abeled PCDD standards listed in Table 1 were
used to estimate overall method recoveries for the tetra- through octachloro
homologs prior to proceeding with the HRGC/MS evaluation. Triplicate analyses
(10-g aliquots of lipid materials) were conducted with each of the three
radiolabeled standards. The first experiment addressed the recovery of the
compounds from bulk lipid cleanup. Triplicate analyses using 10-g aliquots
were completed for the three compounds at the following concentrations:
14
C-2,3,7,8-TCDD, 10 pg/g; 14C-l,2,3,4,7,8-HxCDD, 100 pg/g; and 14C-OCDD,
250 pg/g. The results of these analyses indicated that all compounds were
recovered in the range of approximately 70 to 80%. Following this experiment,
the total sample preparation procedure described earlier in this report was
evaluated using triplicate analysis of 10-g lipid samples. Table 9 provides
a summary of the results from this study. These data indicate that overall
method recovery is limited by the initial bulk lipid removal procedure. This
assumption is based on the similar recoveries of the carbon-14 labeled compounds noted for evaluation of the bulk lipid removal step as compared to the
total sample preparation scheme.

21

�Table 9. Summary of the Results of the Sample Preparation
Method Evaluation Using Carbon-14 PCDDs
Spike
levels

Bulk lipid
removal,
recovery

Analytes

(pg/g)

Total method a
recovery ( )
%

14

C-2,3,7,8-TCDD

10

68

75

14

100

79

66

250

82

76

C-l,2,3,4,7,8-HxCDD

14

C-OCDD

Average value for triplicate analyses taken through the total sample
preparation scheme. Precision of measurements varied by less than ± 10%
(relative standard deviation).
Average value for triplicate analyses taken through bulk lipid cleanup
only. Precision of measurement varied by less than ± 6% (relative standard deviation).

22

�V.

RESULTS

A. Analytical Results
The analytical results for the quantisation of the 17 target PCDD
and PCDF 2,3,7,8-substituted congeners in the spiked and unspiked homogenized
human adipose lipid samples are presented in Tables 10 to 15. These data
demonstrate that 13 of the 17 congeners were definitely detected in the unspiked lipid matrix. Although 2,3,7,8-TCDF is reported as not detected, responses for the characteristic ions (m/z 304 and 306) greater than 10 times
signal to noise were noted to be coincident with the internal standard, 13C122,3,7,8-TCDF. The ratio of the responses (m/z 304/306) in each of the triplicate analyses of the unspiked matrix were well outside the acceptable ratio
of 0.90 to 0.61 established in Table 8. Figure 1 provides a comparison of
the HRGC/MS-SIM responses noted for the unpsiked human adipose lipid matrix
as compared to a concentration calibration standard. Figures 2 through 6
provide examples of the individual PCDD and PCDF responses observed for the
unspiked lipid samples as compared to fortified matrices.
In general, the precision of the replicate measurements at each
spike level is good (relative standard deviations typically less than 10%)
for PCDD and PCDF congeners that were detected with responses greater than 10
times signal to noise. The precision of the measurements for the unspiked
matrices for 1,2,3,7,8-PeCDF (Table 11), 1,2,3,7,8,9-HxCDF (Table 12), and
OCDF (Table 15) ranges from 21.6% to 43.1% as a result of little or no response at the specified retention windows.
B. Statistical Analysis
The regression results for each of the 17 specific PCDD and PCDF
congeners are plotted separately in Figures 7 to 23. These plots provide the
results for the individual sample analyses, a line defining the results of a
least squares regression analysis, and boundaries that depict the confidence
limits for the range of spiked concentrations. The regression lines were obtained by the method of least squares using the sample measurements at the
three spiking levels and the unspiked level.
Two types of upper and lower 95% confidence limits or bounds were
calculated for the least square regressions of measured (found) concentrations
versus spiked levels. The first set of confidence limits (defined by the
inner pair of curves closest to the regression line) is the 95% confidence
bounds for the regression line. These bounds are interpreted as follows:
The true regression line (as would be determined if the experiment were repeated a countless number of times at the same spiked levels) lies within
these confidence limits unless the analytical results are sufficiently unusual
to be among those expected to occur less than 5% of the time.
The second set of confidence bounds, depicted by the outer pair of
lines, constitutes the 95% confidence limits for the result of a single analysis at a particular spiking level. The interpretation is as follows: the
result (reported value) of a single analysis of a sample spiked at a given
level can be predicted to fall between these 95% confidence bounds unless the
analytical result is among those sufficiently unusual to be expected less than
5% of the time.
23

�Table 10. Spiked Versus Measured Concentrations of 2,3,7,8-TCDF and 2,3,7,8-TCDD
in Homogenized Human Adipose Lipid Samples
13

13

C12-TCDF
absolute
recovery ( )
%

2,3,7,8-TCDD
spike level

(pg/g)

(pg/g)

C12-TCDD
absolute
recovery (%)

(.)
41*
( . )a
41?
(.)
40
(.)
41
0.1
1.8

59
63
59
60.3
2.3
3.8

0
0
0

10.7
11.4
13.1
11.7
1.2
10.5

53
52
46
50.3
3.8
7.5

10
10
10
10

14.3
14.8
13.6
13.8
14.1
0.5
3.9

61
67
71
78
69.3
7.1
10.3

10
10
10
10

23.4
22.8
24.7
22.5
23.3
1.0
4.1

53
53
53
62
55.3
4.5
8.1

25
25
25
25

30.8
30.8
30.7
28.7
30.2
1.1
3.5

59
75
62
72
67.0
7.7
11.5

25
25
25
25

40.8
40.6
40.3
38.3
40.0
1.2
2.9

48
53
51
60
53.0
5.1
9.6

50
50
50

57.7
59.4
55.8
57.6
1.8
3.1

64
48
58
56.7
8.1
14.3

50
50
50

65.8
72.1
67.6
68.5
3.3
4.8

55
43
48
48.7
6.0
12.4

2,3,7,8-TCDF
spike level

2,3,7,8-TCDF
concentration

(pg/g)
0
0
0
Mean
STD
RSD (%)

ro

Mean
STD
RSD ( )
%

Mean
STD
RSD (%)

Mean
STD
RSD (%)

(pg/g)
ND
ND
ND
ND

2,3,7,8-TCDD
concentration

ND = not detected. Value in parentheses is the estimated limit of detection. A response of greater than
10 times signal-to-noise was noted for both characteristic ions (m/z 304 and 306) at the appropriate
retention time for 2,3,7,8-TCDF. However, the ion ratio was considerably greater than the acceptable
range of 0.61 to 0.90.

�i au ic J.A.
Table 11.

1,2,3.7,8-PeCDF
spike level

(pg/g)
0
0
0

STO
RSD ( )
%
10
10
10

10

Mean
STO
RSD ( )
%

25
25
25

Mean
STD
RSD ( )
%

a

ND (l.l)
ND ( . )
08
ND ( . )
08

12.2
11.5
11.9
11.4

29.2
30.1
28.5
25.5

50

51.3
55.9
55.5
54.2
2.5
4.7

C12-PeCDF
absolute

2,3,4,7,8-PeCDF
concentration

(pg/g)

(pg/g)

0
0
0

20.8
21.6
19.0

75
76
80

20.5
1.3
6.5
10
10
10
10

27.6

recovery (%)

1,2,3,7,8-PeCDD
concentration

(pg/g)

(pg/g)

0
0
0

20.2
19.9
18.1

51
54
57

19.4
1.1
5.7

54.0
3.0
5.6

32.1
37.6
30.8
30.4

60
57
55
62

30.2
1.9
6.3

58.5
3.1
5.3

48.0

43.5

55
60
57
64

46.7

59.0

2.5
5.4

3.9
6.6

3.4

.

32.4
4.9
15.2

50
50
50

54.9

48.5
41.7
48.2

62
81
87
84

78.5
11.3
14.4

74.6
62.9
71.9

64

69.8

69.3
5.0
7.3

10
10
10
10

78.0
11.7
15.1

48.4
5.4
11.1

25
25
25
25

36.3

90
63
84
75

37.0
28.7

6.1
8.8

NO = not detected. The value in parentheses is the estimated limit of detection.

74
70

13

1,2,3,7,8-PeCDO
spike level

77.0
2.6

28.3
2.0
7.0
50
50

Mean
STD
RSD (%)

(pg/g)

13

2,3,4,7,8-PeCDF
spike level

11.8
0.4
3.1
25

CJl

1,2,3,7,8-PeCDF
concentration

,t
versus neasureij uunueniT at IUMS ui .L ,£ , j , / ,o rex-ur f &amp;(j , / ,o rev,Lrr „ anu x ,£. , i ,o rc^uu
t j,
iii Homogenized Human Adipose Tissue Sampl es

ND (0.9)
0.2
21.6

Mean

ro

j\j 1 1«;u

25
25
25
25

50
50
50

46.1
49.3

C12-PeCDO
absolute
recovery (%)

72.2
72.8

58
54
56

71.6

56.0

69.7

1.6
2.3

2.0
3.6

�Table 12.
in Homogenize(1 Human Adipose L ipid Matrix
1,2,3,4,7,8HxCDF

spike level
(P9/Q)

0
0
0
Mean
STD
RSD ( )
%

Mean
STD
RSD (X)

Mean
STD
RSD ( )
%
125
125
125

1,2,3,6,7,8HxCOF
concentration

2,3,4,6,7,8HxCDF
spike level

2,3.4,6.7.8HxCDF
concentration

1,2,3,7,8,9HxCDF
spike level

1,2,3,7,8,9HxCDF
concentration

13

C12-HxCDF

(pg/g)

(pg/g)

(pg/g)

(pg/g)

(pg/g)

(pg/g)

(pg/g)

absolute
recovery
()
%

22.0
22.1
22.4

0

12.3
12.4
12.7

0
0
0

4.9
4.2
4.2

0

NO (0.5)a
NO ( . )
07
NO ( . )
09

55
57
52

ND ( . )
07
0.2
25.3

55.7
2.5
4.6

concentration

0
0

46.7
52.0
48.8
49.0

25
25
25
25

90.2
89.1
90.3
90.7

156.3
0.9
0.6

25
25
25
25

62.5
62.5
62.5
62.5

83.7
80.5
79.6
76.0

62.5
62.5
62.5
62.5

3.2
3.9
151.0

157.7
149.1

32.3
33.6
32.0
32.5

25
25
25
25

74.7
75.5
74.2
71.1

125
125
125

152.6

4.5

2.9

ND = not detected. The value in parentheses reflects the estimated limit of detection.

141.9
141.6
151.0
144.9
5.3
3.7

34.8
28.5
30.9
29.2
30.9
2.8
• 9.1

59
57
60
67

60.8
4.3
7.2

125
125
125

82.7
89.4
82.2
76.3

60
63
63
70

82.7
5.4
6.5

62.5
62.5
62.5
62.5

73.9
2.0
2.6

79.9

125
125
125

0

32.6
0.7
2.1

39.0
1.8
4.7

90.1
0.7
0.7

157.2
155.4
156.4

36.6
38.6
40.8
39.8

0

4.4
0.4
8.9

12.4
0.2
1.7

49.1
2.2
4.4
62.5
62.5
62.5
62.5

Mean
STD
RSD (X)

1,2,3,6,7,8HxCDF
spike level

22.2
0.2
1.1
25
25
25
25

no
en

1,2,3,4,7,8HxCDF

64.0
4.2
6.6

143.0
144.1
163.4

57
54
57

150.1
11.4
7.6

56.0

1.7
3.1

�Table 13.

in Homogenized Human Adipose Lipid Samples

1

1,2,3,4,7,8-HxCDD
concentration

1,2,3,7,8,9-HxCDD

1,2,3,7,8,9-HxCDD

concentration

spike level

concentration

(pg/g)

1,2,3,6,7,8-HxCDD
spike level

1,2,3,6,7,8-HxCDO

spike level

(pg/g)

(pg/g)

(pg/g)

(pg/g)

(pg/g)

0

21.6
22.7
20.3

0
0
0

157.0
162.0
154.0

0
0
0

19.1
26.0

2,3,4,7,8-HxCDD

0
0

Mean
STD
RSD ( )
%
25
25
25
25

Mean
STD
RSD ( )
%

62.5

Mean
STD
RSD ( )
%

82.9
96.7
90.3
81.9

141.1
150.8
146.0
145.9
4.9
3.3

184.0
165.0
198.0
193.0

62.5
62.5
62.5
62.5

220.0
239.0
220.0
220.0

288.0
299.0
266.0
284.3
16.8
5.9

63.5
46.1
40.8
57.3

65
61
65
70

51.9
10.4
20.0

65.3
3.7
5.6

3.7

25
25
25
25

125
125
125

114.0
99.9
101.2
107.4

64
66
66
77

105.6
6.5
6.1

62.5
62.5
62.5
62.5

224.8
9.5
4.2
125
125
125

58
60
58

58.7
1.2
2.0

23.2

185.0
14.5
7.9

87.9
7.0
7.9
125
125
125

Mean
STD
RSD ( )
*

25
25
25
25

51.6
2.6
5.1
62.5
62.5
62.5

ro
--J

47.8
52.0
53.7
52.7

C12-HxCDD
absolute
recovery (%)

15.8

157.7
4.0
2.6

21.5
1.2
5.5

24.7

13

68.3
5.9
8.7

141.3
152.7
189.4

62
57
61

161.1
.25.2
15.6

60.0
2.6
4.4

�Table 14. Spiked Versus Measured Concentrations of 1,2,3,4,6,7,8-HpCDF, 1,2,3,4,7,8,9-HpCDF, and 1,2,3,4,6,7,8-HpCDD
in Homogenized Human Adipose Lipid Samples

1 ?,3,4,6,7,8-HpCDF

1,2,3,4,6,7,8-HpCDF

1,2,3,4,7,8,9-HpCDF

spike level

concentration

(pg/g)
0
0
0

Mean
RSO ( )
%
25
25
25
25

Mean
STD
RSD ( )
%

ro
00

(pg/g)

(pg/g)

(pg/g)

(pg/g)

(pg/g)

30.6
27.3
28.6

0
0
0

NO (1.3)*
NO ( . )a
11*
NO ( . )
10

0
0
0

214.7
210.8
215.5

71
74
69

213.7
2.5
1.2

71.3
2.5
3.5

214.7
239.0
243.9
248.5

83
75
76
78

243.3
4.0
1.7

78.0
3.6
4.6

281.5
288.1
269.9
274.9

77
84
90
99

278.6
8.0
2.9

87.5
9.3
10.7

353.2
355.4
343.7

62
61
69

350.8
6.2
1.8

64
4.4
6.8

48.6
48.6
51.0
56.3

ND ( . )
11"
0.2
13
25
25
25
25

Mean
STD
RSD ( )
*

86.3
85.7
80.9
83.4

62.5
62.5
62.5
62.5

84.1
2.5
2.9
125
125
125

154.5
157.3
154.4
155.4
1.6
1.0

ND - not detected.

26
23
23
25

25
25
25
25

24.1
1.4
5.7

51.1
3.6
7.0
62.5
62.5
62.5
62.5

C12-HpCDD
absolute
recovery ( )
%

spike level

1,2,3,4,6,7,8-HpCDD
spike level

28.9
1.6
5.7

STO

l3

1,2.3,4,7,8,9-HpCDF
concentration

60
60
59
58

62.5
62.5
62.5
62.5

59.0
0.8
1.3
125
125
125

119
126
121

122.4
3.7
3.0

The value in parentheses is the estimated limit of detection.

125
125
125

1,2,3.4,6,7,8-HpCDD
concentration

�Table 15. Spiked Versus Measured Concentrations of OCDF and OCDD
in Homogenized Human Adipose Lipid Samples
13

OCDF
spike level

OCDF
concentration

spike level

OCDD
concentration

(pg/g)

(pg/g)

(pg/g)

(pg/g)

0
0
0

4.9

0
0
0

804
833
781

88
94

806.1
26.1
3.2

91.0
3.0
3.3

Mean
STD
RSD (%)
50
50
50
50

Mean
STD
RSD (%)
125
125
125
125

Mean
STD
RSD ( )
%
250
250
250

Mean
STD
RSD ( )
%

2.3
2.6

OCDD

3.2
1.4
43.1

44.2
45.0
45.9
49.6

50
50
50
50

849
856
876
860

860.4
11.4

46.2
2.4
5.2

111.1
107.8
110.7
113.1

1.3

125
125
125
125

()
%
91

100
87
91
91

92.3
5.5
6.0

932
934
944

90
96
102

907

110.7
2.2
2.0
227.8
231.0
228.6

C12-OCDD
abolute recovery

104

929.1
15.7
1.7

250
250

98.0
6.3
6.5

1,080
1,140
1,070
1,096
34.7
3.2

250

229.1
1.7
0.7

29

69
67
74

70.0
3.6
5.2

�Umpiked Human Adipose Tiisue

13 C ,

i,2.:

TCDF
,3.7.B-Kf&gt;F
,?.3.4-?CDO
icon
.3.7.IMCDU
B-fcCDr

13C|

?,3.&lt;

8-PfCDf
8-N-CDD

'Vl'

. 1,2.:

tt. t.2,3

,3.6,7,B-M.COD
9-Hi-COlJ
9'lliiCDf
7.B-HpCDF
7,i-HpCt&gt;n
,3,«.4.7,ft-hpCDD
.7.3.4,«,7,B-HpCDD
,7,B,9-HpCDF

75 OCOO
36 '3C17-OCDO
37 OCDf

R1C

21,22.23

16.17

1B19

W^W**&lt;

JlJVWsMM.

izee

Calibrolion Slaiidorcl

1,12

RIC
15,16,17

6,7

21,22.23

9.10

roe

12M

14m

16M

2«M SOW

Figure 1. Comparison of the HRGC/MS-SIM reconstructed ion chromatogram (RIC)
from the analysis of unspiked homogenized human adipose tissue
matrix and a calibration standard for PCDDs and PCDFs.

30

�Umpik.d Human Adipau

384 .

Spiked Human Adipaic
2.3.7,8-TCDF

304 .

9M

nee

958

use

1286

1256

SCAN

Umpiktd Humon Adipou

328 .

r !3 C|2-lCDF

^2.3,7,8-ICDO

A. A.
iee.e-i
Spiked Humon Adipoie

32« .

&gt;3C|2-2.3.7,8-TCDFi

9flO

tew

-2.3.7,8-TCDD

urn

1280

1230

SCAN

Figure 2. Example of the TCDF (m/z 304) and TCDD (m/z 320) HRGC/MS-SIM
elution profiles in unspiked and spiked human adipose. The spiked
concentrations for TCDF and TCDD in these chromatograms were 25 pg/g
each.

31

�Urapik.d Human Adlpow
2.3.4.7.B-P.CDF

338 .

1.2.3,7.8-P.CDF

\
Spiked Human Adipnia
2.3.4,7,8-P.CDF
1.2,3,7,8-P.CDF-,

338 .

nee

use

12*9

izse

I3*e

t3se

1400

SCMN

Unspiktd Human Adipose

3C|2-I.2.3.7,8-P.CDF

354 .

(1.2,3,7.88-P.CDD

.. A

.

Spik«d Human AdipoM

354 .

.2.3.7.8-P.COD

1308

13M

I4W

SCAN

Figure 3. Example of the PeCDF (m/z 338) and PeCDD (m/z 354) HRGC/MS-SIM
elution profiles in unspiked and spiked human adipose. The spiked concentrations for each isomer of PeCDF and PeCDD in these chromatograms
were 25 pg/g.

32

�Umpiked Human Adipose

|l.2,3,&lt;.7.8-HxCDf

h,2.3.6.7.8-HxCDF

374 .

2.3.4.6,7,8-HxCDF

Spiked Human Adipote

l.2,3.&lt;.7,8-HxCLIF | | l.2.3.6.7.8-HxCDF
r2,3,4,6.7.6-.
\H»CDF
374 .
1.2,3.7,8.9-HxCDF

1343

1238

1366

1363

1358

1558

U_B9

1468

MSB

1588

1558

1668

SMI

Umpiked Human Adipole

1.2,3.6.7.B-HxCDD

1,2.3,4.7.8-llxCDD-

339 .

'3C)2-l,2.3,4,7,8-hxCDF
A 1,2.3.7.8,9-Hx
Spiked Human Adi

,2.3,6.7.fl-HxCDD

3M .

1.2.3,4,7.8-HxCDD

\

1.2,3,7.6.9-HxCDD

l3C|2-l,2.3,&lt;.7,8-HxCDFl

1398

1356

1488

1450

1588

1558

16!«

1E58

SOW

Figure 4. Example of the HxCDF (m/z 374) and HxCDD (m/z 390) HRGC/MS-SIM
elution profiles in unspiked and spiked human adipose. The spiked concentrations for each isomer of HxCDF and HxCDD were 62.5 pg/g.

33

�Umpik.d Human AdlpoM
,2,3.4.6,7,8-HpCDF

468 .

Splk.d Human Adipotl
l,2.3.4.6.7.8-HpCDF

488 .

Jl.2.3.4.7.8,9-HpCDF

MM

ISM

1556

1CM

I65B

1768

[750

18M

SCAN

Umpikcd Human Adipau
1,2.3.4.6,7,8-HpCDD
424 .

Spik.d Human Adipoit

1.2,3,4.6.7,8-MpCDO
424 .

1588

1558

1688

1638

17W

1758

1868

1858

SCtH

Figure 5. Example of the HpCDF (m/z 408) and HpCDD (m/z 424) HRGC/MS-SIM
elution profiles in unspiked and spiked human adipose. The spiked concentrations for each isomer of HpCDF and HpCDD were 62.5 pg/g.

34

�ll3c,2-OCDD

Unipik.d Human Adipotc

442 .

Spik.d Hunan Adipau

13

C|2-OCDD|

AJ
17W

1758

ieee

ISM

1658

1358

2988

SCAM

Untpikad Human Adipose

OCDD

458 .

Spik.d Human Adipow

OCOD

458 .

1968

2MB SCAN

Figure 6. Examples of the OCDF (m/z 442) and OCDD (m/z 458) HRGC/MS-SIM
elution profiles in unspiked and spiked human adipose. The spiked concentrations for OCDD and OCDF were 125 pg/g each.

35

�80

70 -

Regression Line-

t»
tt

a
vx
d
o

•H
+&gt;

60 J

95% Confidence Limifs
for Regression Line

50 -J

td

0

CO

a
ti
o
u

30 -

95% Confidence Limifs
for Individual Analyses

10

0

I

20

10

D

30

i
40

Spiked Concentration (pg/g)
lipid sample meas.

Figure 7. Measured concentrations versus concentrations of 2,3,7,8-TCDD
spiked into the homogenized human adipose lipid matrix.

50

�80

70 -

Regression Line-

ue
(4

95% Confidence Limits
for Regression Line

60 -

o

•H

50 -

d
4)
0

GO
-vl

d
0
u
•d
d

4:0 -

30 -

•95% Confidence Limits
for Individual Analyses

10

i
10

r
20

D
Figure 8.

r
30

i
40

Spiked Concentration (pg/g)
lipid sample meas.

Measured concentrations versus concentrations of 1,2,3,7,8-PeCDD
spiked into the homogenized human adipose lipid matrix.

50

�160
150 Regression Line-

140 130 C4

a

95% Confidence Limits
for Regression Line

130 110 -

o

•H

100 90 -

d

80 -

fl
0

70 -

0
0

CO
CO

u

60 -

•a
d

50 95% Confidence Limits
for Individual Analyses

40
30
20
10
0

I
40

I
20

D
Figure 9.

T
60

T

80

100

Spiked Concentration (pg/g)
lipid sample meas.

Measured concentrations versus concentrations of 1,2,3,4,7,8-HxCDD
spiked into the homogenized human adipose lipid matrix.

120

�a

v_/

o

*H

55

u
ti

CO

o
u
•d
fl

330
310 300 390 380 370 360 350 340 330
330 310 300 190 180 170
160
150
140 H
130

Regression Line.

95% Confidence Limitsfor Regression Line

95% Confidence Limits
for Individual Analyses

I

40

30

D

i
60

80

100

Spiked Concentration (pg/g)
lipid sample meas.

Figure 10. Measured concentrations versus concentrations of 1,2,3,6,7,8-HxCDD
spiked into the homogenized human adipose lipid matrix.

130

�(4
M

a
0

•H
4&gt;

ti
u

0
0

d

0

u
•0
C

200
190 180 170 160 150 140 130 120 110 100 90 80 H
70

60
50
40
30
20
10
0
-10

Regression Line
95% Confidence Limitsfor Regression Line

-i
-

•95% Confidence Limits
for Individual Analyses

i
40

l
20

D
Figure 11.

i
60

i
80

100

Spiked Concentration (pg/g)
lipid sample meas.

Measured concentrations versus concentrations of 1,2,3,7,8,9-HxCDD
spiked into the homogenized human adipose lipid matrix.

120

�Lfr

Fovmd.

(Q

c
n&gt;

T3 (t)
_.. 0)
7T- (/&gt;

ro c

a. -?
n&gt;
- . Q.
1
3
r^ n
o o
r*- o
3- n&gt;
fD 3
c*
3" -5
o a&gt;
3 r+

0 -"•
CQ o
fD 3

3 tn
N &lt;
fD fD
O. -i
(ft
3" C

c in
01 n
3 o
3
o&gt; n
a. n&gt;
O -5

v&gt; Q&gt;

fD r+

_j.
—' O
-&gt;• 3
•O V&gt;

Q. O
-h
Q) I-1

-5 ro

00

•o
o
a
a

a
Ul

•a
I—i M«

•-" te*
us
SP-

Sg
3

S
•Eg
a&gt; 5*i

BR
o jr-

ft O
M 9

•o
9Q
m

Concentration

�1.15
Regression Line-

1.1

M
ft

95% Confidence Limitsfor Regression Line

1.05
1

0 n

•H _l
41

ti H
C

0.95

g 0

0.9

U~

0.85 -|

(4 ti

~

•a
3

•95% Confidence Limits
for Individual Analyses

0.8

0

0.75 0.7

I

40

80

D

120

160

200

Spiked Concentration (pg/g)
lipid sample meas.

Figure 13. Measured concentrations versus concentrations of OCDD spiked
into the homogenized human adipose lipid matrix.

T

340

�60

Regression Line-

50 bl

95% Confidence Limitsfor Regression Line

a
d
o

40 -

30 ti
0

GO

a
d
o
u

•0
d

•95% Confidence Limits
for Individual Analyses

10 -

0

I
10

I
20

n
Figure 14.

30

40

Spiked Concentration (pg/g)
lipid sample meas.

Measured concentrations versus concentrations of 2,3,7,8-TCDF
spiked into the homogenized human adipose lipid matrix.

50

�60

Regression Line'

50 H

95% Confidence Limitsfor Regression Line

M

a

40 -^

c

0

30 fl

0
0

C

20 -

0

u
•d

a

95% Confidence Limits
for Individual Analyses

10 -

-10

D

Spiked Concentration (pg/g)
lipid sample meas.

Figure 15. Measured concentrations versus concentrations of 1,2,3,7,8-PeCDF
spiked into the homogenized human adipose lipid matrix.

�90

Regression Line-

80 -

tfl

d
o
d

95% Confidence Limitsfor Regression Line

70 -

60

50 -

0
0

cn

d
u
0

30 •95% Confidence Limits
for Individual Analyses

10

I

I

i

10

20

30

D
Figure 16.

i
40

Spiked Concentration (pg/g)
lipid sample meas.

Measured concentrations versus concentrations of 2,3,4,7,8-PeCDF
spiked into the homogenized human adipose lipid matrix.

50

�160
150 140 M

Regression Line-

130 95% Confidence Limitsfor Regression Line

ti
o

110 100 90 -

ti
0)

o
ti
0

u
•d
fl

80 70 60 -

•95% Confidence Limits
for Individual Analyses

50 40 30 30
10

i
40

T
20

D
Figure 17.

i
60

T

80

100

Spiked Concentration (pg/g)
lipid sample meas.

Measured concentrations versus concentrations of 1,2,3,4,7,8-HxCDF
spiked into the homogenized human adipose lipid matrix.

120

�160
150 -^
140 M

130 -

(4

130 -

a
0

•H
+&gt;
(fl

u

Regression Line

95% Confidence Limitsfor Regression Line

110 100 90 80 -

0

70 -

0

60 -

ti
u
•d
ti

50 •95% Confidence Limits
for Individual Analyses

40 30 30 10 J

0
0

I
30

I

40

D
Figure 18.

i
60

r
80

100

Spiked Concentration (pg/g)
lipid sample meas.

Measured concentrations versus concentrations of 1,2,3,6,7,8-HxCDF
spiked into the homogenized human adipose lipid matrix.

130

�/-s
tt

d
o

0
0
CO

ti

0

u
•d

a

160
150
140
130
130
110
100
90
80
70
60
50
40
30
20
10
0
-10

-

0

Regression Line-

95% Confidence Limitsfor Regression Line

95% Confidence Limits
for Individual Analyses

20

40
D

60

80

100

Spiked Concentration (pg/g)
lipid sample me as.

Figure 19. Measured concentrations versus concentrations of 2,3,4,6,7,8-HxCDF
spiked into the homogenized human adipose lipid matrix.

120

�170

Regression Line
ttt

95% Confidence Limits
for Regression Line

*
ft

o

•H

0
0

a
0

u
•d
fl

95% Confidence Limits
for Individual Analyses

100
D

Spiked Concentration (pg/g)
lipid sample meas.

Figure 20. Measured concentrations versus concentrations of 1,2,3,7,8,9-HxCDF
spiked into the homogenized human adipose lipid matrix.

120

�130
120 -

110 01

100 -

Regression Line-

90 -

o
•H
4*

95% Confidence Limitsfor Regression Line

80 70 60 -

4)
0

en
O

50 -

o

0

40 -

TJ
ti

30 -

a

95% Confidence Limits
for Indjvidual Analyses

20
10 H

0

-10
0

i
40

I
20

D

i
60

i
80

100

Spiked Concentration (pg/g)
lipid sample meas.

Figure 21. Measured concentrations versus concentrations of 1,2,3,4,7,8,9-HpCDF
spiked into the homogenized human adipose lipid matrix.

120

�Found

Concentration.

�240
220 200 U

Regression Line &gt;

180 -

95% Confidence Limitsfor Regression Line

160 -

ti
o

140 120 -

d

100 -i

fi
0

80 -

0
0

en
ro

u
•d
ti

•95% Confidence Limits
for Individual Analyses

60 40 20 -

-20

r
80

I
40

0

D
Figure 23.

120

160

200

Spiked Concentration (pg/g)
lipid sample meas.

Measured concentrations versus concentrations of OCDF spiked
into the homogenized human adipose lipid matrix.

240

�The slopes of the calculated regression lines from the data points
in each of the 14 analyses can be used as an indication of the accuracy of
the analytical method for the 17 target analytes. Figure 24 is a plot of the
slope of regression lines versus the 17 individual compounds. Table 16 provides a key to specific compounds associated with a number on the x-axis of
this plot. The plot presents the estimated slope from each least squares regression line as well as the upper and lower 95% confidence limits for the
slope. The slope of the regression line can be interpreted as a measure of
accuracy with a value of 1.00 equivalent to 100% agreement of the measured
concentration with the theoretical values (background plus spike level). The
plot of the 95% confidence limits presents some confirmation on the precision
of measurements across the four spike levels. These confidence bounds can
also be used to determine whether the accuracy of the measurements (slope of
regression line) is significantly different from 100% (or 1.00). If the vertical line connecting the lower and upper 95% confidence limits intersects
with the horizontal line at 1, then the accuracy of the method (as determined
from the regression line) is not significantly different from 100% (slope =
1.00). The results plotted in Figure 24 demonstrate that the method accuracies for 7 of the 17 analytes are not significantly different from 100%.
On the other hand, if the upper and lower confidence limits are both
greater than or both less than 1.00, then the accuracy of the method is significantly different from 100%. The data presented graphically in Figure 24
indicate that some positive bias (greater than 100%) is associated with the
method accuracies for 9 of the 17 analytes while the measurements for a single
analyte (OCDF) result in a slightly negative (less than 100%) bias.
Table 16 provides a key to the compound identification in Figure 24
and tabulates the slope of the regression lines and the upper and lower 95%
confidence limits for each of the 2,3,7,8-substituted PCDD and PCDF analytes.
As noted from Table 16, method accuracy (as defined by the regression line
slope) ranges from 90% for OCDF up to 121% for 1,2,3,7,8,9-HxCDF. The accuracies for all other measurements fall within a range of 97 to 115%. The
overall method accuracies meet the initial accuracy objective of 50-115%
identified in the project quality assurance program plan. However, the predicted accuracy results for individual analysis as defined by the 95% upper
confidence limits indicate that this range should be adjusted to 50-130%.
The bias in the accuracy of the measurements may be a result of
slight differences in the concentration calibration standards and the internal
quantisation standard and native PCDD and PCDF spiking solutions. As a preliminary check on these differences, solutions of the low level and of the
high level native spike combined with the internal quantitation standards were
analyzed. The results of these analyses are provided in Table 17. Accuracy
was calculated as measured/spiked x 100.
The results of these analyses suggest that bias observed in overall
method accuracy is attributed to the differences in the spiking solutions versus the calibration standards. For instance, the four HxCDF isomers demonstrated a consistent positive bias to method accuracy based on the least squares
regression analysis. The analysis of the spiking solutions, submitted as samples, also indicates a definite positive bias for the same four HxCDF isomers.

53

�ACCURACY

ESTIMATES

1.3 -

1.2 n
M

£
o&gt;
«

II

-I-

1.1 -

§•

II

:TT

+

0.9 -

0.8

4(014(024(034(044(054(064(0741084(094110#11 4(124(134&gt;144(154(1 64(17
D slope estimate

Compound Number
4
lower 95* CL

o

upper 953C CL

Figure 24. Method accuracy estimates as determined from the slopes of
the least squares regression lines for the 17 target PCDD and
PCDF analytes. Refer to Table 16 for the key to compound number.

54

�Table 16. Regression Line Slopes with 95% Confidence Limits
Significantly Lower 95%
different
confidence

Compound

no.

Compound

Upper 95%
confidence

Slope

from 1.00?

limit

limit

1.08
1.13
1.07
0.98

yes
yes
yes
no

1.04
1.08
1.02
0.82

1.11
1.19
1.12
1.13

01
02
03
04

2,3,7,8-TCDF
2,3,7,8-TCDD
1,2,3,7,8-PeCDF
2,3,4,7,8-PeCDF

05

1,2,3,7,8-PeCDD

1.04

no

0.98

1.11

06
07
08
09
10

1,2,3,4,7,8-HxCDF
1,2,3,6,7,8-HxCDF
2,3,4,6,7,8-HxCDF
1,2,3,7,8,9-HxCDF
1,2,3,4,7,8-HxCDD

1.07
1.12
1.12
1.21
0.98

yes
yes
yes
yes
no

1.06
1.09
1.09
1.12
0.92

1.09
1.16
1.15
1.29
1.05

11

1,2,3,6,7,8-HxCDD

1.01

no

0.86

1.16

12
13
14
15
16
17

1,2,3,7,8,8-HxCDD
1,2,3,4,6,7,8-HpCDF
1,2,3,4,7,8,9-HpCDF
1,2,3,4,6,7,8-HpCDD
OCDF
OCDD

1.12
1.01
0.97
1.08
0.90
1.15

no
no
no
yes
yes
yes

0.94
0.95
0.95
1.01
0.88
1.00

1.30
1.07
1.00
1.16
0.92
1.30

55

�Table 17.

Compound

Results of the Analysis of the Low and High Level Native Spike Solutions
Low level spike
Measured
Spike
concentration concentration
(pg/uL)
(pg/uL)

High level spike
Accuracy

Spike
concentration
(pg/uL)

Measured
concentration
(pg/uL)

Accuracy
108
114

2,3,7,8-TCDF
2,3,7,8-TCDD

13
12

130
120

50
50

54

1,2,3,7,8-PeCDF
2,3,4,7,8-PeCDF

10
10
10

11
10
12

110

1,2,3,7,8-PeCDD

en

10
10

100
120

50
50
50

52
49
53

1,2,3,4,7,8-HxCDF
1,2,3,6,7,8-HxCDF
2,3,4,6,7,8-HxCDF
1,2,3,7,8,9-HxCDF
1,2,3,4,7,8-HxCDD
1,2,3,6,7,8-HxCDD
1,2,3,7,8,9-HxCDD

25
25
25
25
25
25
25

27
32
35
40
27
24

125
125
125
125
125
125

134
137
152

39

108
128
140
160
108
96
156

125

123
132
148

1,2,3,4,6,7,8-HpCDF
1,2,3,4,7,8,9-HpCDF
1,2,3,4,6,7,8-HpCDD

25
25

25

22
25
26

88
100
104

125
125
125

116
121
130

97
104

OCDF
OCDD

50
50

44
48

88
96

250
250

247
250

99
100

57

185

104
98
106
107
110
122
148
98

106
118
93

�Similar trends are noted for other compounds in Table 17 compared to the data
presented in Figure 24 and Table 16.
The limited number of analyses of the spiking solutions does not
provide an adequate comparison with the sample data to confirm the bias.
However, it is recommended that at least triplicate measurements of the spiking solutions at each fortification level should be analyzed at the outset of
the actual NHATS sample analysis program. This will be necessary to account
for any biases that will be observed from the determination of PCDD and PCDF
residue levels in spiked QC samples. It should be noted that additional
homogenized spiked samples will be prepared prior to initiation of the NHATS
sample analyses.
1. Recovery of Internal Quantitation Standards
The absolute recoveries for the carbon-13 labeled internal quantitation standards were determined for each sample by comparing the responses
to the internal recovery standard, 13C12"1,2,3,4-TCDD. The average recoveries
of the compounds13in Tables 10 to 15 range from 52.1% for 13C12-2,3,7,8-TCDD
up to 88.9% for C12-OCDD. The results for the absolute recoveries compared to the overall method accuracy for each compound indicate the importance
of the internal standard quantisation technique for analysis of the PCDDs and
PCDFs in human adipose.
2. Estimation of Background Levels of PCDDs and PCDFs
The estimated background levels of the various PCDD and PCDF congeners were determined as the intercept obtained from the least squares linear
regression analyses. Table 18 provides a comparison of the average measured
values for the unspiked matrix and the background concentration estimates from
linear regression analysis of the data. In general, the measured and estimated background levels are in good agreement. However, several analytes with
concentrations of less than 5 pg/g, particularly OCDF, demonstrate some disagreement in the measured versus estimated concentrations. This apparently
arises from the fact that the first spike level is significantly greater than
the actual background concentration. In the case of OCDF, the first spike
level estimated by linear regression was 50 pg/g compared to an average measured value of 3.2 pg/g. In order to provide a better estimate of the background level based on the linear regression analysis, additional spike levels
between 5 and 50 pg/g would be required. Table 18 also provides the upper
and lower 95% confidence limits for the background levels estimated by the
linear regression analysis of the data. These estimated background levels
and confidence limits can be viewed as the intersections of the regression
line and its upper and lower 95% confidence bounds, respectively, with the
y-axis (measured or found concentration). These values will be used as the
initial data points for developing control charts of the unspiked lipid matrix which will be analyzed with each batch of samples throughout the EPA/VA
study.

57

�Table 18. Background Level Estimates with 95% Confidence Limits

Compound
no.

01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17

Measured
background
level

(pg/g)a

Compound
2,3,7,8-TCDF
2,3,7,8-TCDD
1,2,3,7,8-PeCDF
2,3,4,7,8-PeCDF
1,2,3,7,8-PeCDD
1,2,3,4,7,8-HxCDF
1,2,3,6,7,8-HxCDF
2,3,4,6,7,8-HxCDF
1,2,3,7,8,9-HxCDF
1,2, 3,4,7, 8-HxCDD
1,2,3,6,7,8-HxCDD
1,2,3,7,8,9-HxCDD
1,2,3,4,6,7,8HpCDF
1,2,3,4,7,8,9HpCDF
1,2,3,4,6,7,8HpCDD
OCDF
OCDD

ND ( . )
41C
11.5
ND (0.9)
20.5
19.4
22.2
12.4
4.4
ND (0.7)
21.5
157.75
23.2
28.9

Estimated
background
level

(pg/g)

Level
significantly
different
from zero?

Lower 95%
confidence
limit

Upper 95%
confidence
limit

(pg/g)

(pg/g)
4.5
13.3
2.5
26.4
21.5
23.5
13.7
6.5
8.2
29.3
169.5
38.7
29.6

(3.6)
11.8
ND (1.1)
22.2
19.8
22.4
11.2
4.3
ND (2.3)
24.9
159.4
26.5
25.7

yes
yes
no
yes
yes
yes
•j
yes
•J

yes

2.7
10.4
-0.2
17.9
18.2
21.3
8.6
2.1
-3.6
20.5
149.3
14.3
21.9

ND (0.3)

no

-2.1

1.5

213.7

214.0

yes

208.9

219.1

3.2
806.1

ND (1.0)
799.7

no
yes

-1.7
779.4

3.8
820.0

ND

(1.1)

ND

yes
*j
no
yes
•j
yes

yes

.The measured background levels are the averages of the triplicate analyses of the unspiked matrix.
The estimated background levels were derived from the linear regression analysis of data.
ND = not detected. The value in parentheses reflects the estimated method
detection limit.

�3. Day-to-Day HRGC/MS Analysis Precision
In addition to the analysis of the replicate spiked samples, four
extracts were analyzed by HRGC/MS on two different dates. The results of the
duplicate HRGC/MS analyses of these four samples for the 17 target compounds
are presented in Tables 19 to 21. Concentration values from the second analysis date were included in the statistical analysis of data presented earlier
in this section.

59

�Table 19. Day-to-Day Precision of Analysis of Specific Sample Extracts
for Tetra- and Pentachloro PCDF and PCDD
Analysis
date
4/22/86
4/28/86

Spike
level

(pg/g) (pg/g)
0
0

RPD ( )
%b

4/22/86
4/28/86

0
0

RPD ( )
%

ND (3.1)
ND (4.1)
28

0
0

ND (3.3)
ND (4.0)

1,2,3,7,8PeCDF

2,3,7,8TCDD

2,3,4,7,8PeCDF

1,2,3,7,8PeCDD

(pg/g)

(pg/g)

(pg/g)

(pg/g)

10

ND ( . 4
08)
ND (1.12)

24
21

18
20

13

11

23
22

17
20

4

16

16
19

17
18

11
10

29

ND (0.78)
ND (0.75)

10

11

4

10

ND (0.81)
ND (0.75)

10
13

19

RPD (%)

4/22/86
4/28/86

ND ( . )
30a
ND (4.1)
29

RPD ( )
%

4/22/86
4/28/86

2,3,7,8TCDF

10
10

26

8

17

6

12
14

21
23

11
12

26
28

27
19

18

9

8

7

35

.ND = not detected. Value in parentheses is the estimated limit of detection.
Relative percent difference. Calculated as the difference of the two values
divided by the mean of the two values times 100%.

60

�Table 20. Day-to-Day Precision of Analysis of Specific Sample Extracts for Hexa- and Heptachloro PCDF and PCDD

Analysi s
date
4/22/86
4/28/86

Spike
level

1,2,3,
4,7,8HxCDF

1,2,3,
6,7,8HxCDF

2,3,4,
6,7,8HxCDF

1,2,3,
7,8,9HxCDF

1,2,3,
6,7,8HxCDD

1,2,3,
7,8,9HxCDD

1,2,3,4,
6,7,8HpCDF

1,2,3,4,
7,8,9HpCDF

1,2,3,4,
6,7,8HpCDD

(pg/g)

1,2,3,
4,7,8HxCDD

(pg/g)

(pg/g)

(pg/g)

(pg/g)

(pg/g)

(pg/g)

(pg/g)

(pg/g)

(pg/g)

(pg/g)

0
0

21
22

12
12

5

0

22
22

12
12

0

0

20
23

12
13

14

8

10

44
47

36
37

6

3

RPD ( )
%b

4/22/86
4/28/86

0
0

RPD ( )
%

4/22/86
4/28/86

0
0

RPD ( )
%

4.2
4.9

ND (0.33)a
ND (0.51)

ND (0.83)
ND (0.36)

210
216

20
22

149
170

16
19

28
31

10

13

17

10

21
23

150
178

18
26

25
27

17

36

8

21
20

176
171

18
25

27
29

71

5

3

33

7

116

3

28
32

30
35

43
49

171
181

46
63

46
49

23
25

235
241

13

15

13

6

31

6

8

3

15

4.0
4.2

5
3.9
4.3

43

ND (0.32)
ND (0.74)
79

ND (0.41)
ND (0.86)

9 '

79

ND ( . 9
10)
ND (1.14)
4

ND (1.06)
ND (0.28)

3
207
211

2
223
216

CTl

4/22/86
4/28/86
RPD ( )
%

a

25
25

.
Relative percent difference. Calculated as the difference of the two values divided by the mean of the two values times 100%.

�Table 21. Day-to-Day Precision of Analysis of Specific Sample Extracts
for OCDF and OCDD
Analysis
date

OCDF
concentration

OCDD
concentration

(pg/g)

(pg/g)

(pg/g)

0
0

4.9
3.5

811
810

Spike
level

4/22/86
4/28/86
RPD ( )
%a

33
2.2
2.3

0
0

4/22/86
4/28/86

4

RPD ( )
%

1.9
2.6

0
0

4/22/86
4/28/86
RPD ( )
%

2
788
784

1

43
44

834
848

2

50
50

RPD ( )
%

.

819
836

31

4/22/86
4/28/86

a

0.1

2

.

values divided by the mean of the two values times 100%.

62

�VI.

QUALITY ASSURANCE/QUALITY CONTROL (QA/QC)

As discussed in the experimental section of this report, the QA/QC
activities included the analysis of a multipoint calibration curve, daily
verification of relative response factors for each analyte, analysis of a
method blank and reagent blanks along with the samples, and determining the
absolute recoveries of each of the internal quantitation standards for every
sample. Each of these QA/QC activities is discussed below.
A.

Initial Calibration

At the outset of sample analysis activity, six calibration concentration standards containing each of the target PCDDs and PCDFs at varying
levels and constant concentrations of the internal quantitation and recovery
standards were analyzed in triplicate. The relative response factors (RRF)
for each native compound and internal quantitation standard were determined
for each standard analysis. An average RRF and relative percent standard
deviation (RSD) were determined for each concentration level. The average
RRF values from each of the six concentration calibration standards were then
used to calculate a grand mean RRF value for each compound in the calibration
solution. Table 22 presents a summary of the grand mean RRF values for each
component in the standards. As noted from Table 22, the average RRF values
for native PCDDs and PCDFs generally varied by less than ± 10% (RSD) with the
exception of the pentachloro congeners. These results fall well within the
criteria established in the draft quality assurance program plan which required the variability of RRF values for the tetrachloro homologs to be within
± 20% (RSD) while the RRF criterion on all other compounds was set at ± 30%
(RDS).
The variability of the RRF values for the internal quantitation
standards, on the other hand, was noted to increase with the degree of chlorination. This is a result of the measurement of all internal quantitation
standards versus the single internal recovery standard, 13C12-1,2,3,4-TCDD.
A second internal recovery standard, 37Cl4-l,2,3,4,6,7,8-HpCDD, was evaluated.
However, problems resulting from contribution of native HpCDD to the characteristic ions of this internal standard resulted in variabilities in the RRF
value up to 50%. Hence, this internal standard was not used for any calculations. It is anticipated that an additional internal recovery standard, such
as 13C12-l,2,3,4,7,8-HxCDD, will reduce the variability in the RRF values of
the higher chlorinated internal quantitation standards. This compound will
be incorporated into the method if available.
The sensitivity of the Kratos MS-50TC to the tetra- through octachloro PCDDs and PCDFs was demonstrated through the triplicate analysis of
the low level standard (CS-8, Table 2) that ranged in concentration from
1 pg/pL for the tetra- and pentachloro congeners up to 5 pg/pL for the octachloro congeners. These solution concentration values of 1 pg/pL and 5 pg/uL
correspond to residue levels in tissue of 1 pg/g and 5 pg/g, respectively.
Table 22 provides an indication of the observed signal-to-noise ratio for
each of the native PCDD and PCDF congeners. These data demonstrate that the
low level standard is well above the instrument detection limit, which is defined as the amount of a particular compound necessary to give a signal 2.5
times the background signal to noise for each of the characteristic ions while
meeting the qualitative criteria for ion ratios.

63

�Table 22. Relative Response Factors (Grand Means) Determined from
Multipoint Concentration Calibration Standards

Compound

Wa
1.00
0.80
0.98
1.
.06
1.
,33
0.94
0.93
0.86
0.86
1.
,31
1.
,44
1.
,61
2. 33
1.
.89
,19
1.
1.
,38
1.04

RRF
controj
RSD (%) limits

2,3,7,8'-TCDD
1,2,3,7 ,8-PeCDF
2,3,4,7 ,8-PeCDF
1,2,3,7 ,8-PeCDD
1,2,3,4 ,7,8-HxCDF
1,2,3,6 ,7,8-HxCDF
2,3,4,6 ,7,8-HxCDF
1,2,3,7 ,8,9-HxCDF
1,2,3,4 ,7,8-HxCDD
1,2,3,6 ,7,8-HxCDD
1,2,3,7 ,8,9-HxCDD
1,2,3,4 ,6,7,8-HpCDF
1,2,3,4 ,7,8,9-HpCDF
1,2,3,4 ,6,7,8-HpCDD
OCDF

OCDD
13

C12-l,2,3,4-TCDD

ia

C12-2,3,7,8-TCDD

ia

Ci2-l,2,3,7,8-PeCDD

ia
Ci2-l,2,3,6,7,8-HxCDD
ia
C12-l,2,3,4,6,7,8-

HpCDD
*C14-1,2,3,4,6,7,8-

3

5.7
6.2
5.2
10.1
11.3
3.1
2.4
2.7
6.9
4.9
3.0
1.0
4.0
3.6
4.7
3.3
2.5

0.80-1.20
0.64-0.96
0.68-1.28
0.74-1.38
0.93-1.73
0.66-1.22
0.65-1.21
0.60-1.12
0.60-1.12
0.92-1.70
1.01-1.87
1.13-2.09
1.63-3.03
1.32-2.46
0.83-1.55
0.97-1.79
0.73-1.35

0.70
1.28
0.41
0.33

7.6
4.7
4.5
7.7
15.8
19.6
25.8

1.58-2.38
1.38-2.08
0.95-1.77
0.49-0.91
0.90-1.66
0.29-0.53
0.23-0.43

0.12

51.8

0.24

2,3,7,8'-TCDF

28.0

00
98
73
36

Signal-to-noise
ratio for low
level standard
12
6.5
11
8.9
5.7
32
30
29
17
13
14
14
35
26
13
31
21

Calibration
range
(pg/uL)
1-100
1-100
1-100
1-100
1-100
2.5-250
2.5-250
2.5-250
2.5-250
2.5-250
2.5-250
2.5-250

2.5-250
2.5-250
2.5-250
5-500
5-500
50

50
50

50
50
125
125
125
125

0.17-0.31

250

= grand mean RRF.
RRF control limits designate the acceptable range of values based on the criteria for
± 20% of the KRF for 2,3,7,8-TCDD and 2,3,7,8-TCDF and ± 30% of the REP~for all other
PCDD and PCDF compounds.
Value for signal-to-noise ratio based on observed response for the major
characteristic ion for each native PCDD or PCDF congener (Data File
,8501017X02).
Internal recovery standard.

64

�B. Daily Verification of Response Factors
Before proceeding with analysis of samples, the analyst was required
to verify the existing response factor calibration through the analysis of a
calibration standard (CS-7, Table 2). Criteria for proceeding with sample
analysis required that the measured RRF value for 2,3,7,8-TCDD and 2,3,7,8-TCDF
were within ± 20% (and all other congeners within ± 30%) of the mean RRF established from the calibration curve. This standard was also analyzed at the
end of each working day to demonstrate that the calibration had been maintained.
All RRF values were tabulated to generate RRF control charts for each specific
PCDD and PCDF congener.
Figures 25 through 34 are plots (control charts) of the RRF values
established for the 17 individual target analytes. The RRF data are plotted
versus time of analysis. These plots contain 28 individual data points, 18
of which were generated for triplicate analysis of 6 concentration calibration
solutions from initial calibration and 10 analyses of solution CS-7 (Table 2)
injected over the 5 days for which actual samples were analyzed. The upper
and lower boundaries (dashed lines) represent a relative standard deviation
of approximately ± 10% with the exception of the plot for 1,2,3,7,8-PeCDD,
for which the boundaries are plotted as ± 20%.
It should be noted that the actual control limits as specified in
the project QAPP were set at ± 20% for 2,3,7,8-TCDD and 2,3,7,8-TCDF and ± 30%
for all other target analytes. Boundaries of ± 10% have been used in Figures
25 through 34 as a means to provide the reader with a better perspective in
the actual distribution of the measured calibration points. The values for
the acceptable ranges of each PCDD and PCDF compound based on the initial calibration are presented in Table 22. The data presented for the RRF values in
Figures 25 through 34 are well within these established control limits. The
average RRF values and corresponding standard deviations reported in each of
these plots are calculated from the total 28 standard analyses.
C. Blanks
As specified in the quality assurance program plan, a laboratory
method blank was prepared along with the 14 human adipose lipid samples. The
method blank was taken through all procedures as if it were an actual sample,
although no lipid matrix was introduced. The analysis of the method blank
resulted in the data reported for each of the target analytes reported in
Table 23. As noted in Table 23, 1,2,3,4,6,7,8-HpCDD and OCDD were detected
at concentrations equivalent to 4.0 and 30 pg/g (equivalent to a 10-g lipid
sample), respectively.
The contribution of these PCDDs were not subtracted from the observed
responses for the spiked and unspiked samples. These background levels accounted for less than 2% of the 1,2,3,4,6,7,8-HpCDD and less than 4% of the OCDD
measured in the unspiked lipid samples. In addition to these compounds,
responses that correspond to the elution of two TCDD isomers (1,3,6,8- and
1,3,7,9-) and a PeCDD (isomer not determined) were detected in the method
blank.

65

�e.33?)

(AREA/REF. AREA&gt;/(AKT. /UEF.ANT. &gt;

1.296
1T.CEU.i ST.DEU.6.331
X
MOT

I
?
*

-x,

8.9W

X

DATE

4/23/8S

4/13/85

V

0.897)
ST.DPJ.»

e.ew

7. ST.DEV.=
6.832

8.999

X

Yx
|l

-T

&gt;

»

X

8.788
DATE

4/13/85

4/23/86

3/ 3/8S

Figure 25. Control charts showing response factors by date for 2,3,7,8-TCDF
and 2,3,7,8-TCDD. Dotted lines represent approximately ± 10% of the mean.
66

�Kfflfttift
9.971)

&lt;f*Efl/REF.ftKEA&gt;/&lt;AMT./REF.AMT.&gt; (Ml
1.299

ST.OEU.»
9.083
7. ST.DEU.«
8.739

X
1

i ?
I
i

1.199

IK
fl*
II

L1
1

— "tf.
&gt;f

"

1.899

-JfC

S «
it

¥^

$

i^

'^

S *
1

0.999

1

!

V
^

Sjf
^

- TX

%
X

0.S00

DATE

4/13/86

4/23/86

5/ 3/86

CMF!2,3&lt;4,7,8-FEI(TACHLORO-FyRrtN
.?EFiC13-l,2,3,7,&lt;)-PENTScHLORO-FlJKftH
(flFEfl/REF.IWEft)/ ftMT./REF.AHT.) (flUl
1.499

1.963)
ST.DEU.=
3.113
7. ST.OEU.
18.601

X

1.309

X

— *•*

V

,

1 4
i «
i)
*
N| 1

X

0.309

&gt;—

tt

x

—

"

* X
ii &gt;L)
" *
M M

1.998

?

S4-

X
M . " , *
x ^ ix

v

•

!

'
^

__

X

0.809

X

il.Tm

DATE

4/13/86

4/23/85

3/ 3/86

Figure 26. Control charts showing response factors by date for 1,2,3,7,8-PeCDF
and 2,3,4,7,8-PeCDF. Dotted lines represent approximately ± 10% of the mean.
67

�«K£A/FEF.«Efl&gt;/&lt;«HT./REF.flHT.&gt;
3.800
-

1.375)
ST.OEU."
8.233
7. ST.DEU.18.895

2.899

!x
X
MTE

4/13/86

4/23/86

3/ 3/85

Figure 27. Control chart showing response factors by date for 1,2,3,7,8-PeCDD.
Dotted lines represent approximately ± 20% of the mean.

68

�Cffii 1,2.3,4,7,8-HEXACHLQRO-FUIMN
SEFlC13-l,2..3,4,7,8-HEX«CHLORO-FURftH
(AfiEA/REF.AREAVCAMT./REF.AMT.) &lt;flUi
MM

8.323)
ST.DEU.«
9.816
!! ST.DEI'.'
4.899

.ew

V

V

•xMTE

1
5/ 3/86

4/23/86

4/13^6

!l,2,3,6,7,8-HEXft
1013-1,2,3,4,778-1
&lt;AREfl/REF.I»Efl)/&lt;ftMT./l?EF.flMT.

B.923)

nee

ST.OEU.=
8.048
X ST.DEU."
4.348

-¥•
i.ese

X
i

O
m

K

*

r

0.303

* x

x

3.383
DATE

4/13/86

4/23/86

1
S/ 3/86

Figure 28. Control charts showing response factors by date for 1,2,3,4,7,8-HxCDF
and 1,2,3,6,7,8-HxCDF. Dotted lines represent approximately ± IQ% of the mean.

69

�12,3,4,6,7,8
8.862)

i.ew
ST.DEU.0.838
7. ST. DP.'.
4.429
—

—

,Jfr

Y

8.309

X
1
i
V

*
'

X
V

»•
*•

i
'

Th

T 1
"

xf |
x

0.880

'Y

'

"
A

'

X

x
x x

8.788
DflTE

4/13/86

4/23/86

&lt;flRE«/REF.&lt;*B»/&lt;ftMT./REF.«MT.&gt; &lt;(Wl
1.200
-|

V 3/86

8.883)
ST.OEV.9.882
Z ST.DEV.'
X

1.180

9 327

'

¥

x
^
&gt;f
H

8.900

x ?
'I

1*
|5*
ft
fi
!
i

0.388

ii
x

I

'

u

'

'

'
x

X
T
X

j ^ *
•"

X
A. 7m

DATE

4/13/86

4/23/86

!/ 3/86

Figure 29. Control charts showing response factors by date for 2,3,4,6,7,8-HxCDF
and 1,2,3,7,8,9-HxCDF. Dotted lines represent approximately ± 10% of the mean.
70

�1.394)
1.580

ST.DEU.0.077
7. ST.DEU.=
5.919

V
V

1.4P8

ft
•

X
•^N

'*

Vfl'

-

fJL,

k-

*

i

RX

1

f;
r
II
J1

I
f
^

•SL i

1.399

V

\j/

j^.

/x

!

i !

|

|

i
^
A

I
i
sL
*

*

1

-uw

A

i
!
1.299

1

i

1 !W

DATE

4/13/85

4/23/86

AREA/REF.AREA)/«W./REF.IVIT.) (AUt
1.70B

3/ 3/8S

1.433)
ST.DEU.0.036
Z ST.DEU.»
6.01S

1.609

?
i
I
i

~

'

V

X

«&lt;
III

1.509

iii f
in m
£ *
¥ «i
il

1.400

1.308

(

*
i
x
•

•!* i
•

x

ii
i

/^

1

'

l

i
X

X

I

X

I
.

f

x

&gt;&lt;

X

1 . 7fl«

4/23/86

3/ 3/86

Figure 30. Control charts showing response factors by date for 1,2,3,4,7,8-HxCDD
and 1,2,3,6,7,8-HxCDD. Dotted lines represent approximately ± 10% of the mean.
71

�1.657)
2.300

&gt;

2.200

ST.DEU.=
0.156
7. ST.DEU.
9.384

2.1??
'}

(

2.000

1.909

1.800

X
I
1

X
1.700

V u
1.600

1.590

* »
f 1
;xx

1

;
!x x1 ;

!
* xx

¥

X

1

X
1 400

4/23/86

S/ 3/86

Figure 31. Control chart showing response factors by date for 1,2,3,7,8,9-HxCDD.
Dotted lines represent approximately ± 10% of the mean.

72

�2.228)

&lt;(«BVREF.flREfl)/&lt;ftMT./REF.«MT.)
2.600
•X
*

ST.DEU.0. 132
7. ST.OEU.»
8.163

2.508

X

K X

2.488

in
I
* x
"ft* &amp;
2.309

*
aI
*
i

|i •
i
'
X

t
'

2.288

A

x

i
'

x

X

2.100

X

X

X"1

2.088

X
1.960

X

DrtTE

4/ 3/86

4/23/86

CMFil, 2,3,4, 7,8,3-HEPTflCHLORO-FURfiH
*EFiC13-l, 2,3,4,6 .7,8-HEPTAa*J$J-DIOXIM
i'flREfl/REF.AREfl)/&lt; «1T./R£F.«1T.) (flUl
2. 180
^

1.T83)

X
'
'
7
J

_

*

2.088

5/ 3/86

ST.DEU.'
3. 169
7. ST.OEV.9.420

/jK

i&lt; T
r&gt; i

1.300

m ^11
^

;

-

i
*

1.700

''
X

x

x
—

1.608

—L

r

T

X
1.598

|

X
X

X"

X

^

t.4B«

DATE

4/13/8S

4/23/8S

5/ 3/96

Figure 32. Control charts showing response factors by date for 1,2,3,4,6,7,8-HpCDF
and 1,2,3,4,7,8,9-HpCDF. Dotted lines represent approximately ± 10% of the mean.
73

�(AREA/REF.AREA)/(ANT./REF.MIT.) (AUl
1.486

1.175)
ST.OEU.8.371
7. ST.DEV."
6.043

i.aee

1.2M

*'!
&lt;

!x M
SAC

X

I I

x,

I
X

X .
X

1.100

e.we
DATE

4/13/86

4/23/86

5/ 3/36

Figure 33. Control chart showing response factors by date for 1,2,3,4,6,7,8-HpCDD.
Dotted lines represent approximately ± 10% of the mean.

74

�lOCTflCHLORO-FUf WH
:CI3-OCT«HLOR(M)tOXIH
WT./FEF.flMT.) (flUl

1.238)

1.5W
ST.DEU."
8.117
7. ST.OEU.
8.978

X
1

X

*j
(1

x
U
HI
in
•M

1.40B

I'
*
ji
&gt;i
M

«l

tl

M
M

M
&gt;^f

1.390

ri

1.2W

X

X

/x

-iv -1-

^^

^
&lt;

;
&lt;

i ina

xX
3/8S

4/23/85

;H
IOXIN
&lt;AKEA/REF.ftfiEfl)/&lt;AMT.-/R£F.flt1T.)
1.280

1.033)
ST.DEU.8.943
7. ST.DEU.-

4.181

^ X
1.180

V
X

L-9-ff

1 x
ii
^
i

—i

0.900
DATE

X X

4/13/86

4/23/85

1
3/ 3/86

Figure 34. Control charts showing response factors by date for OCDF and OCDD.
Dotted lines represent approximately ± 10% of the mean.

75

�Table 23. Summary of Results from the Analysis
of a Laboratory Method Blank
Concentration

Compound3

(pg/g)

2,3,7,8-TCDD
2,3,7,8-TCDF
1,2,3,7,8-PeCDF
2,3,4,7,8-PeCDF
1,2,3,7,8-PeCDD
1,2,3,4,7,8-HxCDF

ND
ND
ND
ND
ND
ND
ND
ND
ND
ND

1,2,3,6,7,8-HxCDF
2,3,4,6,7,8-HxCDF
1,2,3,7,8,9-HxCDF
1,2,3,4,7,8-HxCDD
1,2,3,6,7,8-HxCDD
1,2,3,7,8,9-HxCDD
1,2,3,4,6,7,8-HpCDF
1,2,3,4,7,8,9-HpCDF
1,2,3,4,6,7,8-HpCDD
OCDF
OCDD

(0.50)
(2.2)
(0.5)
(0.5)
(1.2)
(0.5)
(0.5)
(0.5)
(0.5)
(1.0)

ND (0.9)
ND (0.8)
ND (0.5)
ND (0.5)
4.0
ND (0.5)
30

a

At least three other PCDD compounds were detected but not quantitated in the laboratory
method blank. These included 1,3,6,8- and
1,3,7,9-TCDD and an unidentified PeCDD

. isomer.
Concentration based on assumption of 10.0 g
equivalent lipid sample. The background
concentration of 1,2,3,4,6,7,8-HpCDD and
OCDD were not subtracted from the measured
concentration for the spiked and unspiked
lipid matrix.

76

�Further analysis of individual reagents used for preparation of
the samples identified the activated acidic alumina as the source of the artifacts. Acidic alumina that had been cleaned by Soxhlet extraction but not
activated at 190°C was analyzed, and the artifacts were not detected. This
indicates that the artifacts are generated during activation of acidic alumina
at elevated temperatures (190°C). Similar background problems from the same
PCDD congeners have recently been reported by the Center for Disease
Control.17'18
An experiment was designed to evaluate a procedure for cleaning the
activated acidic alumina immediately prior to the fractionation of the sample
extract. The acidic alumina (6.0 g) was packed in hexane. The packed column
was eluted with 40 mL of methylene chloride/hexane (1:1) solution followed by
80 to 100 ml of hexane. The sample extract was added to the column and was
eluted with 20 ml of hexane followed by 30 ml of 20% methylene chloride in
hexane which was reserved for PCDD and PCDF analysis.
The carbon-14 radiolabeled 2,3,7,8-TCDD, 1,2,3,4,7,8-HxCDD, and OCDD
were used to evaluate recovery of PCDDs from the cleaned alumina. Recoveries
of the radiolabeled PCDDs from the activated acidic alumina precleaned by the
procedure described above are detailed in Table 24. These data demonstrate
that the selected PCDDs are quantitatively (greater than 90%) recovered from
the precleaned acidic alumina. This procedure for cleanup of activated acidic
alumina was not initiated for the analysis of the lipid samples described in
this report. However, it has been integrated into the analytical protocol
(Appendix A) for routine application with sample preparation activities.
D. Absolute Recoveries of the Internal Quantisation Standards
The absolute recoveries of the carbon-13 labeled internal quantitation standards 13were determined by comparing responses with the internal recovery standard, C12-1,2,3,4-TCDD, which was added during final concentration
prior to HRGC/MS analysis. A summary of the average and range of recoveries
of the 8 internal quantisation standards from the 14 human adipose lipid
samples is provided in Table 25.
These data indicate that recoveries ranged from an average of 52.1%
for 13C12-2,3,7,8-TCDD up to 88.9% for 13C12-OCDD. The average recoveries
for the lower chlorinated internal standards were lower than the preliminary
method studies with carbon-14 radiolabeled standards had indicated. This resulted in a closer evaluation of the final concentration step prior to mass
spectrometry. The first extracts for the human adipose lipid extracts were
concentrated with a nitrogen evaporation system equipped with a water bath at
approximately 55°C. Final blowdown of the samples required addition of the
internal recovery standard in 10 uL of tridecane as a keeper solution. However, it was noted at the elevated temperature final volumes from nitrogen
evaporation were generally on the order of 2 to 5 uL. This required addition
of another 10 uL of tridecane prior to HRGC/MS analysis.
In an effort to assess the effect of reducing the final volume of
tridecane at elevated temperatures on absolute recoveries of the internal
quantisation standards, an experiment using the radiolabeled TCDD, HxCDD, and
OCDD standards was conducted.

77

�Table 24. Recovery of Radio!abeled PCDDs from
Precleaned Activated Alumina
Spike
level
(pg)

Compound

Recovery
(%)

14

100
300
300

92
96
97

14

1,000
3,000
3,000

103
101
100

2,500
7,500
7,500

102
99
97

C-2,3,7,8-TCDD

C-l,2,3,4,7,8-HxCDD

14

C-OCDD

78

�Table 25. Absolute Recoveries of the Internal Quantisation Standards
from the Human Adipose Lipid Matrix

Average
recovery ( )
%

Standard
deviation

Relative
standard
deviation (%)

13

64.0

7.9

12.3

48-78

13

52.1

5.0

9.6

43-62

13

76.1

8.9

11.7

62-90

13

57.1

3.5

6.1

51-64

13

59.4

5.0

8.4

52-70

13

63.6

5.3

8.4

57-77

13

76.3

10.3

13.6

61-99

88.9

11.4

12.9

67-104

Internal
quantitation
standard
C12-2,3,7,8-TCDF

C12-2,3,7,8-TCDD
C12-l,2,3,7,8-PeCDF
C12-l,2,3,7,8-PeCDD

C12-1,2,3,4,7,8HxCDF
C12-1,2,3,6,7,8HxCDD

C12-1,2,3,4,6,7,8HpCDD

13

C12-OCDD

Values based on 14 analyses of human adipose lipid samples.

79

Range of
recovery (%)

�Four solutions of the same spike level were prepared with each
radiolabeled compound in 1 mL of toluene. Two of the spiked solutions were
heated at 55-60°C and the solvent was reduced under a gentle stream of prepurified nitrogen. The toluene solution was concentrated to 100 (jL, 500 pL
of 1% toluene in methylene chloride was added, and the solution was concentrated to 200 uL. At this time 10 uL of the keeper tridecane was added and
the solution was allowed to concentrate further. The remaining two solutions
for each radiolabeled compound were taken through a similar solvent exchange
and concentration procedure except the solution was allowed to concentrate at
room temperature.
One of the most obvious results was the observation that solutions
held at elevated temperatures could be reduced to dryness even when tridecane
had been added as a keeper. On the other hand, solutions for which tridecane
had been added but remained at room temperature could only be concentrated to
a 10-uL final volume. The recoveries of the radiolabeled standards from each
of the solutions in this study are presented in Table 26.
The results from this study indicate that the final concentration
condition may have a pronounced effect on the absolute recoveries of the PCDDs
and PCDFs, especially for the lower chlorinated congeners such as 2,3,7,8-TCDD.
These conclusions are supported by an independent study in comparison of concentration techniques for 2,3,7,8-TCDD.19 However, it should be noted that
the approach to target analyte quantisation based on the internal standard
method (isotope dilution for 8 of the 17 target analytes) is not affected by
absolute recoveries as low as 50%. The procedure for final concentration in
the analytical protocol (Appendix A) for the analysis of the NHATS samples
for the EPA/VA study has been modified to specify room temperature conditions.

80

�and OCDD as a Function of Final Concentration Conditions
Spike
level
Compound

(pg)

Concentration
conditions

Observed
final
volume

Observed
recovery ( )
%

14

300
300
300
300

55-60°C
55-60°C
20°C
20°C

1-2 |jL
dryness
10 uL
10 uL

78
54
98
93

14

3,000
3,000
3,000
3,000

55-60°C
55-60°C
20°C
20°C

1-2 uL
5 uL
10 M L
10 uL

94
102
105
107

7,500
7,500
7,500
7,500

55-60°C
55-60°C
20°C
20°C

1-2 uL
2-3 M L
10 uL
10 |jL

94
94
100
97

C-2,3,7,8-TCDD

C-l,2,3,4,7,8-HxCDD

14

C-OCDD

Each solution was concentrated under a gentle stream of flowing nitrogen.

81

�VII. GLOSSARY OF TERMS
Accuracy - A measurement of the bias of a system, which for this study, is
based on the agreement of the 2,3,7,8 substituted PCDD and PCDF to an accepted reference standard.
Batch, sample - A sample batch consists of up to 10 human adipose tissue samples, one method blank, 2 internal quality control (QC) samples (spiked and
unspiked), and an external performance audit sample (blind spike).
Blank, laboratory method - This blank is prepared in the laboratory through
performing all analytical procedures except addition of a sample aliquot to
the extraction vessel. A minimum of one laboratory method blank will be
analyzed with each batch of samples.
Calibration standards (concentration calibration solutions) - Solutions containing known amounts of the native analytes (unlabeled 2,3,7,8-substituted
PCDDs and PCDFs), the internal quantisation standards (carbon-13 labeled
PCDDs and PCDFs), and the recovery standard, 13C12-1,2,3,4-TCDD. These calibration solutions are used to determine instrument response of the analytes
relative to the internal quantisation standards and of the internal quantitation standards relative to the internal recovery standard.
Lipid - The organic solvent extractable constituents of adipose tissue consisting of fatty oils, proteins, and carbohydrates. The concentrations of
PCDDs and PCDFs are reported on the lipid content bases.
Instrumental mass calibration - An internal instrumental systems check and
tuning standard, perfluorokerosene (PFK), is introduced automatically by the
instrument. The mass ion 380.976 is monitored by the analyst as an instrumental systems check and is also used to tune the instrument.
Internal quantisation standards - Carbon-13 labeled PCDDs and PCDFs, which
are added to every sample and are present at the same concentration in every
method blank and quality control sample. These are added to the adipose
tissue prior to extraction and are used to measure the concentration of each
analyte. The concentration of each internal quantitation standard is measured
in every sample, and percent recovery is determined using the internal recovery
standard.
Internal recovery standard - 13C12-1,2,3,4-TCDD and 13C12-l,2,3,7,8,9-HxCDD
which is added to every sample extract just before the final concentration
step and HRGC/MS-SIM analysis.
Limit of detection (LOD) - A value, derived from the noise to signal response, which is equal to 2.5 times the average instrumental noise level
is the limit of detection.
Limit of quantitation (LOQ) - A value, derived from the noise to signal response, which is equal to 10 times the average instrumental noise level is
the limit of quantitation.

82

�Mass resolution check - Standard method used to demonstrate static resolution
of 10,000 minimum (10% valley definition).
Not detected (ND) - A nonresponse or a response which is less than the limit
of detection is reported as not detected.
Precision - The results from analysis of replicate samples (spiked and unspiked) provide the measure of method precision. The precision of the method
is reported as standard deviation or relative standard deviation.
Performance check mixture, HRGC column - A mixture containing known amounts
of selected TCDD standards; it is used to demonstrate continued acceptable
performance of the capillary column, to separate ( 25 % valley on a 50-m CP
^
Sil 88 or 60-m SP-2330 HRGC column and 30 to 60% for a 60 m DB-5 HRGC column)
2,3,7,8-TCDD isomer from all other 21 TCDD isomers, and to define the TCDD
retention time window.
PCDD - Polychlorinated dibenzo-p_-dioxins.
PCDF - Polychlorinated dibenzofurans.
Relative response factor - Response of the mass spectrometer to a known
amount of an analyte relative to a known amount of an internal standard
(quantitation or recovery).
Trace (TR) - A response which is greater than the limit of detection but less
than the limit of quantitation is reported as a trace value. An estimated
method detection limit is provided for trace value.

83

�VIII.

REFERENCES

1. Stanley JS. 1984. Methods of analysis of polychlorinated dibenzo-£dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) in biological
matrices--!iterature review and recommendations. EPA-560/584-00.
2. Stanley JS, Going JE, Redford DP, Kutz KW, Young AL. 1985. A survey of
analytical methods for measurement of polychlorinated dibenzo-£-dioxins
(PCDD) and polychlorinated dibenzofurans (PCDF) in human adipose tissues.
In: Chlorinated dioxins and dibenzofurans in the total environment II.
Keith LH, Rappe C, Choudhary G, eds. Butterworth Publishers, pp. 181-195.
3.

Stanley JS. 1984 (March 28). Proposed analytical method for analysis
of PCDDs/PCDFs in human adipose tissue: special report. Washington, DC:
Office of Pesticides and Toxic Substances, U.S. Environmental Protection
Agency. Contract 68-02-3938, Work Assignment 8.

4. Stanley JS. 1986 (April 23). Broad scan analysis of human adipose tissue:
polychlorinated dibenzo-£-dioxins (PCDDs) and polychlorinated dibenzofurans
(PCDFs). Draft final report. Washington, DC: Office of Pesticides and
Toxic Substances, U.S. Environmental Protection Agency. Contract 68-023938, Work Assignment 8.
5. Albro et al. 1985. Methods for the quantitative determination of multiple, specific polychlorinated dibenzo-£-dioxin and dibenzofuran isomers
in human adipose tissue in the parts-per-trillion range. An interlaboratory study. Anal Chem 57: 2717-2725.
6. Patterson DG et al. 1986. High-resolution gas chromatographic/highresolution mass spectrometric analysis of human adipose tissue for
2,3,7,8-tetrachlorodibenzo-£-dioxin. Anal Chem 58: 705-713.
7. Schecter A, Tiernan TO, Taylor ML, VanNess GF, Barrett JH, Wage! DJ,
Gitlitz G, Bogdasarian M. 1985. Biological markers after exposure to
polychlorinated dibenzo-p_-dioxins, dibenzofurans, biphenyls, and biphenylenes. Part I: Findings using fat biopsies to estimate exposure.
In: Chlorinated dioxins and dibenzofurans in the total environment II.
Keith LH, Rappe C, Choudhary G, eds. Butterworth Publishers, pp. 215-246.
8.

Schecter A, Ryan JJ. 1985. Dioxin and furan levels in human adipose
tissue from exposed and control populations. 189th National ACS Meeting
Symposium on Chlorinated Dioxins and Dibenzofurans in the Total Environment III, Miami, Florida. Preprint Division of Environmental Chemistry,
ACS 25:160-163, Paper No. 56.

9. Ryan JJ, Williams DT, Lau BPY, Sakuma T. 1985. Analysis of human fat
tissue for 2,3,7,8-tetrachlorodibenzo-£-dioxin and chlorinated dibenzofuran residues. In: Chlorinated dioxins and dibenzofurans in the total
environment II. Keith LH, Rappe C, Choudhary G, eds. Butterworth Publishers, pp. 205-214.

84

�10. Ryan JJ, Schecter A, Lizotte R, Sun W-F, Miller L. 1985. Tissue distribution of dioxins and furans in humans from the general population.
Chemosphere 14: 929-932.
11. Nygren M, Hansson M, Rappe C, Domellof L, Hardel1 L. 1985. Analysis of
polychlorinated dibenzo-p_-dioxins and dibenzofurans in adipose tissue
from soft-tissue sarcoma patients and controls. 189th National ACS
Meeting Symposium on Chlorinated Dioxins and Dibenzofurans in the Total
Environment III, Miami, Florida, 1985. Preprint Division of Environmental Chemistry, ACS 25:160-163, Paper No. 55.
12. Smith LM, Stalling DL, Johnson JJ. 1984. Determination of part per
trillion levels of polychlorinated dibenzofurans and dioxins in environmental samples. Anal Chem 58: 1830-1842.
13. Rappe C, Nygren M, Linstrom G, Hanson H. 1985. Dioxins and dibenzofurans in human tissues and milk of European origin. 5th International
Symposium on Chlorinated Dioxins and Related Compounds, Bayreuth, FRG,
September 16-19, 1985.
14. Ryan JJ. 1985. Variation of dioxins and furans in humans with age and
organ by country. 5th International Symposium on Chlorinated Dioxins
and Related Compounds, Bayreuth, FRG, September 16-19, 1985.
15. Graham M, Hileman FD, Wendling J, Wilson JD. 1985. Chlorocarbons in
adipose tissue samples. 5th International Symposium on Chlorinated
Dioxins and Related Compounds, Bayreuth, FRG, September 16-19, 1985.
16. Patterson DG, Holler JS, Smith SJ, Liddle JA, Sampson EJ, Needham LL.
1985. Human tissue data in certain U.S. populations. 5th International
Symposium on Chlorinated Dioxins and Related Compounds, Bayreuth, FRG,
September 16-19, 1985.
17. Patterson DG, Holler JS, Groce DF, Alexander LR, Lapeza CR, O'Conner RC,
Liddle JA. 1986. Control of interferences in the analysis of human
adipose tissue to 2,3,7,8-tetrachlorodibenzo-£-dioxin (TCDD). Environ
Toxicol Chem 5: 355-360.
18. Holler JS, Patterson DG, Alexander LR, Groce OF, O'Connor RC, Lapeza CR.
1985. Control of artifacts and contamination in the development of a
dioxin analytical program. 33rd Annual Conference on Mass Spectrometry
and Allied Topics, San Diego, CA, May 26-31, 1985.
19. O'Keefe PN, Meyer C, Dillon K. 1982. Comparison of concentration techniques for 2,3,7,8-tetrachlorodibenzo-p_-dioxin. Anal Chem 54: 26232625.

85

�APPENDIX A
ANALYTICAL PROTOCOL FOR DETERMINATION OF PCDDs AND PCDFs
IN HUMAN ADIPOSE TISSUE

A-l

�TABLE OF CONTENTS

Section

Description

Page

1

Scope and Application

A-3

2

Summary of Method

A-3

3

Definitions

A-6

4

Interferences

A-7

5

Safety

A-7

6

Apparatus and Equipment

A-8

7

Reagents and Standard Solutions

A-ll

8

High Resolution Gas Chromatography/Mass Spectrometry

Performance Criteria
9

A-13

Quality Control Procedures

A-31

10

Sample Preservation and Handling

A-33

11

Sample Extraction

A-33

12

Cleanup Procedures

A-35

13

Analytical Procedures

A-38

14

Date Reduction

A-43

15

Reporting and Documentation

A-50

A-2

�ANALYTICAL PROTOCOL FOR DETERMINATION OF PCDDs AND PCDFs
IN HUMAN ADIPOSE TISSUE
1.

SCOPE AND APPLICATION
1.1

1.2

The minimum measurable concentration is estimated to range from
1 pg/g (1 part per trillion) for 2,3,7,8-TCDD and 2,3,7,8-TCDF up
to 5 pg/g for OCDD and OCDF. However, these detection limits
depend on the kinds and concentrations of interfering compounds
in the sample matrix and the absolute method recovery.

1.3

2.

This method provides procedures for the detection and quantitative
measurement of polychlorinated dibenzo-p_-dioxins (PCDD) and polychlorinated dibenzofurans (PCDF) at concentrations ranging from 1
to 100 pg/g for the tetrachloro congeners up to 5 to 500 pg/g for
the octachloro congeners in 10-g aliquots of human adipose tissue.

The method will be used to determine PCDDs and PCDFs, particularly
congeners with chlorine substitution in the 2,3,7,8 positions.
Table 1 lists the specific PCDDs and PCDFs and target method
detection limits.

SUMMARY OF METHOD
Figure 1 presents a schematic of the analytical procedures for determination of PCDDs and PCDFs in human adipose tissue. The analytical
method requires extraction and isolation of lipid materials from human
adipose samples. This is accomplished using sample sizes ranging up to
10 g. The tissue is spiked with known amounts of the carbon-13 labeled
PCDDs and PCDFs (e.g., 500 pg of 13C12-TCDD/F to 2,500 pg of 13C12-OCDD/F)
as internal quantitation standards. Extraction and homogenization are
accomplished using methylene chloride and a Tekmar Tissuemizer®. The
extract is filtered through anhydrous sodium sulfate to remove water.
The extraction procedure is repeated (three to five times) until the
tissue sample has been thoroughly homogenized. The final extract is
adjusted to a known volume (100 ml) and the extractable lipid is
determined using a minimum of 1% of the final volume. The methylene
chloride in the remaining extract is concentrated until only an oily
residue remains. The residue is diluted with hexane ( 200 mL), and
~
100 g of sulfuric acid modified silica gel (40% w/w) is added to the
solution with stirring. The mixture is stirred for approximately 2 h,
and the supernatant is decanted and filtered through anhydrous sodium
sulfate. The adsorbent is washed with at least two additional aliquots
of hexane.
The combined hexane extracts are eluted through a column consisting of a
layer of sulfuric acid modified silica gel, and a layer of unmodified
silica gel. The eluate is concentrated to approximately 1 ml and added
to a column of acidic alumina. The PCDDs and PCDFs are eluted from the
alumina using 20% methylene chloride/hexane. This eluate is concentrated
to approximately 0.5 mL and is added to a 500-mg Carbopak C/Celite column.
The PCDDs and PCDFs are eluted from the column using 20 mL of toluene.
A-3

�Table 1. Target PCDD and PCDF Congeners and Target Method
Detection Limits
Compound
2,3,7,8-TCDD
2,3,7,8-TCDF
1,2,3,7,8-PeCDD
1,2,3,7,8-PeCDF
2,3,4,7,8-PeCDF
1,2,3,4,7,8-HxCDD
1,2,3,6,7,8-HxCDD
1,2,3,7,8,9-HxCDD
1,2,3,4,7,8-HxCDF
1,2,3,6,7,8-HxCDF
1,2,3,7,8,9-HxCDF
2,3,4,6,7,8-HxCDF
1,2,3,4,6,7,8-HpCDD
1,2,3,4,6,7,8-HpCDF
1,2,3,4,7,8,9-HpCDF
OCDD
OCDF

CAS no.3

1746-01-6
51207-31-9
40321-76-4
57117-41-6
57117-31-4
39227-28-6
57653-85-7
19408-74-3
70648-29-9
57117-44-9
72918-21-9
60851-34-5
35822-46-9
67562-39-4
55673-89-7
3268-87-9
39001-02-0

Chemical Abstract Services number.
pg/g = parts per trillion.

3

A-4

Target method detection
limit (pg/g)

1.0
1.0
1.0
1.0
1.0
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
5.0
5.0

�Add Internal Quantitation Standards
Initial Sample Preparation
Isolation of Extractable U'pid Materials

(13c-PCDDs/PCDFs)
Homogenization in Methylene Chloride

I
Lipid Determination
Solvent Exchange

Bulk U'pid Removal
Acid Modified Silica Gel
Slurry Technique

Provides Cleanup of Oxidizable Compounds
with Rapid Sample Turnaround, Improved
Cleanup Efficiency and Recovery

i
Removal of Chemical Interferences
Acidic Silica/Silica
Acidic Alumina

Carbopak C/Celite

Provides Seperation of PCBs and Other
Potential Interferences from PCDDs and PCDFs

Selective Adsorption and Isolation of PCDDs/PCDFs

Add Internal Recovery Standards

HR'GC/MS-SIM Analysis

1

i

LRMS
Identification/Quantitation
of Tetra-Octa PCDDs/PCDFs

HRMS
Confirmation of 2,3,7,8-TCDD

Figure 1. Schematic of the sample preparation and
instrumental analysis procedures for determination
of PCDDs and PCDFs in human adipose tissue.

A-5

�The toluene is concentrated to less than 1 ml and transferred to conical
vials. Tridecane (10 uL) containing 500 pg of an internal recovery standard is added as a keeper, and the extract is concentrated to final volume.
The HRGC/MS analysis is completed in the selected ion monitoring mode
(SIM). Analysis of the tetra- through octachloro PCDD and PCDF congeners
is achieved using low resolution mass spectrometry. Separation of the
tetra- through octachloro PCDD and PCDF congeners is achieved using a
60-m DB-5 column. Verification of the 2,3,7,8-TCDD is achieved using
either a 50-m CP Sil 88 column or 60-m SP-2330 column and HRGC/MS-SIM
analysis in the high resolution mode (R = 10,000).
3.

DEFINITIONS
3.1

Concentration calibration solutions — Solutions containing known
amounts of the native analytes (unlabeled 2,3,7,8-substituted
PCDDs and PCDFs), the internal quantisation standards (Carbon-13
labeled PCDDs and PCDFs), and the recovery standard, 13C121,2,3,4-TCDD. These calibration solutions are used to determine
instrument response of the analytes relative to the internal
quantitation standards and of the internal quantitation standards
relative to the internal recovery standard.

3.2

Internal quantitation standards -- Carbon-13 labeled PCDDs and
PCDFs, which are added to every sample and are present at the
same concentration in every method blank and quality control
sample. These are added to the adipose tissue and are used to
measure the concentration of each analyte. The concentration
of each internal quantitation standard is measured in every
sample, and percent recovery is determined using the internal
recovery standard.

3.3

Internal recovery standard — 13C12-1,2,3,4-TCDD and 13C121,2,3,7,8,9-HxCDD which is added to every sample extract just
before the final concentration step and HRGC/MS-SIM analysis.

3.4

Laboratory method blank — This blank is prepared in the
tory through performing all analytical procedures except
of a sample aliquot to the extraction vessel. A minimum
laboratory method blank will be analyzed with each batch
ples.

3.5

HRGC column performance check mixture -- A mixture containing
known amounts of selected TCDD standards; it is used to demonstrate continued acceptable performance of the capillary column,
to separate (g 25% valley on a 50-m CP Sil 88 or 60-m SP-2330
HRGC column and 30 to 60% for a 60-m DB-5 HRGC column) 2,3,7,8TCDD isomer from all other 21 TCDD isomers, and to define the
TCDD retention time window.

3.6

Relative response factor — Response of the mass spectrometer to
a known amount of an analyte relative to a known amount of an
internal standard (quantitation or recovery).
A-6

laboraaddition
of one
of sam-

�3.7
3.8

4.

Mass resolution check — Standard method used to demonstrate
static resolution of 10,000 minimum (10% valley definition).
Sample batch -- A sample batch consists of up to 10 human adipose
tissue samples, one method blank, 2 internal quality control (QC)
samples (spiked and unspiked), and an external performance audit
sample (blind spike).

INTERFERENCES

Chemicals which elute from the HRGC column with ± 10 scans of the internal and/or recovery standards and which produce within the retention time
window ions at any of the masses used to detect or quantify PCDDs, PCDFs,
or the internal quantitation and recovery standards are potential interferences. Most frequently encountered potential interferences are other
sample components that are extracted along with the PCDDs and PCDFs, e.g.,
PCBs, chlorinated methoxybiphenyls, chlorinated hydroxydiphenyl ethers,
chlorinated benzylphenyl ethers, chlorinated naphthalenes, DDE, DDT, etc.
The actual incidence of interference by these chemicals depends also
upon relative concentrations, mass spectrometric resolution, and chromatographic conditions. Because very low levels (pg/g) of PCDDs and
PCDFs are anticipated, the elimination of interferences is essential.
High purity reagents and solvents must be used and all equipment must be
scrupulously cleaned. Laboratory method blanks must be analyzed to demonstrate absence of contamination that would interfere with measurement of
the PCDDs and PCDFs. Column chromatographic procedures are used to remove
coextracted sample components; these procedures must be performed carefully to minimize loss of PCDDs and PCDFs during attempts to increase
their concentration relative to other sample components.
5.

SAFETY
5.1

The toxicity or carcinogenicity of each reagent used in this
method has not been precisely defined; however, each chemical
compound should be treated as a potential health hazard. The
2,3,7,8-TCDD is a known teratogen, mutagen, and carcinogen. Ingestion of microgram quantities can result in toxic effects. The
other 2,3,7,8-substituted PCDDs and PCDFs may exhibit teratogenic,
mutagenic, and carcinogenic effects. From this viewpoint, exposure to these chemicals must be reduced to the lowest possible
level by whatever means available. Only experienced personnel
will be allowed to work with these chemicals.

5.2

All laboratory personnel will be required to wear laboratory
coats or coveralls, gloves, and safety glasses. The neat standards, stock, and working solutions will be handled only in a
Class A fume hood or glove box. When manipulating stock standards or working solutions, the analyst is advised to place the
solution vials in a secure holder (sample block or glass beaker)
to prevent accidental spills.

A-7

�5.3

5.4

If handling of these compounds results in skin contact, immediately remove all contaminated clothing and wash the affected skin
areas with soap and water for at least 15 min.

5.5

6.

If these standards are spilled, absorb as much as possible with
absorbent paper and place in a container clearly labeled as PCDD
or PCDF waste. Solvent-wash all contaminated surfaces with toluene and absorbent paper followed by washing with a strong soap
and water solution. Dispose of all contaminated materials in
sealed steel containers labeled as contaminated with PCDD and/or
PCDF residue and indicate the approximate level of contamination.
As a final precaution, prepare a wipe sample of the exposed surface area and include the wipe as part of the sample analysis
batch. This will be used to confirm that the work area is free
of contamination.

Disposal of laboratory wastes -- All laboratory wastes (solvents
and absorbents) will be disposed of as hazardous wastes. The
laboratory personnel should take care to dispose of the sodium
sulfate, silica gel, and alumina in separate containers. Excess
solvents should be disposed of in gallon polyethylene jugs containing a layer of activated charcoal. Excess solvent that is
known to be contaminated with PCDDs or PCDFs should be kept at a
minimum by evaporating the solvent with a stream of air.

APPARATUS AND EQUIPMENT
6.1

High Resolution Gas Chromatograph/Mass Spectrometer/Data System
(HRGC/HRMS/DS)
6.1.1

The GC must be equipped for temperature programming,
and all required accessories must be available, such as
syringes, gases, and a capillary column. The GC injection port must be designed for capillary columns. The
use of splitless injection techniques is recommended.
When using this method, a 1-pL injection volume is used.
The injection volumes for all extracts, blanks, calibration solutions, and the performance check sample must
be consistent.

6.1.2

High Resolution Gas Chromatograph-Mass Spectrometer
Interface
The HRGC/MS interface is directly coupled to the mass
spectrometer ion source. All components of the interface should be glass or glass-lined stainless steel.
The interface components should be compatible with
300°C temperatures. The HRGC/MS interface must be
appropriately designed so that the separation of the
PCDDs and PCDFs which is achieved in the gas chromatographic column is not appreciably degraded. Cold spots
and/or active surfaces (adsorption sites) in the HRGC/MS

A-8

�interface can cause peak tailing and peak broadening.
It is recommended that the HRGC column be fitted directly
into the MS ion source. Graphite ferrules should be
avoided in the HRGC injection port since they may absorb PCDDs or PCDFs. Vespel or equivalent ferrules
are recommended.
6.1.3

Mass Spectrometer
The mass spectrometer must be capable of maintaining a
minimum resolution of 10,000 (10% valley) for high resolution confirmation analysis. The mass spectrometer
must be operated in a selected ion monitoring (SIM)
mode with total cycle time (including voltage reset
time) of 1 s or less.

6.1.4

Data System
A dedicated hardware or data system is required to control the rapid multiple ion monitoring process and to
acquire the data. Quantification data (peak areas or
peak heights) and SIM traces (displays of intensities
of each m/z (characteristic ion) being monitored as a
function of time) must be acquired during the analyses.
Quantifications may be reported based upon computergenerated peak areas or upon measured peak heights.

6.2

HRGC Columns
For isomer-specific determinations of 2,3,7,8-TCDD, the following
fused silica capillary columns are recommended: a 50-tn CP-Sil 88
column and a 60-m SP-2330 (SP-2331) column. However, any capillary column which separates 2,3,7,8-TCDD from all other TCDDs may
be used for such analyses, provided that the minimum acceptance
criteria in Section 8 are met.

6.3

Miscellaneous Equipment
6.3.1

Nitrogen evaporation apparatus with variable flow rate.

6.3.2

Balance capable of accurately weighing to ± 0.01 g.

6.3.3

Balance capable of accurately weighint to ± 0.0001 g.

6.3.4

Water bath — equipped with concentric ring cover and
capable of being temperature-controlled.

6.3.5

Stainless steel spatulas or spoons.

6.3.6

Magnetic stirrers and stir bars.

6.3.7

High speed tissue homogenizer -- Tekmar Tissuemizer®
equipped with an EN-8 probe or equivalent.

6.3.8

Vacuum dessicator.

A-9

�6.4

Glassware
6.4.1

Erlenmeyer flask — 500 mL.

6.4.2

Kuderna-Danish apparatus — 500-mL evaporating flask,
15-mL graduated concentrator tubes with ground-glass
stoppers, and three-ball macro Snyder column (Kontes
K-570001-0500, K-503000-0121, and K-569001-0219 or
equivalent).

6.4.3

Minivials -- 1-mL borosilicate glass with conical-shaped
reservoir and screw caps lined with Teflon®-faced silicone disks.

6.4.4

Powder funnels -- glass.

6.4.5

Chromatographic columns for the silica and alumina
chromatography -- 1 cm ID x 10 cm long and 1 cm ID x
30 cm long with 250-mL reservoir and equipped with TFE
stopcocks.

6.4.6

Chromatographic column for the Carbopak cleanup -disposable 5-mL graduated glass pipets, 6 to 7 mm ID.

6.4.7

Glass rods.

6.4.8

Carborundum boiling chips -- Extracted for 6 hr in a
Soxhlet apparatus with benzene and air dried.

6.4.9

Glass wool, silanized (Supelco) -- Extract with methylene
chloride and hexane and air dry before use.

6.4.10

Glassware cleaning procedure -- All glassware used for
these analyses will be cleaned via the following procedure. Wash the glassware in soap and water, rinse with
copious amounts of tap water, distilled water, and
distilled-in-glass acetone, in that order. Immediately
prior to use, the glassware should be rinsed with
distilled-in-glass quality solvents: methylene chloride,
toluene, and hexane. The glassware should be allowed
to dry fully.
As an added precuation, all glassware will be marked
with a unique code that should be noted in the extraction and cleanup procedures for each sample. This
glassware tracking will allow background results from
specific glassware to be documented.
After use, each piece of glassware should be rinsed
with the last solvent used in it, followed by a rinse
with toluene, then acetone, before transferring it to
the glassware washing facility.

A-10

�7.

REAGENTS AND STANDARD SOLUTIONS
7.1

Column Chromatography

Reagents

7.1.1

Alumina, acidic (Biorad, AG-4) — Extract the alumina
in a Soxhlet apparatus with methylene chloride for 18 h
(minimum of two cycles per hour). Air dry and activate
it by heating in a foil-covered glass container for 24 h
at 190°C.

7.1.2

Silica gel -- High purity grade, type 60, 70-230 mesh;
extract the silica gel in a Soxhlet apparatus with
methylene chloride for 10 h (minimum of 2 cycles per
hour). Air dry and activate it by heating in a foilcovered glass container for 24 h at 130°C.

7.1.3

Silica gel impregnated with 40% (by weight) sulfuric
acid -- Add two parts (by weight) concentrated sulfuric
acid to three parts (by weight) silica gel (extracted
and activated) (e.g., 40 g of H2S04 plus 60 g of silica
gel) in a glass screw-cap bottle. Tumble for 5 to 6 h,
shaking occasionally until free of lumps.

7.1.4

Sulfuric acid, concentrated — ACS grade, specific
gravity 1.84.

7.1.5

Graphitized carbon black (Carbopack C, Supelco), surface of approximately 12 m2/g, 80/100 mesh -- Mix thoroughly 3.6 g of Carbopack C and 16.4 g of Celite 545®
in a 40-mL vial. Activate at 130°C for 6 h. Store in
a desiccator.

7.1.6

Celite 545® (Fischer Scientific), reagent grade, or
equivalent.

7.2

Desiccating agents — Sodium sulfate; granular, anhydrous. Before
use extract with methylene chloride for 16 h (minimum of two cycles per hour), air dry and then muffle for ^ 4 h in a shallow
tray at 400°C. Let it cool in a desiccator and store in oven at
130°C.

7.3

Solvents -- High purity, distilled in glass: methylene chloride,
toluene, benzene, cyclohexane, methanol, acetone, hexane; reagent
grade: tridecane. High purity solvents are dispensed from Teflon®
squirt bottles.

7.4

Concentration Calibration Solutions (Table 2)
Eight tridecane solutions containing native calibration standards,
13
C12-labeled internal quantisation standards, and two internal
recovery standards are required. The complete compound list is

A-11

�CO

o Ln
Ln CM

l—I r H r H i —I T —( C \ J C \ J C N J C \ I C \ J C \ I C \ I C s J C \ J C \ J L T ) L n

1 CM

CJ&gt;
Q
.

to
o

CM

CM

to
o

ooooiDLnLnmo

to

c
o

o
to

-p
3

c
o

O
OO

c.
o
rO

s-

u

o

rH rH rH rH CM

O Ln

o

c
o

i—( T—1 rH rH CM

to
o

rH rH rH rH CM

CM

O O O O O O O O O O O O O O O O O

ooooLninLnLno

1—lrHrHrHrHCMCMCMCMCMCMCMCMCMCMLnLn

rH i—I rH rH CM

oo

O)

CD
(J

c
o
o

o
o

C_J

o

ooooLnunLnLno
LnmLnLncMCMCMCMLn
T-HrHrHrHrHrHrHrHrHrHCMCM

C_3

c.

CM

CM

to
o

+J
ro
s-

Ln CM

i—Ir-lr-I T —I t —4 C \ J C S J C S I C X J C \ J C \ J C \ J C v J C \ I C \ I L n L n

CO

rO
C_3

CM

1—I i—1 i— 1 i—I T —1 i— 1 r-1 i—l i —I r H C M C N J

CM

00000000000000000

to

ooooooooooooooooo

O Ln
ID CM

CM

CM

CM

C3 Ll_
(~*\

CD
-Q
rO

a u_ u_
o oo

QC3OLL.L1_L1_L1_C_3OO

a a a o a o o. a. a. a.

3
O
Q.

r_3c_3c_5n:^x:3;3i^^cooocr&gt;
o u _ a &gt; a ) 0 ) i i i i i i i &gt; &gt; &gt;
caoQ-Q-Q-oooocricoooo-ioor^f^-co .
C-3 C_3 I
I
I
o * . * . * * * . * . * ! * . * ! *

litation

0
C3

O
t_3
(—

3

in

-a
c c
S*» C2 ' '

c

CMCMrHi—ICMi—IrHrHrHi—IrHCMrHi—IrHOO

1—1

^\

0

C_3

0
Q

o Q a. a.

u_ 0 0
o X X
0 3C ^ CO
ai

o
X

00

a i

oo

f~^ CT*

•s

r-~ in &lt;J2
to ^&gt; &lt;d- *d-

00 CO r--.

0)

r-.

c
S-

v . * . ^ » . ^ . « . « ^ « t # . A ^ i ^ ^

u_
o
1—

C_3
O)

u_

0

!.
-

r-~ CO CO CO ro CO CO
1—
CO CO CM CM CM CM CM CM

1— CO
1

a&gt;

CO CO

a

i-

o

ro T3

CM CM i—t rH rH i-H rH rH
1
1
1
1
0J 0J 0 C1 CM CN IN &lt;N &lt;N

c_&gt; c_&gt;
CO

O

CO CO

C_3 O
CO CO

c
i.

rH

C
ro

to

O 000

:0 "0 CO •o

(—H

*^

CM CM
rH i—1
I 1
&lt;N CM

c_&gt; o

CO CO
T-H

TH

�given in Table 2. The native 2,3,7,8-TCDD is supplied as a certified standard solution from the U.S. EPA QA Reference Materials
Branch. All other native compounds were supplied in crystalline
form by Cambridge Isotope Laboratories (Woburn, MA). 13C12~
Labeled internal quantitation standards were supplied in solution
in n-nonane by Cambridge Isotope Laboratories. Portions of the
native standards were accurately weighed to the nearest 0.001 mg
with a Cahn 27 electrobalance and dissolved in toluene.
7.5

Column Performance Check Mixture
The column performance check mixture consists of several TCDD
isomers which will be used to document the separation of 2,3,7,8TCDD from all other isomers. This solution will contain TCDDs
(A) eluting closely to 2,3,7,8-TCDD, and the first- (F) and lastel uting (L) TCDDs.
Analyte

Approximate amount per ampule
10
10
10
10
10
10
10
10

Unlabeled 2,3,7,8-TCDD
13
C12-2,3,7,8-TCDD
1,2,3,4-TCDD (A)
1,4,7,8-TCDD (A)
1,2,3,7-TCDD (A)
1,2,3,8-TCDD (A)
1,3,6,8-TCDD (F)
1,2,8,9-TCDD (L)
7.6

ng
ng
ng
ng
ng
ng
ng
ng

Spiking Solutions
Three solutions are prepared using the same stock as in Section
7.4. A native standard solution and a 13C12 internal quantitation standard solution are prepared in isooctane (Tables 3 and
4). A recovery standard solution is prepared in tridecane (Table 4). Samples are spiked with 100 uL of internal quantitation
standard solution and final sample extracts are spiked with 10 (jL
of internal recovery standard solution.

8.

HIGH RESOLUTION GAS CHROMATOGRAPHY/MASS

SPECTROMETRY PERFORMANCE CRITERIA

Samples and standards are analyzed by using a Carlo Erba MFC500 gas chromatography (GC) coupled to a Kratos MS50TC double-focusing mass spectrometer (MS) to be operated in the electron impact mode. The HRGC/MS interface is simply a direct connection of the fused silica HRGC column to
the ion source of the MS via a heated interface oven. Data acquisition
and processing are controlled by a Finnigan-MAT Incos 2300 data system.

A-13

�Table 3. Native Spiking Solution3
Concentration
(pg/jjL)

Compound
2,3,7,8-TCDD
2,3,7,8-TCDF
1,2,3,7,8-PeCDD
1,2,3,7,8-PeCDF
2,3,4,7,8-PeCDF

5
5
5
5
5

1,2,3,4,7,8-HxCDD
1,2,3,6,7,8-HxCDD
1,2,3,7,8,9-HxCDD

12.5
12.5
12.5

1,2,3,4,7,8-HxCDF
1,2,3,6,7,8-HxCDF
1,2,3,7,8,9-HxCDF
2,3,4,6,7,8-HxCDF
1,2,3,4,6,7,8-HpCDD
1,2,3,4,6,7,8-HpCDF
1,2,3,4,7,8,9-HpCDF
OCDD
OCDF

12.5
12.5
12.5
12.5
12.5
12.5
12.5
25
25

a

Prepared in isooctane.

A-14

�Table 4.

Internal Standard Spiking Solutions
Concentration
(pg/uL)

Compound
Internal Quantitation Standards3
13
C12-2,3,7,8-TCDD

5

13

5

13

5

13

5

C12-2,3,7,8-TCDF

C12-l,2,3,7,8-PeCDD
C12-l,2,3,7,8-PeCDF

13

12.5

13

12.5

13

12.5

13

12.5

C12-l,2,3,6,7,8-HxCDD
C12-l,2,3,4,7,8-HxCDF
C12-l,2,3,4,6,7,8-HpCDD

C12-l,2,3,4,6,7,8-HpCDF

13

C12-OCDD

25

Internal Recovery Standard
13
C12-1,2,3,4-TCDD
13

C12-l,2,3,7,8,9-HxCDD

^Prepared in isooctane.
Prepared in tridecane.

A-15

50
125

�8.1

HRGC/MS Analysis of PCDD/PCDF
Single run selected ion monitoring (SIM) analysis of the tetrachloro through octachloro-dioxins and furans is carried out with
the instrumental conditions and parameters outlined in Table 5.
For each HRGC/MS run, five distinct groups of ions, which correspond to each chlorine level, are sequentially monitored. These
ion descriptors are shown in Table 6. The masses of the two most
abundant ions in the molecular ion cluster of each dioxin and furan
and isotopically labeled standard are monitored. In addition,
the masses corresponding to the molecular ions of the hexachloro
through decachlorodiphenyl ethers (PCDEs) are monitored to aid in
the confirmation of positive furan results. Interference from
the presence of PCDE is noted by coincident response to the characteristic ions for PCDFs. A lock mass, m/z 381 from PFK (perfluorokerosene), is used to observe and correct any magnet/instrument
drift during the analysis.
8.1.1

Tuning and Mass Calibration
The mass spectrometer is tuned on a daily basis to
yield optimum sensitivity and peak shape using an ion
peak (m/z 381) from PFK. The resolution is visually
monitored and maintained at S 3,000 (10% valley definition) to provide adequate noise rejection while maintaining good ion transmission.
Mass calibration of the mass spectrometer for the HRGC/MS
analysis of PCDD/PCDF is carried out on a daily basis.
The magnetic field is adjusted to pass m/z 300 at full
accelerating voltage. PFK is admitted to the MS and an
accelerating voltage scan from 8,000 to 4,000 V is acquired by the data system. This corresponds to an effective mass range of 301 to 593 amu. Upon completion of
a successful calibration step, the five ion descriptors
shown in Table 6 are updated to reflect the new mass
calibration.

8.1.2

Ion Descriptor Switching
The ion descriptors shown in Table 6 are sequentially
monitored during a PCDD/PCDF analysis to cover the retention windows of each chlorination level. The retention windows and hence the descriptor switch points are
determined initially and whenever a new HRGC column is
installed by injection of a mixture of PCDD and PCDF
congeners. Daily adjustment of the descriptor switch
times are performed when careful monitoring of the standard retention times shows this to be necessary. The
descriptors are designed to ensure acquisition of all
isomers of each homolog.

A-16

�Table 5. HRGC/LRMS Operating Conditions for PCDD/PCDF Analysis
Mass spectrometer
8,000 V
500 uA
70 eV
-1,800 V

Accelerating voltage:
Trap current:
Electron energy:
Electron multiplier voltage:
Source temperature:
Resolution:
Overall SIM cycle time:

280°C
^ 3,000 (10% valley definition)
1s

Gas chromatograph
Column coating:
Film thickness:
Column dimensions:
He linear velocity:
He head pressure:

DB-5
0.25 urn
60 m x 0.25 mm ID
~ 25 cm/sec
1.75 kg/cm2 (25 psi)

Injection type:
Split flow:
Purge flow:
Injector temperature:
Interface temperature:
Injection size:
Initial temperature:
Initial time:
Temperature program:

Splitless, 45 s

30 mL/min
6 mL/min
270°C
300°C
1-2 uL
200°C
2 min
200°C to 330°C at 5°C/min

A-17

�Table 6.

Ions Monitored for HRGC/MS of PCDD/PCDF

Descriptor
Al

Mass

ID

303.902
305.899
315.942
317.939
319.897
321.894
331.937
333.934
373.840
380.976

TCDF
13

C12-TCDF

TCDD
13

C12-TCDD

HxCDPE
PFK (lock mass)
A2

TCDF
TCDD
PeCDF
13

C12-PeCDF

PeCDD
13

C12-PeCDD

PFK (lock mass)
HpCDPE
A3

Nominal dwell
time (sec)

HxCDF
PFK (lock mass)
13
C12-HxCDF
HxCDD
13

C12-HxCDD

OCDPE

A-18

0.090
0.090
0.090
0.090
0.090
0.090
0.090
0.090
0.090
0.090

303.902
305.899
319.897
321.894
337.863
339.860
349.903
351.900
353.858
355.855
365.898
367.895
380.976
407.801

0.045
0.045
0.045
0.045
0.045
0.045
0.045
0.045
0.045
0.045
0.045
0.045
0.035
0.035

373.821
375.818
380.976
385.861
387.858
389.816
391.813
401.856
403.853
443.759

0.080
0.080
0.080
0.080
0.080
0.080
0.080
0.080
0.080
0.080

�Table 6 (continued)
Descriptor
A4

Mass

ID

380.976
389.816
391.813
407.782
409.779
419.822
421.819
423.777
425.774
435.817
437.814
429.768
431.765
477.720

HpCDF
C12-HpCDF

HpCDD
13
37

C12-HpCDD

Cl4-HpCDD

NCDPE
A5

PFK (lock mass)
OCDF
13

C12-OCDF

OCDD
13

C12-OCDD

DCDPE

A-19

0.040
0.040
0.040
0.040
0.040
0.040
0.040
0.040
0.040
0.040
0.040
0.040
0.040
0.040

380.976
441.743
443.740
453.783
455.780
457.738
459.735
469.779
471.776
511.681

PFK (lock mass)
HxCDD

13

Nominal dwell
time (sec)

0.06
0.07
0.07
0.07
0.07
0.07
0.07
0.07
0.07
0.06

�8.1.3

HRGC Column Performance (60-m DB-5)
The HRGC column performance must be demonstrated at the
start of each 12-h analysis period.
8.1.3.1

Inject 1 uL of the column performance check
solution (Section 7.5) and acquire selected
ion monitoring (SIM) data for m/z 320, 322,
332, and 334.

8.1.3.2

The chromatographic peak separation between
2,3,7,8-TCDD and the peaks representing
any other TCDD isomers should be resolved
with a valley of 30-60%, where
Valley % = ( / ) 1 0
xy(0)
x = measured height of the valley between
the chromatographic peak corresponding to 2,3,7,8-TCDD and the peak of
the nearest TCDD isomer; and
y = the peak height of 2,3,7,8-TCDD.
Figure 2 is an example of the separation of
a TCDD isomer mixture and the calculation
of isomer resolution.
It is the responsibility of the laboratory
to verify the conditions suitable for the
appropriate resolution of 2,3,7,8-TCDD from
all other TCDD isomers. The column performance check solution also contains the TCDD
isomers eluting first and last under the
analytical conditions specified in this
protocol, thus defining the retention time
window for total TCDD determination. Any
individual selected ion current profile or
the reconstructed total ion current
(m/z 320 + m/z 322) consititutes an acceptable form of data presentation.

8.1.4

Initial Calibration for PCDD/PCDF Analysis
Initial calibration is required before any samples are
analyzed for PCDD/PCDF. Initial calibration is also
required if any routine calibration does not meet the
required criteria listed in Section 8.1.7.
8.1.4.1

Tune and calibrate the instrument with PFK
as outlined in Section 8.1.1.

A-20

�TCDD Isomer Mixture

78.7

2, 3, 7, 8.-TCDD

2359290.

1, 2, 3, 4-/1, 2, 3, 7-/L 2, 3, 8- TCDD
319.856
&lt;*= 0.500

320

100.0

2998270.
•*- x 100% = 29%
Y

322

y\

A

321.855
± 0.500

X = 10 mm

59.6

1785850.
Q2-2, 3, 7, 8,-TCDD

f\&gt;

331.851
± 0.500

332

75.3

2256890.

334

333.850
± 0.500

28:00

28:24

Figure 2.

28:48

29:12

29:36

30:00

30:24

30:48

Example of the separation of 2,3,7,8-TCDD from other TCDD
isomers on a 60 m DB-5 column.

Time

�8.1.4.2

8.1.4.3

Using the HRGC and MS conditions in Table 5 and the SIM monitoring descriptors
in Table 6, analyze a 1-uL aliquot of each
of the six concentration calibration solutions in triplicate.

8.1.4.4

Compute the relative response factors (RRFs)
for each analyte in the concentration calibration solution using the criteria for
positive identification of PCDD/PCDF's
given in Section 14.1 and the computational methods in Section 14.2.

8.1.4.5

Compute the means and their respective
relative standard deviations (% RSD) for
the RRFs from each triplicate analysis for
each analyte in the standard.

8.1.4.6

8.1.5

Six of the eight concentration calibration
solutions listed in Table 2 will be analyzed
for the initial calibration phase. These
must include solutions CS4 through CSS
(Table 2). The analyst may select any of
the remaining solutions for demonstrating
calibration at the upper concentration
range.

Calculate the grand means (RRF) and their
respective RSDs using the six mean RRFs
for each analyte.

Criteria for Acceptable Initial Calibration
8.1.5.1

The % RSD for the response factors for each
triplicate analysis of a single concentration calibration standard for each analyte
must be less than ± 30% except for the TCDD
and TCDF, which must be less than ± 20%.

8.1.5.2

The variation of the mean RRFs for the
six concentration calibrated standards
(Section 8.1.5.1) must be less than 30%
except for the TCDD and TCDF which must
be less than 20%.

8.1.5.3

The SIM traces for all ions used for quantitation must present a signal-to-noise
(S/N) ratio of ^ 2.5. This includes analytes and isotopically labeled standards.

A-22

�8.1.5.4

Isotopic ratios must be within ± 20% of
the theoretical values (see Table 7).
NOTE: If the criteria for acceptable calibration listed above have been met, the
RRF can be considered independent of the
analyte quantity for the calibration concentration range. The grand mean RRF from
the initial calibration for unlabeled PCDD/
PCDFs and for the isotopically labeled
standards will be used for all calculations until routine calibration criteria
(Section 8.1.7) are no longer met. At such
time, new mean RRFs will be calculated from
a new set of six triplicate determinations.

8.1.6

Routine Calibrations
Routine calibrations must be performed at the beginning
of every day before actual sample analyses are performed
and as the last injection of every day.
8.1.6.1

8.1.6.2

8.1.7

Inject 1 uL of the concentration calibration solution CS 7 (see Table 2) as the
initial calibration check on each analysis
day. It is recommended that the analyst
select a concentration calibration solution that brackets the sample concentrations
observed on a single analysis date as the
last injection of each analysis date.
Compute the RRFs for each analyte in the
concentration calibration solution using
the criteria for positive identification
of PCDD/Fs given in Section 14.1 and the
computational methods in Section 14.2.

Criteria for Acceptable Routine Calibration
8.1.7.1

The measured RRF for all analytes must be
within ± 30% of the grand mean values established by triplicate analysis of the
calibration concentration solutions, except for TCDD and TCDF, which must be
within ± 20% of the mean values established
in the initial calibration step.

8.1.7.2

Isotopic ratios must be within ± 20% of the
theoretical value for each analyte and isotopically labeled standard (see Table 7).

A-23

�Table 7. Ion Ratios for HRGC/LRMS Analysis of PCDD/PCDF
Compound
TCDF
13
C12-TCDF
TCDD
13
C12-TCDD
PeCDF
13
Cl2-PeCDF
PeCDD
13
Cl2-PeCDD
HxCDF
13
Cl2-HxCDF
HxCDD
13
Cl2-HxCDD
HpCDF
13
Cl2-HpCDF
HpCDD
13
Cl2-HpCDD
OCDF
13
C12-OCDF
OCDD
13
C12-OCDD

Ions monitored

Theoretical ratio

304/306
316/318
320/322
332/334
338/340
350/352
354/356
366/368
374/376
386/388
390/392
402/404
408/410
420/422
424/426
436/438
442/444
454/456
458/460
470/472

0.76
0.76
0.76
0.76
0.61
0.61
0.61
0.61
1.22
1.22
1.22
1. 22
1.02
1.02
1.02
1.02
0.87
0.87
0.87
0.87

A-24

Acceptabl e range

0.61
0.61
0.61
0.61
0.49
0.49
0.49
0.49
0.98
0.98

-

0.91
0.91
0.91
0.91
0.73
0.73
0.73
0.73

1.46
1.46
0.98 - 1.46
0.98 - 1.46

0.82 - 1.22
0.82 - 1.22
0.82 - 1.22

0.82
0.70
0.70
0.70
0.70

-

1.22
1.04
1.04
1.04
1.04

�8.1.7.3

8.2

If any of the above criteria is not met,
a second attempt may be made before repeating the entire initialization process.

HRGC/HRMS Analysis (Isomer Specific TCDD Analysis)
Isomer specific analysis for 2,3,7,8-TCDD is carried out with the
instrumental conditions and parameters shown in Table 8. In addition to monitoring the masses of the most abundant molecular ions
of TCDD, an ion corresponding to the loss of COC1 from the molecular ion is monitored for verification purposes. Mass spectrometer
resolution is maintained at or above 10,000 (10% valley definition)
in order to increase the specificity of the analysis.
8.2.1

Tuning and Mass Calibration
8.2.1.1

The mass spectrometer must be operated in
the electron (impact) ionization mode.
Static resolving power of at least 10,000
(10% valley) must be demonstrated before
any analysis of a set of samples is performed. Static resolution checks must be
performed at the beginning and at the end
of each 12-h period of operation. However, it is recommended that a visual
check (i.e., not documented) of the static
resolution be made before and after each
analysis.

8.2.1.2

The MS shall be tuned daily using PFK to
yield a resolution of at least 10,000 (10%
valley) and optimal response at m/z 254.986.
This step is followed by calibration of an
accelerating voltage scan of PFK beginning
at m/z 254 (typical calibration range is
255 to 493 amu). Other voltage scans from
the same data file are used to establish
and document both the resolution at m/z
316.983 and the mass measurement accuracy
at m/z 330.979.

8.2.1.3

Following calibration, the SIM experiment
descriptor is updated to reflect the new
calibration. Six masses (see Table 8) are
monitored by scanning ^ m/10,000 amu (atomic
mass units) over each mass. The total cycle
time is kept to 1 s. The m/z 280.983 ion
from PFK is used as a lock mass because it
is the most abundant PFK ion within the
range of m/z 255 to 334 and therefore permits the use of low partial pressures of
PFK, which minimizes PFK interferences at
the analytical masses.

A-25

�Table 8. HRGC/HRMS Operating Conditions

Mass spectrometer
8,000 V
500 MA
70 eV
2,000 V
280° C
10,000 (10% valley definition)

Accelerating voltage:
Trap current:

Electron energy:
Electron multiplier voltage:
Source temperature:
Resolution:
SIM Parameters

Identity
TCDD-COC1
TCDD
TCDD
13
Ci2-TCDD
13
C12-TCDD
PFK (lock mass)

Mass

Nominal dwell times (s)

0.15
0.15
0.15
0.15
0.15
0.10

258.930
319.897
321.894
331.937
333.934
280.983

Overall SIM cycle time = 1 s
Gas chromatograph
Column coating:
Film Thickness:
Column dimensions:

CP-Sil 88
0.2 Mm
50 m x 0.22 mm ID

Helium linear velocity:
Helium head pressure:

~ 25 cm/s 2
1.75 kg/cm (25 psi)

Injection type:
Split flow:
Purge flow:
Injector temperature:
Interface temperature:
Injection size:
Initial temperature:
Initial time:
Temperature program:

Splitless, 45 s
30 mL/min
6 mL/min
270°C
240°C
2 ML
200°C

1 min
200°C to 240°C at 4°C/min

A-26

�8.2.2

Mass Measurement and Resolution Check
Using a PFK molecular leak, tune the instrument to meet
the minimum required resolving power of 10,000 (10% valley)
at m/z 254.986 (or any other mass reasonably close to
m/z 259). Calibrate the voltage sweep at least across
the mass range m/z 259 to m/z 334 and verify that m/z
330.979 from PFK (or any other mass close to m/z 334)
is measured within ± 5 ppm (i.e., 1.7 mmu, if m/z 331
is chosen) using m/z 254.986 as a reference. Documentation of the mass resolution must then be accomplished
by recording the peak profile of the PFK reference peak
m/z 318.979 (or any other reference peak at a mass close
to m/z 320/322). The format of the peak profile representation must allow manual determination of the resolution;
i.e., the horizontal axis must be a calibrated mass scale
(amu or ppm per division). The results of the peak width
measurement (performed at 5% of the maximum which corresponds to the 10% valley definition) must appear on the
hard copy and cannot exceed 100 ppm (or 31.9 mmu if m/z
319 is the chosen reference ion).

8.2.3

HRGC Column Performance (50-m CP Sil 88/60-m SP-2330)
Prior to any HRGC/HRMS analysis of calibration solutions
or samples for 2,3,7,8-TCDD, the resolution of the HRGC
columns must be documented to be within allowable limits
in order to provide conditions adequate for unambiguous
isomer-specific analysis of 2,3,7,8-TCDD. This column
performance check must be demonstrated at the start of
each 12-h analysis period.
8.2.3.1

Inject 2 uL of the column performance check
solution and acquire selected ion monitoring (SIM) data for m/z 258.930, 319.897,
321.894, 331.937, and 333.934 within a
total cycle time of ^ 1 s (Table 8).

8.2.3.2

The chromatographic peak separation between
2,3,7,8-TCDD and the peaks representing
any other TCDD isomers must be resolved
with a valley of ^ 25%, where
Valley % = (x/y)(100)
x = measured height of the valley between
the chromatographic peak corresponding to 2,3,7,8-TCDD and the peak of
the nearest TCDD isomer; and
y = the peak height of 2,3,7,8-TCDD.

A-27

�8.2.3.3

8.2.3.4

8.2.4

If the above resolution requirement is not
met, corrective action must be taken and
acceptable resolution documented prior to
any further analyses. Corrective action
may include removal of the first meter of
the HRGC column, replacement or clearing
of the injector port, or complete replacement of the GC column.
The column performance check solution also
contains the TCDD isomers eluting first
and last under the analytical conditions
specified in this protocol, thus defining
the retention time window for total TCDD
determination. The peaks representing
2,3,7,8-TCDD and the first and the last
eluting TCDD isomer should be labeled and
identified as such on the chromatograms (F
and L, respectively). Any individual selected ion current profile or the reconstructed total ion current (m/z 259 + m/z
320 + m/z 322) constitutes an acceptable
form of data presentation.

Initial Calibration for HRGC/HRMS 2,3,7,8-TCDD Analysis
Initial calibration is required before any samples are
analyzed for 2,3,7,8-TCDD. Initial calibration is also
required if any routine calibration does not meet the
required criteria listed in Section 8.2.6.
8.2.4.1

At least six of the concentration calibration solutions listed in Table 2 must be
utilized for the initial calibration.
These must include solutions CS4 through
CSS. The analyst may select any of the
remaining solutions for demonstrating calibration at the upper concentration range.

8.2.4.2

Tune and calibrate the instrument with PFK
as described in Section 8.2.1.

8.2.4.3

Inject 1 uL of the column performance check
solution (Section 8.2.3) and acquire SIM
mass spectra data for m/z 258.930, 319.897,
321.894, 331.937, and 333.934 using a total
cycle time of ^ 1 s (see Table 8). The
laboratory must not perform any further
analysis until it has been demonstrated
and documented that the criterion listed
in Section 8.2.3.2 has been met.

A-28

�8.2.4.4

8.2.4.5

Calculate the RRFs for unlabeled 2,3,7,8TCDD relative to 13C12-2,3,7,8-TCDD and
the RRF for 13C12-2,3,7,8-TCDD relative to
13
C12-1,2,3,4-TCDD using the criteria for
positive identification of TCDD by HRGC/
HRMS given in Section 14.1 and the computational methods in Section 14.2.

8.2.4.6

Calculate the six means (RRFs) and their
respective relative standard deviations
(% RSD) for the response factors from each
of the triplicate analyses for both unlabeled and 13C12-2,3,7,8-TCDD.

8.2.4.7

8.2.5

Using the same GC and MS conditions (Table 8) that produced acceptable results
with the column performance check solution, analyze a 1-uL aliquot of each of
the six concentration calibration solutions in triplicate.

Calculate the grand mean RRFs and their
respective relative standard deviations
( RSD) using the six mean RRFs.
%

Criteria for Acceptable Initial Calibration
The criteria listed below for acceptable calibration
must be met before analysis of any sample is performed.
8.2.5.1

The percent relative standard deviation
(RSD) for the response factors from each
of the triplicate analyses of a single concentration calibration standard for both unlabeled and 13C12-2,3,7,8-TCDD must be
less than 20%.

8.2.5.2

The variation of the mean RRFs from the
six concentration calibration standards
unlabeled and 13C12-2,3,7,8-TCDD must be
less than 20% RSD.

8.2.5.3

SIM traces for 2,3,7,8-TCDD must present a
signal-to-noise ratio of s 2.5 for m/z
258.930, m/z 319.897, and m/z 321.894.

8.2.5.4

SIM traces for 13C12-2,3,7,8-TCDD must
present a signal-to-noise ratio ^2.5 for
m/z 331.937 and m/z 333.934.

8.2.5.5

Isotopic ratios for 320/322 and 332/334
must be within the allowed range (0.61 to
0.91).

A-29

�NOTE: If the criteria for acceptable calibration listed above have been met, the
RRF can be considered independent of the
analyte quantity for the calibration concentration range. The grand mean RRF from
the initial calibration for unlabeled
2,3,7,8-TCDD and for 13C12-2,3,7,8-TCDD
will be used for all calculations until
routine calibration criteria (Section 8.2.6)
are no longer met. At such time, new mean
RRFs will be calculated from a new set of
six triplicate determinations.
8.2.6

Routine Calibrations
Routine calibrations must be performed at the beginning
of a 12-h period after successful mass resolution and
HRGC column performance check runs and before analysis
of actual samples. The response factor calibration
must also be verified at the end of each analysis date.
8.2.6.1

8.2.7

Inject 1 uL of the concentration calibration solution (CS7, Table 2) which contains
2.5 pg/uL of unlabeled 2,3,7,8-TCDD, 50.0
pg/uL of 13C12-2,3,7,8-TCDD, and 50 pg/uL
of 13C12-1,2,3,4-TCDD. Using the same HRGC/
MS/DS conditions as used in Table 8, determine and document acceptable calibration
as provided below.

Criteria for Acceptable Routine Calibration
The following criteria must be met before further analysis is performed. If these criteria are not met, corrective action must be taken and the instrument must be
recalibrated.
8.2.7.1

The measured RRF for unlabeled 2,3,7,8-TCDD
must be within 20% of the mean values established in the initial calibration by triplicate analyses of concentration calibration solutions.

8.2.7.2

The measured RRF for 13C12-2,3,7,8-TCDD
must be within 20% of the mean value established by triplicate analysis of the concentration calibration solutions during
the initial calibration.

A-30

�8.2.7.3

Isotopic ratios must be within the allowed
range (0.61 to 0.90).

8.2.7.4

If one of the above criteria is not satisfied, a second attempt can be made before
repeating the entire initialization process.
NOTE: An initial calibration must be carried out whenever the routine calibration
solution is replaced by a new one from a
different lot.

9.

QUALITY CONTROL PROCEDURES
9.1

Summary of QC Analyses
9.1.1

Initial and routine calibration and instrument performance checks.

9.1.2

Analysis of a batch of samples with accompanying QC
analyses:
Sample batch -- 10 NHATS adipose tissue samples plus
additional QC analyses including 1 method blank, a control tissue and a spiked tissue sample.
"Blind" QC (external QC) samples may be submitted by an
external source (quality assurance group or independent
laboratory) and included among the batch of samples.
Blind samples include spiked samples, unidentified duplicates, and performance evaluation samples.

9.2

Performance Evaluation Solutions -- Included among the samples in
every third batch will be a solution provided by the quality control coordinator containing known amounts of unlabeled 2,3,7,8TCDD and/or other PCDD/PCDF isomers. The accuracy of measurements for performance evaluation samples should be in the range
of 70-130%.

9.3

Column Performance Check Solutions
9.3.1

At the beginning of each 12-h period during which samples are to be analyzed, an aliquot of the HRGC column
performance check solution shall be analyzed to demonstrate adequate HRGC resolution for selected TCDD isomers.

A-31

�9.4

Method Blanks
9.4.1

A minimum of one method blank is generated with each
batch of samples. A method blank is generated by performing all steps detailed in the analytical procedure
using all reagents, standards, equipment, apparatus,
glassware, and solvents that would be used for a sample
analysis, but omit addition of the adipose tissue.
9.4.1.1

The method blank must contain the same
amounts of Carbon-13 labeled internal
quantitation standards that are added to
samples before bulk lipid cleanup.

9.4.1.2

An acceptable method blank exhibits no
positive response for any of the characteristic ions monitored.
9.4.1.2.1

If the above criterion is not
met, solvents, reagents, spiking solutions, apparatus, and
glassware are checked to locate
and eliminate the source of
contamination before any samples
are extracted and analyzed.

9.4.1.2.2

If new batches of reagents or
solvents contain interfering
contaminants, purify or discard them.

9.5

Control Samples -- Control samples are prepared from a bulk sample(s) of human adipose tissue or similar matrix (e.g., porcine
fat). This material is prepared by blending the tissue with
methylene chloride, drying the extract by eluting through anhydrous sodium sulfate, and removing the methylene chloride using
rotoevaporation at elevated temperatures (80°C). The evaporation
process should be extended to ensure all traces of the extraction
solvent have been removed. The resulting oily matrix (lipid) is
subdivided into 10-g aliquots which are analyzed with each sample
batch. The results of the individual analysis will be used to
give a measure of precision from batch to batch over an entire
program. Sufficient tissue should be extracted to provide a
homogeneous lipid matrix that can be used over the total analysis
program. Enough lipid matrix is necessary to prepare the spiked
samples describe in Section 9.6.

9.6

Spiked Samples — Spiked lipid samples are prepared using a portion of the homogenized lipid described in Section 9.5. Sufficient spiked lipid matrix is prepared to provide a minimum of one
spiked sample per sample batch. It is recommended that a minimum

A-32

�of three spiked levels of the matrix are prepared ranging from 10
to 50 times the estimated limit of detection for each compound.
Each analysis of spiked sample must be accompanied by analysis of
a control sample in order to make the necessary corrections for
background contribution before determining the accuracy of the
method (Equation 9-1).
A
fw\ mn&lt;v Cone, spiked sample-cone, control sample Eq 9 n1,
,.
K
Accuracy ( ) = 100% x
%
Spike level
' "
9.7

9.8

10.

Duplicate Sample Analysis -- When possible a duplicate analysis
of specific samples is included in the sample batch as an additional measure of method precision. It is suggested that the
total tissue sample is extracted to isolate lipids material and
then subdivided for duplicate analysis. Precision is calculated
as relative percent difference (RPD) where the differences in the
duplicate measurements (for each analyte) is divided by the average of the two measurements and multiplied by 100%.
External Samples — Samples submitted as blinds to the analyst
may consist of either performance solutions of PCDD and PCDF congeners or spiked sample matrices. These performance solutions or
samples should be submitted by a source external to the analytical
program (QA unit of analysis laboratory or independent laboratory).
Performance audit solutions are intended to evaluate instrument
calibration and quantisation procedures. Spiked blind samples
must be accompanied by the corresponding unspiked samples to correct concentrations for background concentration. The blind
spiked samples are intended to evaluate the total analytical procedure. The analyst must keep in mind that it is necessary to
compare differences in standard sources for each type of external
sample.

SAMPLE PRESERVATION AND HANDLING
All adipose tissue samples must be maintained at less than -20°C from
time of collection. The analyst should instruct the collaborator collecting the sample(s) to avoid the use of chlorinated materials. Samples are handled using stainless steel forceps, spatulas, or scissors.
Aliquots of samples removed from sample bottles not used for analysis
are disposed rather than returned to the sample vial. All sample bottles (glass) are cleaned as specified in Section 6.4.10. Teflon®-lined
caps should be used. As with any biological sample, the analyst should
avoid any undue exposure.

11.

SAMPLE EXTRACTION
11.1

Extraction of Adipose Tissue
11.1.1

Accurately weigh to the nearest 0.01 g a 10-g portion
of a frozen adipose tissue sample into a culture tube
(2.2 x 15 cm).
Note:

Sample size may be smaller, depending on availability.

A-33

�11.1.2

Addition of internal quantitation standards
Allow the adipose tissue specimen to reach room temperature and then add the carbon-13 internal quantitation
spiking solution (Section 7.6) such that it delivers
500 to 2,500 pg of each of the surrogates specified in
Table 4 in a 100-uL volume.

11.1.3
11.1.4

Allow the mixture to separate and decant the methylene
chloride extract from the residual solid material using
a disposable pipette. The methylene chloride is eluted
through a filter funnel containing a plug of clean glass
wool and 5 to 10 g of anhydrous sodium sulfate. The
dried extract is collected in a 100-mL volumetric flask.

11.1.5

A second 10-mL aliquot of methylene chloride is added
to the sample and homogenized for 1 min. The methylene
chloride is decanted, dried, and transferred to the
100-mL volumetric flask as specified in Section 11.1.3

11.1.6

The culture tube is rinsed with at least two additional
aliquots (10 mL each) of methylene chloride, and the
entire contents are transferred to the filter funnel
containing the anhydrous sodium sulfate. The filter
funnel and contents are rinsed with additional methylene
chloride (20 to 40 mL). The total eluent from the filter funnel is collected in the 100-mL volumetric flask.
Discard the sodium sulfate.

11.1.7

11.2

Add 10 mL of methylene chloride and homogenize the mixture for approximately 1 min with a Tekmar Tissuemizer®.

The final volume of the extract for each sample is adjusted to 100 mL in the volumetric flask using methylene
chloride.

Lipid Determination
11.2.1

Preweigh a clean 1-dram glass vial to the nearest
0.0001 g using an analytical balance tared to zero.

11.2.2

Accurately transfer 1.0 mL of the final extract (100 mL)
from Section 11.1.7 to the 1-dram vial. Reduce the volume of methylene chloride from the extract using a water
bath (50-60°C) gentle stream of purified nitrogen until
an oil residue remains.

A-34

�11.2.3

Accurately weigh the 1-dram vial and residue to the
nearest 0.0001 g and calculate the weight of lipid
present in the vial based on difference. Nitrogen
blow-down is continued until a constant weight is
achieved.

11.2.4

Calculate the percent lipid content of the original
sample to the nearest 0.1% as shown in Equation 11-1.

" I D * FYT
Lipid content, LC ( ) = w
%
x 100%
v
AT
AL

Eq. 11-1

where: W.R = weight of the lipid residue to the
nearest 0.0001 g calculated from
Section 11.2.3;
= total volume of the extract in mL from
Section 11.1.6 (100.0 ml);
WAT = weight of the original adipose tissue
samples to the nearest 0.01 g from
Section 11.1.1; and
V..

11.2.5
11.3

= volume of the aliquot of the final extract in ml used for the quantitative
measure of the lipid residue (1.0 mL).

Record the lipid residue measured in Section 11.2.3 and
the percent lipid content calculated from Section 11.2.4.

Extract Concentration
11.3.1

Quantitatively transfer the remaining extract volume
(99.0 mL) to a 500-mL Erlenmeyer flask. Rinse the volumetric flask with 20 to 30 mL of additional methylene
chloride to ensure quantitative transfer.

11.3.2

Place the Erlenmeyer flask on a hot plate at 40°C to
remove solvent until an oily residue remains.

12. CLEANUP PROCEDURES
12.1

Bulk Lipid Removal
12.1.1

Add a total of 200 mL of rrhexane to the spiked lipid
residue in the 500-mL Erlenmeyer flask.

A-35

�12.1.2

Slowly add, with stirring, 100 g of the 40% w/w sulfuric
acid impregnated silica gel (Section 7.1.3). Stir with
a magnetic stir-plate for 2 h.

12.1.3

Allow solids to settle and decant liquid through a powder
funnel containing 20 g of anhydrous sodium sulfate and
collect in a 500-mL sample bottle.

12.1.4

Rinse solids with two 50-mL portions of hexane. Stir
each rinse for 15 min, decant, and dry by elution
through sodium sulfate combining the hexane extracts
from Section 12.1.3.

12.1.5

After the rinses have gone through the sodium sulfate,
rinse the sodium sulfate with an additional 25 ml of
hexane and combine with the hexane extracts from Section 12.1.4.

12.1.6

Prepare an acidic silica column as follows: Pack a
1 cm x 10 cm chromatographic column with a glass wool
plug, add approximately 25 ml of hexane, add 1.0 g of
silica gel (Section 7.1.2) and allow to settle, then
add 4.0 g of 40% w/w sulfuric acid impregnated silica
gel (Section 7.1.3) and allow to settle. Pack a second
chromatographic column (1 cm x 30 cm) with a glass wool
plug, add approximately 25 mL of hexane, add 6.0 g of
acidic alumina (Section 7.1.1), and allow to settle and
then top with a 1-cm layer of sodium sulfate (Section
7.2). Elute the excess hexane solvent through the
columns until the solvent level reaches the top of the
chromatographic packing. Inspect columns to ensure they
are free of channels and air bubbles. Wash the alumina
column with 40 ml of 50% v/v methylene chloride/hexane.
Remove the methylene chloride from the adsorbent by
eluting the column with an additional 100 mL of hexane.
Elute the excess solvent from the column until the
solvent level reaches the top of the sodium sulfate layer.

12.1.7

Quantitatively transfer the hexane extract from the
Erlenmeyer flask (Sections 12.1.3 through 12.1.5) to
the silica gel column reservoir. Allow the hexane extract to percolate through the column and collect in a
KD concentrator.

12.1.8

Complete the elution of the extract from the silica gel
column with 50 ml of hexane in the KD concentrator.
Concentrate the eluate to approximately 1.0 ml, using
nitrogen blow-down as necessary.

A-36

�Note: If the 40% sulfuric acid/silica gel is noted to
be highly discolored throughout the length of the adsorbent bed it is necessary to repeat the cleaning procedure beginning with Section 12.1.1.
12.2

Separation of Chemical Interferences
12.2.1

Transfer the concentrate (1.0 mL) to the top of the
alumina column. Rinse the K-D assembly with two 1.0-mL
portions of hexane and transfer the rinses to the top
of the alumina column. Elute the alumina column with
18 mL of hexane until the hexane level is just below
the top of the sodium sulfate. Discard the eluate.
Columns must not be allowed to reach dryness (i.e., a
solvent "head" must be maintained).

12.2.2

Place 30 ml of 20% (v/v) methylene chloride in hexane
on top of the alumina and elute the TCDDs from the column. Collect this fraction in a 50-mL culture tube.

12.2.3

Prepare an 18% Carbopak C/Celite 545® mixture by thoroughly mixing 3.6 g of Carbopak C (80/100 mesh) and
16.4 g of Celite 545® in a 40-mL vial. Activate at
130°C for 6 h. Store in a desiccator. Cut off a clean
5-mL disposable glass pipet (6 to 7 mm ID) at the 4-mL
mark. Insert a plug of glass wool and push to the 2-mL
mark. Add 500 mg of the activated Carbopak/Celite mixture followed by another glass wool plug. Using two
glass rods, push both glass wool plugs simultaneously
towards the Carbopak/Celite mixture and gently compress
the Carbopak/Celite plug to a length of 3 to 3.5 cm.
Pre-elute the column with 2 ml of toluene followed by
1 ml of 75:20:5 methylene chloride/methanol/ benzene,
1 ml of 1:1 cyclohexane in methylene chloride, and 2 mL
of hexane. The flow rate should be less than 0.5 mL/min.
While the column is still wet with hexane, add the entire
eluate (30 ml) from the alumina column (Section 12.2.2)
to the top of the column. Rinse the culture tube which
contained the extract twice with 1 mL of hexane and add
the rinsates to the top of the column. Elute the column
sequentially with two 1-mL aliquots of hexane, 1 mL of
1:1 cyclohexane in methylene chloride, and I mL of
75:20:5 methylene chloride/methanol/benzene. Turn the
column upside down and elute the PCDD/PCDF fraction with
20 mL of toluene into 6-dram vial.

12.2.4

Using a stream of nitrogen, reduce the toluene volume
to approximately 1 mL. Carefully transfer the concentrate into a 1-mL mini vial and reduce the volume to
about 200 (jL using a stream of nitrogen.

A-37

�12.2.5

Rinse the concentrator tube with three washings using
500 uL of 1% toluene in methylene chloride. Concentrate to 200-500 |jL and add 10 |jL of the tridecane
solution containing the internal recovery standard and
store the sample in a refrigerator until HRGC/MS analysis.

12.2.6

Immediately prior to analysis, using a gentle stream of
nitrogen at room temperature, remove toluene and methylene
chloride. Submit sample to HRGC/MS once a stable 10 uL
volume of tridecane is attained.

13. ANALYTICAL PROCEDURES

13.1

HRGC/MS Analysis for PCDD/PCDF
13.1.1

Once routine calibration criteria are met, the instrument is ready for sample analysis. Prior to the first
sample, a blank injection of tridecane should be analyzed
to document system cleanliness. If any evidence of system contamination is found, corrective action must be
taken and another tridecane blank analyzed.
The typical daily sequence of injections is shown in
Table 9 and Figure 3.
Note: Syringe Technique -- Congeners of PCDD/PCDF in the
syringes used for HRGC/MS analysis can be problematic unless the syringes are properly handled between samples.
The following procedure has been found to be very effective for PCDD/PCDF removal from contaminated syringes
and will be used throughout these analyses.
• Rinse the syringe 10 times with isooctane.
Fill the syringe with toluene and sonicate syringe
and plunger in toluene for 5 min and repeat at least
twice.
• Rinse the syringe 10 times with tridecane and pull
up 1 pL of clean tridecane.
• Syringe is ready for use.
At no time should air be introduced into the HRGC column
by using an air plug in the syringe. The oxygen present
in the air plug will quickly degrade a nonbonded GC phase.

13.1.2

Inject a 1-uL aliquot of the extract into the GC, operated under the conditions previously used (Section 8.1)
to produce acceptable results with the performance check
solution.
A-38

�Table 9. Typical Daily Sequence for PCDD/PCDF Analysis
1. Tune and calibrate mass scale versus perfluorokerosene (PFK).

2. Inject column performance mixture.
3. Inject concentration calibration solution 2.5 to 12.5 pg/nL (CS-7)
solution.
4. Inject blank (tridecane).
5. Inject samples 1 through "N".
6

Inject concentration calibration solution 2.5 to 12.5 pg/pL (CS-7)
solution or other concentration calibration solutions CS1 to CSS to
bracket observed sample concentration.

A-39

�INSTRUMENTAL ANALYSIS
Instrument Mass Calibration vs PFK

Mass Resolution Check

1
Column Performance Evaluation

Does Column
Performance Meet
Minimum Resolution
Requirements?

No

Adjust Column
Length or Install
New Column

Calibration Standard Analysis

Do Relative
Response Factors Meet
Criteria Based on Initial
Calibrations ?

No

Reanalyze or Prepare Fresh
Calibration Standards and
Calibration Curve

Yes

Proceed with Sample Analysis

Figure 3.

Daily QA procedures for proceeding with sample analysis.

A-40

�13.1.3

Acquire SIM data according to the same acquisition and
MS operating conditions previously used (Section 8.1)
to determine the relative response factors.
13.1.3.1
13.1.3.2

13.2

Acquire SIM data for the characteristic
ions designated in Table 6.
Instrument performance shall be monitored
by examining and recording the peak areas
for the recovery standard, 13C12-1,2,3,4-TCDD.
If this area should decrease to less than
50% of the calibration standard, sample
analyses shall be stopped until the problem
is found and corrected.

HRGC/HRMS Confirmation of 2,3,7,8-TCDD
The presence of 2,3,7,8-TCDD observed through the general PCDD
and PCDF procedure should be confirmed using HRGC/HRMS (resolution 10,000).
13.2.1

Once the daily criteria of mass calibration, mass resolution, HRGC performance, and routine calibration are
met and documented, the instrument is ready for sample
analysis. Prior to the first sample, a blank injection
of tridecane will be made to document system cleanliness.
The typical daily schedule for HRGC/HRMS analysis of
TCDD is shown in Table 10 and Figure 3.

13.2.2

Inject a 1-uL aliquot of the extract into the GC, operated under the conditions previously used (Section 8.2)
to produce acceptable results with the column performance
check solution.

13.2.3

Acquire SIM data according to Section 8.2.4.3. Use the
same acquisition and MS operating conditions previously
used to determine the relative response factors.
13.2.3.1

Acquire SIM data for the following selected
characteristic ions:
m/z

Compound

258.930

TCDD - COC1

319.897

Unlabeled TCDD

321.894

Unlabeled TCDD

331.937

13
C12-2,3,7,8-TCDD,
13
C12-1,2,3,4-TCDD

333.934

13
C12-2,3,7,8-TCDD,
13
C12-1,2,3,4-TCDD

A-41

�Table 10. Typical Daily Schedule for HRGC/HRMS Analysis of TCDD

1. Tune and calibrate mass scale.
2. Perform mass measurement check and mass resolution check.
3. Inject column performance check solution.
4. Inject the routine concentration calibration solution (CS7) and confirm
response factor consistency.
5. Inject tridecane blank.
6. Inject samples 1 through "N".
7. Inject concentration calibration solution and confirm response factor
consistency.
8. Mass resolution check.

A-42

�14.

DATA REDUCTION

In this section, the
the analysis of data
HRGC/HRMS method for
qualitative criteria
14.1

procedures for the data reduction are outlined for
from both the HRGC/MS method for PCDD/PCDF and the
2,3,7,8-TCDD. Figure 4 presents a schematic of the
for identifying PCDDs and PCDFs.

Qualitative Identification
14.1.1

14.1.2

The ion current intensities for a particular PCDD/PCDF
must be ^ 2.5 times the noise level (S/N ^ 2.5) for
positive identification of that isomer.

14.1.3

The integrated ion current ratios of the analytical
masses for a particular PCDD/PCDF must fall within the
ranges shown in Table 7.

14.1.4
14.2

The ion current responses for each mass for a particular
PCDD/PCDF analyte must be within ± 1 s to attain positive identification of that analyte. For example,
m/z 338 and m/z 340 must have maximum peak responses
that are within ± 1 s to be positively identified as
a pentachlorodibenzofuran.

The recovery of the internal quantisation standards
should be between 50 and 115%.

Quantitative Calculations
14.2.1

Relative response factors for native PCDD and PCDF
analytes (RRF). RRFs are calculated from the data obtained during the analysis of concentration calibration
solutions using the following formula:

A

•r

STD
IS
RRF = .b'U r i;&gt;
tt
U
IS ' STD

where A... = the
,,,
ion
For
sum
m/z

Eq. 14-1

sum of the areas of the integrated
abundances for the analyte in question.
example, for TCDD, ASTD would be the
of the integrated ion abundances for
320 and 322;

A,,, = the sum of the areas of the integrated ion
abundances for the labeled PCDD/F used as
the internal quantisation standard for the
above analyte. For example, for 13C12~
2,3,7,8-TCDD, A JS would be the sum of the
integrated ion abundance for m/z 332 and 334.
Cc-rn = concentration of the analyte in pg/(jL;

A-43

�HRGC/MS-SIMData

Response to
Characteristic Molecular
Ions within the Appropriate
Homolog Retention
Window?

Report Compounds as
Not Detected (ND)
Calculate Sample LOP

Characteristic
Ion Ratios within ±20%
Theoretical?

Response Due to
Coextracted Interference

Response
Corresponds to Specific
Isomer Retention
Time?

Quantitate Compound
as Per Protocol
Report as Isomer Unknown

Quantitate Specific Isomer as per Protocol

Figure 4. Qualitative criteria for identifying
PCDDs and PCDFs.

A-44

�GIS = concentration of the internal quantisation
standard in pg/uL; and
Table 11 provides the pairing of target analytes to
internal quantitation standards for determining RRF
values for PCDD and PCDF compounds.
14.2.2

Relative response factors for the internal quantitation
standards (RRF,&lt;.)- The RRF TS values are calculated from
data obtained auring the analysis of concentration calibration solutions using the following formula.
C

Eq. 14-2

~ RS
A XL
x
M
RS IS

where ATC. and CT&lt;; are defined as given in Section 14.2.1
1:&gt;
i:&gt;
and
CRS = concentrations of the internal recovery
standard in pg/uL; and
Apc; = the sum of the areas of the integrated ion
5
abundances for the labeled PCDD (13C121,2,3,4-TCDD or 13C12-l,2,3,7,8,9-HxCDD).
For example, for 13C12-1,2,3,4-TCDD, A R$
would be the sum of the integrated ion
abundance for m/z 332 and 334.
Refer to Table 11 for pairing of the internal quantitation standards with the appropriate internal recovery
standard.
14.2.3

Concentrations of sample components. Figure 5 presents
a schematic for quantitation of PCDDs and PCDFs which
meet the criteria specified in Section 14.1. Calculate
the concentration of PCDD/Fs in sample extracts using
the formula:
A -.«nn~ " QT C . i r\n
X
Csampl e A sampl e » IS 100
Eq. 14-3
IS RRF wAT • LC
•

where C

, = the lipid adjusted concentration of PCDD or
sample
congener 1n pg/g.

A

, = sum of the integrated ion abundances determined for the PCDD/PCDF in question;

sample

AIS = sum of the integrated ion abundances determined for the labeled PCDD/F used as the
internal quantitation standard for the above
analyte;

A-45

�Table 11. Target Analyte/Internal Quantitation Standard and Internal
Quantisation Standard/Internal Recovery Standard Pairs
Internal standards
Quantitation

Target analyte
2,3,7,8-TCDD

13

13

2,3,7,8-TCDF

13

13

1,2,3,7,8-PeCDF

13

13

2,3,4,7,8-PeCDF

13

13

1,2,3,7,8-PeCDD

13

13

1,2,3,4,7,8-HxCDF

13

13

1,2,3,6,7,8-HxCDF

13

13

2,3,4,6,7,8-HxCDF

13

13

1,2,3,7,8,9-HxCDF

13

13

1,2,3,4,7,8-HxCDD

13

13

1,2,3,6,7,8-HxCDD

13

13

1,2,3,7,8,9-HxCDD

13

13

1,2,3,4,6,7,8-HpCDF

13

13

1,2,3,4,7,8,9-HpCDF

13

13

1,2,3,4,6,7,8-HpCDD

13

13

OCDF

13

13

OCDD

13

13

Recovery

C12-2,3,7,8-TCDD

C12-2,3,7,8-TCDF
C12-l,2,3,7,8-PeCDF

C12-l,2,3,7,8-PeCDF
C12-l,2,3,7,8-PeCDD

C12-l,2,3,4,7,8-HxCDF
C12-l,2,3,4,7,8-HxCDF

C12-l,2,3,4,7,8-HxCDF
C12-l,2,3,4,7,8-HxCDF
C12-l,2,3,6,7,8-HxCDD

C12-l,2,3,6,7,8-HxCDD
C12-l,2,3,6,7,8-HxCDD

C12-l,2,3,4,6,7,8-HpCDF

C12-l,2,3,4,6,7,8-HpCDF
C12-l,2,3,4,6,7,8-HpCDD
C12-OCDD

C12-1,2,3,4-TCDD
C12-1,2,3,4-TCDD

C12-1,2,3,4-TCDD
C12-1,2,3,4-TCDD
C12-1,2,3,4-TCDD

C12-l,2,3,7,8,9-HxCDD

C12-l,2,3,7,8,9-HxCDD

C12-l,2,3,7,8,9-HxCDD
C12-l,2,3,7,8,9-HxCDD
C12-l,2,3,7,8,9-HxCDD
C12-l,2,3,7,8,9-HxCDD
C12-l,2,3,7,8,9-HxCDD
C12-l,2,3,7,8,9-HxCDD

C12-l,2,3,7,8,9-HxCDD
C12-l,2,3,7,8,9-HxCDD
C12-l,2,3,7,8,9-HxCDD

C12-OCDD

C12-l,2,3,7,8,9-HxCDD

A-46

�QUANTITATION

HRGC/MS-SIMData

Response
Meets Al I
Qualitative
Criteria ?

Report as Not Detected
Calculate Sample LOD

Response
&gt;2.5times
S/N?

Response
&gt;10 times
S/N?

Calculate as per Protocol
Report as Trace (tr) Value

Quantitate as per Protocol
Report as Positive Quantifiable Value

Figure 5. Procedure for quantitation of PCDDs and PCDFs
in human adipose tissue.

A-47

�QIS = the amount (total pg) of the labeled internal
quantisation standard added to the sample
prior to extraction;
RRF = relative response factor of the above
analyte relative to its labeled internal
quantitation standard determined from the
initial triplicate calibration;
WAT = weight (g) of original adipose tissue
sample; and
LC = percent extractable lipid determined from
Eq. 11-1.
Refer to Table 11 for pairing of target analytes with
the appropraite internal quantitation standard.
Quantitative data should be classified to indicate the
intensity of the signal response. Suggested qualifiers
include: not detected, ND (signal-to-noise ratio is
less than 2.5); trace, TR (signal-to-noise ratio is
greater than or equal to 2.5 but less than 10); and
positive quantifiable, PQ (signal-to-noise ratio is
greater than or equal to 10).
14.2.4

Recovery of internal quantitation standards. Calculate
the recovery of the labeled internal quantitation standards measured in the final extract using the formula:
A IS • X0
Internal Quant. Std. _
RS
.
,. .
fl0

Percent Recovery

AR$ - Q J$ • RRF

1UU

f

tq

' 1^4

where AT{. = sum of the integrated ion abundances determined for the labeled PCDD/PCDF internal
quantitation standard in question;
A0&lt;- = sum of the integrated ion abundances deterKb
mined for m/z 332 and m/z 334 of 13C121,2,3,4-TCDD or m/z 390 and m/z 392 of
13
C13-l,2,3,7,8,9-HxCDD (recovery standards)
QR&lt;- = amount (pg) of the respective recovery
standard, added to the final extract;
QTC. = amount (pg) the labeled internal quantitation standard added to the sample prior to
extraction; and

A-48

�= relative response factor for the labeled
internal quantitation standard in question
relative to the internal recovery standard.
This value shall be the RRF determined from
the initial calibration.
Refer to Table 11 for pairing of the internal quantitation standards with the appropriate target analytes.
Note: The result of calculations as presented in Section 14.2 may be off by as much as 1% due to the fact
that 1 ml of the final 100 ml volume from the extraction was used for lipid determination.
14.3

Estimated Method Detection Limit
Estimated
where (1)
sponse is
sponse is

method detection limits must be calculated in situations
no response is noted for a specific congener; (2) a renoted but ion ratios are incorrect; and (3) where a requantitated as a trace value.

14.3.1

For samples in which no unlabeled PCDD or PCDF is detected, calculate the estimated minimum detectable concentration. The background area is determined by integrating the ion abundances for the characteristic ions
in the appropriate region and relating the product area
to an estimated concentration that would produce that
product area.
Use the formula:

2.5

sample
RRF

"IS

Eq. 14-5

where C p = estimated concentration of unlabeled PCDD
or PCDF required to produce A
,;
sample

'IS

sum of integrated ion abundances or peak
heights for the characteristic ions of the
unlabeled PCDD or PCDF isomer in the same
group of ^ 5 scans used to measure A JS ; and
sum of integrated ion abundances for the
appropriate ions characteristic of the respective internal quantitation standard.

Qyc&gt; RRF, and W.T retain the definitions previously
stated in Section 14.2. Alternatively, if peak height
measurements are used for quantification, measure the
estimated detection limit by the peak height of the noise
in the 2,3,7,8-TCDD RT window.
A-49

�14.3.2

14.3.3

15.

For samples for which a response at the retention time
of a specific PCDD or PCDF congener is noted, but the
qualitative criteria for ion ratios are outside the
acceptable range (Table 7), the estimated detection
level is calculated as given in Eq. 14.3 except the
values are qualified as not detected, ND, and the
concentration is reported in parenthesis.
If a response for a specific PCDD or PCDF congener is
qualified as a trace, TR, value (signal to noise is
greater than or equal to 2.5 but less than 10) the
analyst must also provide an estimated method detection
limit. This is accomplished by using the observed signal to noise on either side of the response and calculating as given in Eq. 14-5.

REPORTING AND DOCUMENTATION

All data should be reported on an individual sample basis using the data
report format shown in Figure 6. The analyst is required to maintain
all raw data, calculations, and control charts in a format as to allow a
complete external data review. Suggested data formats for tracing calculations are provided in Figure 7.

A-50

�P&gt;g. 1 ot 1

U.S. ENVIRONMENTAL PROTECTION AGENCY
OFFICE OF TOXIC SUBSTANCES
EXPOSURE EVALUATION DIVISION (TS-798)
WASHINGTON, DC 20460

NATIONAL HUMAN ADIPOSE TISSUE SURVEY
ANALYSIS REPORT FORM

EPA SAMPLE NUMBER.

ANALYSIS DATE

LAB NUMBER

MS ANALYST

BATCH NUMBER

REPORT DATE

_

REPORTED BY

_

NATIVE
COMPOUNDS

CONCENTRATION

DATA

(pg/g)l/

QUALIFIER!/

INTERNAL OUANTITATION
STANDARD

2.3.7.8-TCDD

1 . . . ! • ( , 1

1

2.3,7,8-TCOF

1 . . . 1*1 1 1

1:

1 ,2,3.7.8-PeCDD

1 ...!•!, 1

13

1 ,,.!•!, 1

13

2.3.4,7,8-PeCDF

1 i . i Ul

. 1

13

1.2.3.4,7.8-HxCOD

1 ,..!•( i 1

13

1 ,2.3,6.7,8-HxCDD

1 , . , ! • ! , 1

13

1,2.3,7.8,9-HxCDD

1 , • , Ul

iJ

l3

. 1

1

1,2,3.7,8-PeCDF

1,2.3,4,7.8-HxCDF

1 , . , Ul

1 ,2.3.6,7.8-HxCOF

1 , ,.!•!, 1

1 2.3 7,8.9-HxCOF

1 ...

1,2,3,4.6.7,8-HpCDD

1 , . , Ul

Ci2-'.2.3.7,8-PeCDF
Ci2-'-2'3'6'7-8-HxCDD

Ci2-l,2,3.4,7,8-HxCDF
C(2-1,2.3,4,6.718-HpCOD

C,2-'.2.3.4,a,7,8-HpCDF

30,2-0000

13

C,2-OCDF

1 . , , !•! , 1

1 ,2,3.4.6.7,8-HpCDF

Ci2-'.2.3.7.8-PeCDD

1 , . , 1*1 , 1

2.3,4.6.7,8-HxCDF

3C,2-2.3.7.8-TCDD

&gt;C12-2.3,7,8-TCDF

ULi_J

. 1

1.2.3.4,7,8,9-HpCOF

1 . . , Ul . 1

OCDO

1 , , , Ul

OCDF

1 , , , Ul , I

. 1

REMARKS

Jj Concentration reported is based on total axtractable iipid (g).
2j

ND - Not Detected. TR - Trace. PG - Positive Quantifiable.

Figure 6. Analysis report form.

A-51

SPIKED LEVEL

(pg)

PERCENT (%)
RECOVERY

�RAW DATA SUMMARY FOR DETERMINATION OF 1.2.3.7.8-PeCDD IN HUMAN ADIPOSE TISSUE

Sample
no.

Sample
weight
(xx.xx q)

Extractable
lipid
content
(XX. X %
)

Analysis
date

Amount
C12-PeCDD
(pg)

13

13

C12-PeCDO
n/z 332

13

Cl2-PeCDD
m/z 334

Ion ratio
366/368

1,2,3,7,8PeCDD
m/z 354

1,2,3,7,8
m/z 356

I

tn
ro

Value reported as concentration in extractable lipid.

Figure 7. Example of raw data summary format for the determination of
1,2,3,7,8-PeCDD in human adipose tissue.

Ion ratio
354/356

1,2,3,7,8PeCOD
cone.
(pg/g)

�TECHNICAL REPORT DATA
(Please read Inunctions on the reverse before completing)
3. RECIPIENT'S ACCESSlON&gt;NO.
I a.

NO.

EPA 560/5-86-020
S. REPORT DATE

4. 7i7LS AND SUBTITLE

Analysis for Polychlorinated Dibenzo-p_-dioxins (PCDD) and
Dibenzofurans (PCDF) in Human Adipose Tissue: Method
Evaluation Study

September 17. 1986
6. PERFORMING ORGANIZATION CODE

Midwest Research Institute

7.AUTHOR&lt;s&gt; js Stanley, RE Ayling, KM Bauer, MJ McGrath,
TM Sack, and KR Thornberg

8. PERFORMING ORGANIZATION REPORT NO.

a-JeRFOHMLNG ORGANIZATION NAME ANO ADDRESS

10. PROGRAM ELEMENT NO.

Thawest Research Institute
425 Volker Boulevard
Kansas City, MO 64110

11. CONTRACT/GRANT NO.

68-02-3938
68-02-4252

12. SPONSORING AGENCY NAME ANO ADDRESS

Field Studies Branch (TS-798)
Exposure Evaluation Division
Office of Toxic Substances
U.S.

8824-A(01)

13. TYPE OF REPORT ANO PERIOD COVERED

Final

Washinqton, DC 20460

14. SPONSORING AGENCY CODE

Environmental Prntprt.inn Aqpnr.v

13. SUPPLEMENTARY NOTES

J Remmers, Work Assignment Manager; J Breen, Project Officer
16. ABSTRACT

This report focuses on the evaluation of an HRGC/MS analytical method for determination of 2,3,7,8-substituted polychlorinated dibenzo-p_-dioxins (PCDD) and dibenzofurans
(PCDF) in human adipose tissue. This method will be used for analysis of samples from
EPA's National Human Adipose Tissue Survey (NHATS) as part of a collaborative effort between EPA's Office of Toxic Substances and the Veterans Administration. The method was
evaluated using aliquots of a bulk lipid matrix that was extracted from human adipose
tissue. The results of the replicate analysis of spiked and unspiked homogenized human
adipose tissue matrix demonstrate that the analytical method produces accurate and precise data for 17 specific 2,3,7,8-substituted PCDD and PCDF (tetra- through octachloro
homologs) congeners. The endogenous or background levels of the PCDD and PCDF congeners
in the homogenized adipose lipid matrix were estimated through regression analyses of
measured versus spiked concentrations for each compound. This unspiked matrix will be
used as a control sample with each batch of samples analyzed.

KEY WORDS ANO DOCUMENT ANALYSIS

17.

DESCRIPTORS

b.lOENTIFIERS/OPSN ENDED TERMS

C.

19. SECURITY CLASS &lt; rhu Report/

21. NO. OP PAGES

COSATt Fteid'CfOUp

D

olychlorinated dibenzo-jp_-dioxin (PCDD)
Polychlorinated dibenzofuran (PCDF)
Human adipose tissue
Method evaluation
2,3,7,8-Tetrachlorodibenzo-g-dioxin
(2,3,7,8-TCDD)
I «3.7.8-Tetrachl orodi benzofuran (2.3.7.f
13. ^ i S T P i a u T i O N STATEMENT

Release unlimited

Unclassified
20. SECURITY CLASS

Unclassified
EPA fttm 2220-1 (3-73)

145
22.

�</text>
                  </elementText>
                </elementTextContainer>
              </element>
            </elementContainer>
          </elementSet>
        </elementSetContainer>
      </file>
    </fileContainer>
    <collection collectionId="30">
      <elementSetContainer>
        <elementSet elementSetId="1">
          <name>Dublin Core</name>
          <description>The Dublin Core metadata element set is common to all Omeka records, including items, files, and collections. For more information see, http://dublincore.org/documents/dces/.</description>
          <elementContainer>
            <element elementId="50">
              <name>Title</name>
              <description>A name given to the resource</description>
              <elementTextContainer>
                <elementText elementTextId="4687">
                  <text>Alvin L. Young Collection on Agent Orange</text>
                </elementText>
              </elementTextContainer>
            </element>
            <element elementId="41">
              <name>Description</name>
              <description>An account of the resource</description>
              <elementTextContainer>
                <elementText elementTextId="49809">
                  <text>&lt;p style="margin-top: -1em; line-height: 1.2em;"&gt;The Alvin L. Young Collection on Agent Orange comprises 120 linear feet and spans the late 1800s to 2005; however, the bulk of the coverage is from the 1960s to the 1980s and there are many undated items. The collection was donated to Special Collections of the National Agricultural Library in 1985 by Dr. Alvin L. Young (1942- ). Dr. Young developed the collection as he conducted extensive research on the military defoliant Agent Orange. The collection is in good condition and includes letters, memoranda, books, reports, press releases, journal and newspaper clippings, field logs and notebooks, newsletters, maps, booklets and pamphlets, photographs, memorabilia, and audiotapes of an interview with Dr. Young.&lt;/p&gt;&#13;
&lt;p&gt;For more about this collection, &lt;a href="/exhibits/speccoll/exhibits/show/alvin-l--young-collection-on-a"&gt;view the Agent Orange Exhibit.&lt;/a&gt;&lt;/p&gt;</text>
                </elementText>
              </elementTextContainer>
            </element>
          </elementContainer>
        </elementSet>
      </elementSetContainer>
    </collection>
    <itemType itemTypeId="1">
      <name>Text</name>
      <description>A resource consisting primarily of words for reading. Examples include books, letters, dissertations, poems, newspapers, articles, archives of mailing lists. Note that facsimiles or images of texts are still of the genre Text.</description>
      <elementContainer>
        <element elementId="52">
          <name>Box</name>
          <description>The box containing the original item.</description>
          <elementTextContainer>
            <elementText elementTextId="48202">
              <text>197</text>
            </elementText>
          </elementTextContainer>
        </element>
        <element elementId="53">
          <name>Folder</name>
          <description>The folder containing the original item.</description>
          <elementTextContainer>
            <elementText elementTextId="48204">
              <text>5526</text>
            </elementText>
          </elementTextContainer>
        </element>
        <element elementId="54">
          <name>Series</name>
          <description>The series number of the original item.</description>
          <elementTextContainer>
            <elementText elementTextId="48207">
              <text>Series VIII Subseries I</text>
            </elementText>
          </elementTextContainer>
        </element>
      </elementContainer>
    </itemType>
    <elementSetContainer>
      <elementSet elementSetId="1">
        <name>Dublin Core</name>
        <description>The Dublin Core metadata element set is common to all Omeka records, including items, files, and collections. For more information see, http://dublincore.org/documents/dces/.</description>
        <elementContainer>
          <element elementId="39">
            <name>Creator</name>
            <description>An entity primarily responsible for making the resource</description>
            <elementTextContainer>
              <elementText elementTextId="48200">
                <text>Stanley, John S.</text>
              </elementText>
              <elementText elementTextId="48201">
                <text>et al.</text>
              </elementText>
            </elementTextContainer>
          </element>
          <element elementId="41">
            <name>Description</name>
            <description>An account of the resource</description>
            <elementTextContainer>
              <elementText elementTextId="48203">
                <text>&lt;strong&gt;Corporate Author: &lt;/strong&gt;Midwest Research Institute</text>
              </elementText>
            </elementTextContainer>
          </element>
          <element elementId="40">
            <name>Date</name>
            <description>A point or period of time associated with an event in the lifecycle of the resource</description>
            <elementTextContainer>
              <elementText elementTextId="48205">
                <text>1986-10-01</text>
              </elementText>
            </elementTextContainer>
          </element>
          <element elementId="50">
            <name>Title</name>
            <description>A name given to the resource</description>
            <elementTextContainer>
              <elementText elementTextId="48206">
                <text>Analysis for Polychlorinated Dibenzo-p-Dioxins (PCDD) and Dibenzofurans (PCDF) in Human Adipose Tissue: Method Evaluation Study: Final Report with attached letter transmitting the report to Alvin L. Young, from Janet C. Remmers, Field Studies Branch, Expo</text>
              </elementText>
            </elementTextContainer>
          </element>
        </elementContainer>
      </elementSet>
    </elementSetContainer>
    <tagContainer>
      <tag tagId="2">
        <name>ao_seriesVIII</name>
      </tag>
    </tagContainer>
  </item>
  <item itemId="6500" public="1" featured="0">
    <fileContainer>
      <file fileId="2315">
        <src>https://www.nal.usda.gov/exhibits/speccoll/files/original/40acfd2554f623d0f152b8286123a60b.pdf</src>
        <authentication>e2abc03f964ecc5b150083b7f6d4a72e</authentication>
        <elementSetContainer>
          <elementSet elementSetId="4">
            <name>PDF Text</name>
            <description/>
            <elementContainer>
              <element elementId="60">
                <name>Text</name>
                <description/>
                <elementTextContainer>
                  <elementText elementTextId="64264">
                    <text>Item D Number

0552

Author

Stanley, John S.

Corporate Author

Midwest Research Institute

Report/Article Title

Analysis for Polychlorinated Dibenzo-p-Dioxins and
Dibenzofurans in Human Adipose Tissue: Method
Evaluation Study: Draft Final Report with attached letter
transmitting the report to Alvin L. Young, from Janet C.
Remmers, Field Studies Branch, Exposure Evaluation
Division, United States Environmental Protection
Agency

2

Not Scanned

Journal/Book Title
Year

1986

Month/Day
Color

D

143

DOSCrtotOU NOtOS

EP/flk Prime

Contract No. 68-02-3938, Work Assignment No.
46, MRI Project No. 8501 -A(46). See Item 5526 for final
version

Tuesday, March 19,2002

Page 5522 of 5611

�A\
Sfa |

UNITED STATES ENVIRONMENTAL PROTECTION AGENCY

,/

WASHINGTON, D.C. 20460

JUNE 10, 1986
OFFICE OF
PHT1CIDES AND TOXIC SUBSTANCES

Alvin Young, Ph.D.,
Lt Col., USAF
Senior Policy Analyst for Life Sciences
Executive Office of the President
Office of Science and Technology Policy
Room 5005
New Executive Office Building
Washington, DC 20506
Dear Dr . Young:
Enclosed for your information is a report entitled,
"Analysis for Polychlorinated Dibenzo-p_-dioxins and
Dibenzofurans in Human Adipose Tissue: Method Evaluation
Study", May 30, 1986. This report includes the analytical
protocol which will be used in the EPA/VA dioxin study of
adipose tissue from veterans and nonveterans. Also included is
the method evaluation data from a single laboratory study. If
you have any comments or questions, please feel f r e e to call me
at 382-3583.
Sincerely,

fanet C. Remmers
Field Studies Branch
Exposure Evaluation Division
(TS-798)
Enclosure
cc:

M a r t i n Halper
Joseph Breen
(-11

�MIDWEST RESEARCH INSTITUTE

ANALYSIS FOR POLYCHLORINATED DIBENZQ-£-DIOXINS AND DIBENZOFURANS
IN HUMAN ADIPOSE TISSUE: METHOD EVALUATION STUDY

DRAFT FINAL REPORT

EPA Prime Contract No. 68-02-3938
Work Assignment No. 46
MRI Project No. 8501-A(46)

For

Field Studies Branch, TS-798
Office of Toxic Substances
U.S. Environmental Protection Agency
401 M Street, S.W.
Washington, DC 20460
Attn: Ms. Janet Remmers, Work Assignment Manager
Dr. Joseph J. Breen, Project Officer

MIDWEST RESEARCH INSTITUTE 425 VOLKER BOULEVARD, KANSAS CITY, MISSOURI 64110 • 816 753-7600

�ANALYSIS FOR POLYCHLORINATED DIBENZO-jD-DIOXINS AND DIBENZOFURANS
IN HUMAN ADIPOSE TISSUE: METHOD EVALUATION STUDY

by
John S. Stanley, Randy E. Ayling, Karin M. Bauer, Michael J. McGrath,
Thomas M. Sack, and Kelly R. Thornburg

DRAFT FINAL REPORT

EPA Prime Contract No. 68-02-3938
Work Assignment No. 46
MRI Project No. 8501-A(46)

For

Field Studies Branch, TS-798
Office of Toxic Substances
U.S Environmental Protection Agency
401 M Street, S.W.
Washington, DC 20460
Attn: Ms. Janet Remmers, Work Assignment Manager
Dr. Joseph J. Breen, Project Officer

MIDWEST RESEARCH INSTITUTE 425 VOLKER BOULEVARD, KANSAS CITY, MISSOURI 64110 • 816 753-7600

�DISCLAIMER

This document is a preliminary draft. It has not been released formally by
the Office of Toxic Substances, Office of Pesticides and Toxic Substances,
U.S. Environmental Protection Agency. It is being circulated for comments
on its technical merit and policy implications.

�PREFACE
This report provides a summary of the results from a method evaluation study for the determination of 2,3,7,8-substituted polychlorinated
dibenzo-p_-dioxins (PCDDs) and dibenzofurans (PCDFs) in human adipose tissues.
This method evaluation is an integral part of a collaborative program between
the U.S. Environmental Protection Agency's Office of Toxic Substances and the
Veterans Administration to determine if significant differences exist in the
2,3,7,8-substituted PCDD and/or PCDF levels in human adipose tissues for
Vietnam veterans compared to the general adult male population. The study
design will focus on specimens within EPA's National Human Adipose Tissue
Survey (NHATS) repository. The method evaluation described in this report
was necessary to establish method performance (accuracy and precision) before
proceeding with actual sample analysis.
This method evaluation study was completed under EPA Contract No.
68-02-3938, Work Assignment 46, "Analysis for Dioxins and Furans in Human
Adipose Tissue," Ms. Janet Remmers, Work Assignment Manager, and Dr. Joseph
Breen, Project Officer.
MIDWEST RESEARCH INSTITUTE

Paul C. Constant
Program Manager
Approved:

Jack Balsinger
QuaH\y Assurance Coordinator

E. Going, Director'
Chemical Sciences Department

May 30, 1986

11

�TABLE OF CONTENTS

Page
I.

Introduction

II.

Summary

III.

Recommendations

4

IV.

Experimental

5

A.
B.
C.
D.
E.
F.
G.

5
5
10
12
17
20
20

V.

1
•

Preparation of Homogenized Tissue
Analytical Standards
Analytical Procedure
HRGC/MS Analysis
Data Interpretation
Quality Assurance/Quality Control (QA/QC)
Preliminary Method Studies.

Results

23

A.. Analytical Results
B. Statistical Analysis
VI.

Quality Assurance/Quality Control (QA/QC)
A.
B.
C.
D.

VII.

3

Initial Calibration
Daily Verification of Response Factors
Blanks
Absolute Recoveries of the Internal Quantisation
Standards

References

23
23
62
62
64
64
76
81

Appendix A - Analytical Protocol for Determination of PCDDs and
PCDFs in Human Adipose Tissue

m

A-l

�LIST OF FIGURES
Figure
1

2

Page
Comparison of the HRGC/MS-SIM reconstructed ion chromatogram (RIC) from the analysis of unspiked homogenized
human adipose tissue matrix and a calibration standard
for PCDDs and PCDFs
Example of the TCDF (m/z 304) and TCDD (m/z 320)
HRGC/MS-SIM elution profiles in unspiked and spiked

human adipose
3

4

5

6

7

8

9

10

11

12

30

31

Example of the PeCDF (m/z 338) and PeCDD (m/z 354)
HRGC/MS-SIM elution profiles in unspiked and spiked
human adipose

32

Example of the HxCDF (m/z 374) and HxCDD (m/z 390)
HRGC/MS-SIM elusion profiles in unspiked and spiked
human adipose

33

Example of the HpCDF (m/z 408) and HpCDD (m/z 424)
HRGC/MS-SIM elution profiles in unspiked and spiked
human adipose

34

Examples of the OCDF (m/z 442) and OCDD (m/z 458)
HRGC/MS-SIM elution profiles in unspiked and spiked
human adipose

35

Measured concentrations versus concentrations of 2,3,7,8TCDD spiked into the homogenized human adipose lipid
matrix
.

36

Measured concentrations'versus concentrations of
1,2,3,7,8-PeCDD spiked into the homogenized human
adipose lipid matrix

37

Measured concentrations versus concentrations of
1,2,3,4,7,8-HxCDD spiked into the homogenized human
adipose lipid matrix

38

Measured concentrations versus concentrations of
1,2,3,6,7,8-HxCDD spiked into the homogenized human
adipose lipid matrix

39

Measured concentrations versus concentrations of
1,2,3,7,8,9-HxCDD spiked into the homogenized human
adipose lipid matrix

40

Measured concentrations versus concentrations of
1,2,3,4,6,7,8-HpCDD spiked into the homogenized human
adipose lipid matrix.

41

�LIST OF FIGURES (continued)
Figure
13
14
15
16
17
18
19
20
21
22
23
24
25

Page
Measured concentrations versus concentrations of OCDD
spiked into the homogenized human adipose lipid matrix. .

42

Measured concentrations versus concentrations of
2,3,7,8-TCDF spiked into the homogenized human
adipose lipid matrix

43

Measured concentrations versus concentrations of
1,2,3,7,8-PeCDF spiked into the homogenized human
adipose lipid matrix

44

Measured concentrations versus concentrations of
2,3,4,7,8-PeCDF spiked into the homogenized human
adipose lipid matrix

45

Measured concentrations versus concentrations of
1,2,3,4,7,8-HxCDF spiked into the homogenized human
adipose lipid matrix. . . . .

46

Measured concentrations versus concentrations of
1,2,3,6,7,8-HxCDF spiked into the homogenized human
adipose lipid matrix

47

Measured concentrations versus concentrations of
2,3,4,6,7,8-HxCDF spiked into the homogenized human
adipose lipid matrix

48

Measured concentrations versus concentrations of
1,2,3,7,8,9-HxCDF spiked into the homogenized human
adipose lipid matrix

49

Measured concentrations versus concentrations of
1,2,3,4,7,8,9-HpCDF spiked into the homogenized human
adipose lipid matrix

50

Measured concentrations versus concentrations of
1,2,3,4,6,7,8-HpCDF spiked into the homogenized human
adipose lipid matrix

51

Measured concentrations versus concentrations of OCDF
spiked into the homogenized human adipose lipid matrix. .

52

Method accuracy estimates as determined from the slopes
of the least squares regression lines for the 17
target PCDD and PCDF analytes

54

Control charts showing response factors by date for
2,3,7,8-TCDF and 2,3,7,8-TCDD . .

65

�LIST OF FIGURES (continued)
Figure
26
27
28
29
30
31

Page
Control charts showing response factors by date for
1,2,3,7,8-PeCDF and 2,3,4,7,8-PeCDF

66

Control chart showing response factors by date for
1,2,3,7,8-PeCDD

67

Control charts showing response factors by date for
1,2,3,4,7,8-HxCDF and 1,2,3,6,7,8-HxCDF

33
34

68

Control charts showing response factors by date for
2,3,4,6,7,8-HxCDF and 1,2,3,7,8,9-HxCDF

69

Control charts showing response factors by date for
1,2,3,4,7,8-HxCDD and 1,2,3,6,7,8-HxCDD

70

Control chart showing response factors by date for
1,2,3,7,8,9-HxCDD

32

,

71

Control charts showing response factors by date for
1,2,3,4,6,7,8-HpCDF and 1,2,3,4,7,8,9-HpCDF

72

Control chart showing response factors by date for
1,2,3,4,6,7,8-HpCDD

73

Control charts showing response factors by date for OCDF
and OCDD

74

�LIST OF TABLES
Table
1

Page
Analytical Standards Available for the Method
Evaluation Studies

7

2

Concentration Calibration Solutions

8

3

Native PCDD and PCDF Spiking Solution

9

4

Internal Standard Spiking Solutions

11

5

HRGC/LRMS Operating Conditions for PCDD/PCDF Analysis . . .

13

6

Ions Monitored for HRGC/MS Analysis of PCDD/PCDF

14

7

Typical Daily Sequence for PCDD/PCDF Analysis

16

8

Ion Ratios for HRGC/MS Analysis of PCDD/PCDF

18

9

Summary of the Results of the Sample Preparation Method
Evaluation Using Carbon-14 PCDDs

22

Spiked Versus Measured Concentrations of 2,3,7,8-TCDF
and 2,3,7,8-TCDD in Homogenized Human Adipose Lipid
Samples

24

Spiked Versus Measured Concentrations of 1,2,3,7,8-PeCDF,
2,3,4,7,8-PeCDF, and 1,2,3,7,8-PeCDD in Homogenized
Human Adipose Tissue Samples

25

Spiked Versus Measured Concentrations of 1,2,3,4,7,8-;
1,2,3,6,7,8-; 2,3,4,6,7,8-; and 1,2,3,7,8,9-HxCDF
in Homogenized Human Adipose Lipid Matrix

26

Spiked Versus Measured Concentration of 1,2,3,4,7,8-;
1,2,3,6,7,8-; and 1,2,3,7,8,9-HxCDD in Homogenized
Human Adipose Lipid Samples

27

10

11

12

13

14

Spiked Versus Measured Concentrations of 1,2,3,4,6,7,8HpCDF, 1,2,3,4,7,8,9-HpCDF, and 1,2,3,4,6,7,8-HpCDD

in Homogenized Human Adipose Lipid Samples
15

28

Spiked Versus Measured Concentrations of OCDF and OCDD
In Homogenized Human Adipose Lipid Samples

29

16

Regression Line Slopes with 95% Confidence Limits

55

17

Results of the Analysis of the Low and High Level
Native Spike Solutions.

56

vii

�LIST OF TABLES (continued)
Table

Page

18

Background Level Estimates with 95% Confidence Limits . . .

58

19

Day-to-Day Precision of Analysis of Specific Sample
Extracts for Tetra- and Pentachloro PCDF and PCDD . . . .

59

Day-to-Day Precision of Analysis of Specific Sample
Extracts for Hexa- and Heptachloro PCDF and PCDD

60

Day-to-Day Precision of Analysis of Specific Sample
Extracts for OCDF and OCDD

61

Relative Response Factors (Grand Means) Determined from
Multipoint Concentration Calibration Standards

63

Summary of Results from the Analysis of a Laboratory
Method Blank

75

20
21
22
23
24

Recovery of Radiolabeled PCDDs from Precleaned Activated

Alumina
25
26

77

Absolute Recoveries of the Internal Quantisation Standards
from the Human Adipose Lipid Matrix

78

Recovery of Carbon-14 Labeled 2,3,7,8-TCDD, 1,2,3,4,7,8HxCDD, and OCDD as a Function of Final Concentration
Conditions

80

�I.

INTRODUCTION

The Environmental Protection Agency Office of Toxic Substances
(EPA/OTS) and the Veterans Administration (VA) have established an interagency
agreement to study the level of polychlorinated dibenzo-p_-dioxins (PCDDs) and
dibenzofurans (PCDFs) in human adipose tissues. The occurrence and levels of
PCDDs and PCDFs with chlorine substitution in the 2,3,7,8 positions (especially
2,3,7,8-TCDD) of the parent molecules are of primary interest.
As part of this interagency effort, it has been proposed to use
selected adipose tissue samples that were collected for the Field Studies
Branch (FSB) of EPA's Office of Toxic Substances (OTS) through the National
Human Adipose Tissue Survey (NHATS) to determine exposure to PCDDs and PCDFs.
The available adipose tissues include specimens obtained from young men whose
age indicates that they could have served in Vietnam and could have been exposed to Agent Orange. The tissues were originally collected as part of a
broadly based and statistical random sampling of the continental United States.
The analysis of these tissues may provide information on the differences of
exposure of the general adult male population and Vietnam veterans to the
2,3,7,8-substituted PCDDs and PCDFs.
The overall objectives of the proposed EPA/VA collaborative studies

are:
1.

Evaluate the reliability, accuracy, precision, and sensitivity of a proposed method for the determination of 2,3,7,8substituted PCDDs and PCDFs (tetra- through octachloro
homologs) in human adipose tissue;

2.

Determine if these compounds can be detected in adipose tissues
of the American male adult population; and

3.

Determine if individuals with military service in Vietnam have
significantly different levels of 2,3,7,8-substituted PCDDs
and PCDFs (particularly 2,3,7,8-TCDD) than other American men.

As a prelude to this work assignment, MRI conducted an extensive
literature review of applicable analytical methods and conducted a meeting
with recognized experts in this field to identify critical aspects of analytical methodology.1'2
Based on the information gathered through the literature review and
the meeting with the recognized experts, a special report was prepared for
OTS proposing 3 a framework for an analytical method for analysis of human adipose tissues. Several studies have been completed since the issuance of that
report which reflect the advances in analytical techniques for adipose tissue
analysis.4 16 The salient features of these methods have been combined into
a single protocol for the routine analysis of tetra- through octachloro PCDDs
and PCDFs at the low-parts-per-trillion level for the EPA/VA tissue study.
This report focuses on a method evaluation study that was conducted
to achieve the first objective of the interagency agreement. Clarification

�of method performance is necessary before proceeding with the analysis of
actual samples retrieved from the NHATS repository.
This report includes a summary of the method evaluation study results (Section II). Recommendations to be implemented before proceeding with
the actual tissue samples from the NHATS repository are presented in Section
III. A description of the actual experimental procedures is provided in Section IV. Results of sample analyses are summarized in Section V, and quality
assurance/quality control (QA/QC) aspects of the study are detailed in Section
VI. Pertinent references are listed in Section VII. Appendix A contains the
detailed analytical protocol that will be followed for the analysis of the
NHATS specimens designated in the study design to be provided by EPA/VA.

�II. SUMMARY
The results of the replicate analysis of spiked and unspiked homogenized human adipose tissue matrix demonstrate that the analytical method
produces accurate and precise data for 17 specific 2,3,7,8-substituted PCDD
and PCDF (tetra- through octachloro homologs) compounds. Data are reported
for three or four replicate analyses of samples spiked at three different
concentration levels. The endogenous or background levels of the PCDD and
PCDF congeners in the homogenized adipose lipid matrix were estimated through
regression analyses of measured (found) versus spiked concentrations for each
compound,
The analytical method is capable of providing quantitative data for
tetra- through octachloro PCDD and PCDF congeners to concentration levels as
low as 1 pg/g (tetrachloro congeners). However, an interference was noted at
m/z 304 which coeluted with 2,3,7,8-TCDF, resulting in a detection level of
approximately 4 pg/g.
Average absolute recoveries of the internal quantisation standards
ranged from 52% for 13Ci2-TCDD up to 89% for 13C12-OCDD. The agreement of
the measured concentrations versus the spiked concentrations for each PCDD
and PCDF congener demonstrates that the internal standard quantisation procedure provides an accurate measure of concentration which is independent of
the absolute recovery.
Final concentration conditions were noted to have pronounced effect
on the absolute recoveries of the lower chlorinated compounds, particularly
2,3,7,8-TCDD. Experiments with carbon-14 labeled 2,3,7,8-TCDD demonstrated
that final concentration at temperatures of 55 to 60°C resulted in recoveries
as low as 54% while the same procedure conducted at ambient conditions resulted in greater than 90% recovery.
Analysis of method and reagent blanks provided information on potential artifacts in the sample preparation scheme. Additional experiments
were conducted with carbon-14 labeled PCDDs to evaluate the cleanup efficiency
and recovery of PCDDs from chromatographic materials, particularly acidic
alumina.

�III. RECOMMENDATIONS
Some minor modifications have been made in the written protocol
(Appendix A) that were not included in this phase of the method validation.
These include:
a cleanup procedure for activated acidic alumina prior to
fractionation of sample extracts to remove artifacts; and
final concentration of the sample extracts using nitrogen
blowdown at room temperature rather than heating to 55-60°C.
The spiking solutions used to prepare the spiked quality control
samples should be submitted for replicate (minimum of three/per spike level)
HRGC/MS analysis to assist the interpretation of positive or negative bias in
the accuracy of QC sample data.
The accuracy bounds should be extended to 50-130% from 50-115% as
specified in the draft quality assurance program plan.
The method should include additional internal quantisation standards
to pair with the HpCDF 13 OCDF congeners. Also, an additional internal recovand
ery standard, possibly C12-l,2,3,4,7,8-HxCDD, is required to provide better
estimates of absolute method recovery. These additional compounds, if available, will be incorporated into the method before initiating sample analyses.

�IV. EXPERIMENTAL
A. Preparation of Homogeni zed Jissue
A bulk lipid sample was prepared from the extracts of human adipose
tissue samples collected through the NHATS program. The adipose tissue samples have been stored in a deep freezer at approximately -10°C since collection. The homogenized tissue extract or bulk lipid was used in this method
evaluation study for preparation of replicate samples spiked with varying
levels of specific PCDD and PCDF isomers. This homogenized matrix will also
be used for preparing control and spiked quality control samples for the
actual NHATS sample analysis phase of the program.
A total of 2,465 g of adipose tissue was extracted, dried, and
concentrated to yield 1,652 g (62% of original weight) of homogenized lipid.
Specific procedures for preparing this matrix are described below.
The adipose tissue samples were thawed at room temperature for 1 to
2 h. Portions of the samples were added to a blender cup of a Waring® blender
and covered with methylene chloride. The volume of methylene chloride was
approximately equal to the sample volume (100 to 200 ml). This mixture was
blended at high speed for approximately 10 min, and the contents were transferred to a 500-mL Erlenmeyer flask and further blended with a Tekmar®
Tissumizer, also at high speed for 10 min. A powder funnel was plugged with
a wad of glass wool (si 1 anized, methylene chloride extracted) and filled with
~ 50 g of sodium sulfate (heated overnight to 600°C in a muffle furnace).
The sodium sulfate was wetted with methylene chloride prior to elution of the
sample extract. The dried effluents were refiltered in the same way using a
fresh bed of sodium sulfate to remove particulate and residual water.
The samples were transferred to 1-L round bottom flasks, and the
solvent was removed by rotary evaporation. The water bath on the rotary evaporator was kept at 60°C using a thermostatted heating element. Once the solvent appeared to have been removed (constant volume in flask, no visible condensation in condenser), the heating and evaporation process was continued
for at least 2 h. The flask and contents were removed and stored in a refrigerator. The extracted lipid solidified upon refrigeration and was visually
checked for homogeneity. No precipitates or phase separation was observed.
The lipid residue was allowed to liquify at room temperature and was transferred to a 4-L glass bottle with a Teflon®-lined lid.
The lipid residue was brought to room temperature and heated just
enough to allow the lipid to achieve an oily state prior to aliquotting portions for the method evaluation studies.
B. Analytical Standards
Analytical standards including native PCDD and PCDF congeners,
stable isotope (carbon-13) labeled standards and radiolabeled (carbon-14)
standards were purchased from Cambridge Isotope Laboratories, Woburn,
Massachusetts, and Pathfinder Laboratories, St. Louis, Missouri. The 2,3,7,8TCDD was received from the EPA Reference Materials Branch as a solution. The

�other native PCDD and PCOF congeners were received as 1-mg neat standards.
The stable and radio!abeled isotopes were received as solutions. Table 1
provides a summary of the standards used for this study.
Stock solutions of the individual PCDD and PCDF congeners were prepared from the neat standards. The neat materials were weighed using a Cahn
27 electrobalance calibrated versus a 1-mg (Class M) standard. The neat compounds were transferred to glass vials and were dissolved in 2.0 to 3.0 ml of
toluene (Burdick and Jackson, distilled in glass). Toluene was added to each
standard using volumetric pipettes (Class A). The OCDD required dilution to
10.0 ml using a 50:50 mixture of toluene and anisole.
A working solution consisting of the 17 native PCDD and PCDF congeners was prepared at a concentration of 2 ug/mL for the TCDD, TCDF, PeCDD,
and PeCDF congeners, 5 ug/ml for the HxCDD, HxCDF, HpCDD, and HpCDF congeners,
and 10 |jg/mL for the OCDD and OCDF. The working solution was used to prepare
both the lipid matrix spiking solution and the calibration standards.
The stable isotope labeled internal standards were obtained as^solutions at 50 (jg/mL concentration with the exception of the 13Ci2-OCDD, which
was provided at 10 |jg/mL. Separate working solutions containing mixtures of
the carbon-13 labeled PCDDs and PCDFs were prepared for use in the calibration
standards and the sample spiking solutions.
The carbon-14 radiolabeled PCDDs were used for preliminary method
evaluation studies. The specific activity of the 14C-2,3,7,8-TCDD (117.56
mCi/mmole) was high enough to allow recovery studies at spike levels equivalent to 10 pg/g for a 10^-g sample.
1. Calibration Standards
Eight concentration calibration standards containing the 17 native
and the 9 carbon-13 labeled internal standards were prepared for determining
the consistency of response factors for the native PCDDs and PCDFs versus the
corresponding carbon-13 congeners. Table 2 presents a summary of the calibration standards prepared for the method calibration study.
2. Spi king Solutions
a. Native PCDD and PCDF
A solution containing the 2,3,7,8-substituted PCDD and PCDF
congeners was prepared for spiking the homogenized lipid materials for the
method evaluation study. Table 3 specifies the levels of each of the native
PCDD and PCDF congeners present in this solution.

�Table 1. Analytical Standards Available for the Method Evaluation Studies
Compound

Source

Native
2,3,7,8-TCDD

EPA QA Reference Materials
Branch
2,3,7,8-TCDF
Cambridge Isotope Laboratories
1,2,3,7,8-PeCDD
Cambridge Isotope Laboratories
1,2,3,7,8-PeCDF
Cambridge Isotope Laboratories
2,3,4,7,8-PeCDF
Cambridge Isotope Laboratories
1,2,3,4,7,8-HxCDD
Cambridge Isotope Laboratories
1,2,3,6,7,8-HxCDD
Cambridge Isotope Laboratories
1,2,3,7,8,9-HxCDD
Cambridge Isotope Laboratories
1,2,3,4,7,8-HxCDF
Cambridge Isotope Laboratories
1,2,3,6,7,8-HxCDF
Cambridge Isotope Laboratories
1,2,3,7,8,9-HxCDF
Cambridge Isotope Laboratories
2,3,4,6,7,8-HxCDF
Cambridge Isotope Laboratories
1,2,3,4,6,7,8-HpCDD Cambridge Isotope Laboratories
1,2,3, 4,6, 7,8-HpCDF Cambridge Isotope Laboratories
1,2,3,4,7,8,9-HpCDF Cambridge Isotope Laboratories
OCDD
Cambridge Isotope Laboratories
OCDF
Cambridge Isotope Laboratories

Lot/Code
20603
AWN 1203-74/EF-903C
MLB-706-53/ED-950C
AWN-729-21/EF-953C

AWN-729-45/EF-956C
830244/ED-961C
MLB-706-47/ED-960C
MLB-706-73/ED-969C
AWN-729-20/EF-964C
MB 13106-7/EF-962-C
MB 13106-47/EF-967-C
MB 13106-3/EF-968-C
MLB-706-21/ED-971C
AWN-729-22/EF-973C
MB-13-106-77/EF-975C
8465-F-982-C/EF-982C
F2832/ED-980C

13

Ci2-Internal standards
2,3,7,8-TCDD
Cambridge
2,3,7,8-TCDF
Cambridge
1,2,3,7,8-PeCDD
Cambridge
1,2,3,7,8-PeCDF
Cambridge
1,2,3,6,7,8-HxCDD
Cambridge
1,2,3,4,7,8-HxCDF
Cambridge
1,2,3,4,6,7,8-HpCDD Cambridge
OCDD
Cambridge

Isotope
Isotope
Isotope
Isotope
Isotope
Isotope
Isotope
Isotope

Laboratories
Laboratories
Laboratories
Laboratories
Laboratories
Laboratories
Laboratories
Laboratories

R00208/ED-900
R00236/EF-904
R00241/ED-955
R00221/EF-952
R00249/ED-966C
R00234/EF-963C
R00248/ED-972
R00263/ED-981

14

Ci2"Radiolabe1ed standards
2,3,7,8-TCDD
Pathfinder Laboratories
1,2,3,4,7,8-HxCDD
Pathfinder Laboratories
OCDD
Pathfinder Laboratories
S.A. = specific activity.

S.A.a = 117.56 mCi/mmole
S.A. = 24.16 mCi/mmole
S.A. = 20.50 mCi/mmole

�ininminininininmin

o

,E

o
co
c
o

o
in

o
in

inininininininininin
m inininincMCMCMCMCMCMCM CM CM CM in in
CMCMCMCMCMeDeoeoeDeoeovDeoeoeocMCM

o o o o in in in
in in in in CM CM
CM

CD

in

o
m

o ooooinLnLninininininininocD
in mininincMCMCMCMCMCMCMCMCMCMinin

o o o o in in in
in in in m CM CM
CM

o
in

o
m

oCDOOOOOOOOCDOOOOOO
o ooooinLnininininininminoo

m
S-

,-.
,f

co

fU CJ
L)

c

C
O

«0
5-P

jjfc

u
e
o

o o o CD in in in
in m in m CM CM
CM

o o o o in in in
in in un m CM CM
CM

o
in

o
m

-a O O O CD in in in
c. in in in m CM CM
CM

o
in

o
•o in

rH rH

«o
i.

CO

co
o

CM

CM

rH r-4 rH

rH r H r H r H r H e M C M C M C M C M C M C M C M C M C M i n i n

CM

r-4 rH rH

CM

V)

T3
S-

•

oCDOOOOOOOOCDOOOOOCD
CD O O C D O O O O O O O O O O C D O O
CM cMCMCMCMinininininininmininoo
•* «t

CM

rH rH

CJ

CM

rH rH rH

T*H r~( i~H i~l t~4 i~~f r~f r~f r^l rH Csl CSJ

c co
0) CJ
(J
c
o

CM

rH rH 1-4

-M

•i—

c
Q)

o
m

rH rH .rH

o ooocDinininininininininmocD

c in
o CO

r-p-

o

o
in

m

CM

000

rHt—f r H r H r H r H r H r H r H r H C M C M

•r- CJ

(0

O

o in in m
in in in m CM CM
CM

rH r H r H r H i - H C M C M C M C M C M C M C M C M C M C M i n i n

^_)
~J CJ
^—
O

&gt;r_

JQ

CD

in

r-4 rH

inininininininininin
in inininincMCMCMCMCMCMCMCMCMCMinin

eo
eo

*.p

s_

0

CM C M C M C M C M C D C Q C D C O C D e D C D C D l O t O C M C M
rH rH

co

C

•£

O CD O o in in m
in in m m CM CM
TH

in m in in CM CM
CM

ininininininininLnm
m inininincMCMCMCMCMCMCMCMCMCMinin

•r- CJ

in
c

CM

o
m

O OO

o
IX.

C

CD

in

rH r H r H r H r H C M C M C M C M C M C M C M C M C M C M i n i n

eo
—'
^x

CD in in m
rH rH rH

oo

r-4
CO
CJ

QJ
(«-

.Q
to

a u. u.
o oa

QQQU_U_LL.U_OOCJ
Q Q Q Q Q Q C3 O.O.O.
QU_LJ_CJCJOC_)CJOOnia:ni

r-

•o

SSS^miini^zoooocn

a

a)

CO

rH rH r-4

V)

a u_
aQ

+3

c.
o
+3

to

4«&gt;
•r-

a U_
oQ

0
O
CJ

H-

U

X X

00
&gt;

-P

m

Is**.

ooi^r^r^^vor^^-^r^vD^j-^'*
f*^« CO CO ^ CO CO CO CO CO CO ^ CO CO CO

S-

Z CM C M r H r H C M r H r H i - H r H r H r H C M r H r H r H O O

0)

*

I I I
en M ev
CO

r—i

^»
i-

co oo r^ r*~ eo ^~ •3r**^ r*^ co co co co co

CO

CO

o
&lt;u

o
o
^— »

1 L_]
N IN CV I tNO

CJ CJ CJ CJ 0 CJ

CO C O C M C M C O C M C M C M C M C M C M C O C M C M C M O a
.
*

UJ

«v

CO CO CM CM CM CM CM

o

CO
rH

CO
rH

CO
rH

&lt;0

ro
-M

CJ CJ

.

o.

i.

-a
c

1
CJ CJ 3: IT 00
U. 0) &lt;J) 1 1
Q 0- 0. 00 00 rO 1 1
- '
h- 00 oo r*- r^- CD

I I

C.

CM

I

M

CJ 31 O

M

*A
Vi

rH

rH

o
o
o
i—
i
co
CM
«*

rH

i.
st\
-P
t—
LH
1—4

1

CJ
CO

00

�Table 3. Native PCDD and PCDF Spiking Solution
Compound

Concentration
(pg/nl_)

2,3,7,8-TCDD

5

2,3,7,8-TCDF

5

1,2,3,7,8-PeCDD
1,2,3,7,8-PeCDF

5
5

2,3,4,7,8-PeCDF
1,2,3,4,7,8-HxCDD

5
12.5

1,2,3,6,7,8-HxCDD

12.5

1,2,3,7,8,9-HxCDD
1,2,3,4,7,8-HxCDF

12.5
12.5

1,2,3,6,7,8-HxCDF
1,2,3,7,8,9-HxCDF

12.5
12.5

2,3,4,6,7,8-HxCDF

12.5

1,2,3,4,6,7,8-HpCDD ..

12.5

1,2,3,4,6,7,8-HpCDF
1,2,3,4,7,8,9-HpCDF

12.5
12.5

OCDD
OCDF

25
25

�b. Internal Standards
Two different internal standard spiking solutions were prepared
for quantisation of native PCDD and PCDF congeners. The compositions of each
of the spiking solutions are presented in Table 4. The internal quantisation
standards were spiked into the lipid aliquots prior to any cleanup procedures
and hence were carried throughout the method exactly as the corresponding
native congeners. The internal recovery standard was added in 10 uL of a
keeper solution (tridecane) during final extract concentration prior to analysis. The recovery standard was used to measure the absolute method recoveries
of the internal quantisation standards.
C. Analytical Procedure
The homogenized human adipose lipid matrix was allowed to come to
room temperature and then warmed in a water bath until the matrix changed to
an oily state. Approximately 10.0 g of the oily material was transferred by
pipette to preweighed glass vials, and the actual weight of the lipid was
determined to the nearest 0.01 g by difference using an analytical balance.
Four 10.00-g aliquots were spiked with 20 uL of the native spiking solution
presented in Table 3, another four aliquots were spiked with 50 uL of the same
solution, and three additional aliquots were spiked with 100 uL of native PCDD
and PCDF solution. These spikes were equivalent to concentrations ranging
from 10, 25, and 50 pg/g in the lipid matrix for the tetra- and pentachloro
PCDD and PCDF congeners up to 50, 125, and 250 pg/g for the OCDD and OCDF for
the low, medium, and high level spikes.
In addition to the spiked samples, three aliquots of the lipid
material were transferred for determining the endogenous levels of each of
the PCDD and PCDF congeners in the control matrix.
Each of the sample aliquots was fortified with 100 pL of the internal quantisation standard spiking solution (Table 4). The spiked samples
were each quantitatively transferred to 500-mL Erlenmeyer flasks using hexane.
The residues were diluted with a total of 200 ml of hexane, and
100 g of sulfuric acid (H2S04) modified silica gel (40% w/w) was added to each
solution with stirring. The mixtures were stirred for approximately 2 h, and
the supernatants were decanted and filtered through filter funnels packed with
anhydrous sodium sulfate (Na2S04). The H2S04 modified silica adsorbents were
washed with at least two additional aliquots of hexane and dried by elution
through Na2S04.
The combined hexane extracts for each sample were eluted through
columns consisting of the 40% H2S04 modified silica gel (4.0 g) and silica
gel (1.0 g). The eluates were concentrated to approximately 15 ml and added
to columns of acidic alumina (Bio-Rad, AG-4, 6.0 g). The acidic alumina columns were eluted first with 20 ml of hexane, which was collected but not analyzed, followed by elution with 30 ml of 20% methylene chloride in hexane.
The PCDDs and PCDFs were eluted from the acidic alumina using the 20% methylene chloride in hexane. The PCDDs and PCDFs in the eluates were isolated from
other chlorinated planar aromatics using columns (5-mL disposable pipettes
containing 500 mg of 18% Carbopak C and Celite-545). The Carbopak C/Celite
10

�Table 4. Internal Standard Spiking Solutions
Concentration
(pg/(jL)

Compound
Internal quantitation standard8
13

5

13

5

13

5

13

5

C12-2,3,7,8-TCDD

C12-2,3,7,8-TCDF

C12-l,2,3,7,8-PeCDD
C12-l,2,3,7,8-PeCDF

13

12.5

13

12.5

13

12.5

C12-l,2,3,6,7,8-HxCDD

C12-l,2,3,4,7,8-HxCDF

C12-1,2,3,4,6,7,8-HpCDD

13

C12-OCDD

25

Internal recovery standard
13

C12-1,2,3,4-TCDD

5

uSolution prepared in isooctane.
Solution prepared in tridecane.

11

�columns were pre-eluted with 2 ml of toluene, I mi of 75:20:5 methylene
chloride/methanol/benzene, 1 mL of 1:1 methylene chloride/cyclohexane, and
2 ml of hexane. The sample extracts (30 ml) were added to the columns, which
were eluted with 2 ml of hexane, 1 ml of 1:1 methylene chloride/cyclohexane,
and 1 ml of the 75:20:5 methylene chloride/methanol/benzene. These eluents
were collected and combined but were not analyzed. The Carbopak C/Celite
columns were turned upside down, and the PCDDs and PCDFs were eluted with
20 ml of toluene. The toluene was concentrated to less than 1 ml using flowing nitrogen and a heated water bath (55-60°C) and transferred to 1.0-mL
conical vials using a solution of 1% toluene in methylene chloride. Tridecane
(10 nD containing 500 pg of the internal recovery standard 13C12-1,2,3,4-TCDD
was added as a keeper when the solution had concentrated to approximately
200 pL. The extracts were concentrated to final volume using nitrogen and
the heated water bath.
D. HRGC/MS Analysis
The analyses of the spiked and unspiked lipid samples were completed
,using a Kratos MS50TC double-focusing magnetic sector mass spectrometer. The
determination for the tetra- through octachloro homologs was achieved in a
single analysis using the conditions described in Table 5. Table 6 provides
the characteristic ions monitored for each PCDD and PCDF homolog. As noted
from Table 6, the analysis requires five different parameter descriptions that
were switched automatically during the course of the analysis. Parameters
monitored included two characteristic molecular ions for each PCDD and PCDF
homolog and the corresponding carbon-13 labeled internal standard. In addition, a fragment ion of perfluorokerosene (PFK) was monitored throughout each
analysis to ensure that proper mass calibration was maintained. The parameter descriptors also included an ion characteristic of specific homologs of
chlorinated diphenyl ethers to demonstrate that responses meeting the qualitative criteria for specific PCDF congeners were not due to these potential
interferences.
Triplicate analyses of six of the eight calibration solutions
(Table 2) were completed, and the variability in relative response factors
across this range was calculated. The analyst was required to demonstrate on
a daily basis that the relative response factors (RRF) were in agreement
within ± 20% of the established averages for 2,3,7,8-TCDD and 2,3,7,8-TCDF
and within ± 30% of the average RRF values for the other congeners. The analyst was also required to determine column performance by analyzing a mixture
of TCDD isomers before proceeding with sample analysis. Table 7 gives an example of the typical daily sequence for PCDD/PCDF analysis.

12

�Table 5. HRGC/LRMS Operating Conditions for PCDD/PCDF Analysis
Mass spectrometer
Accelerating voltage:
Trap current:
Electron energy:
Electron multiplier voltage:
Source temperature:
Resolution:
Overall SIM cycle time:

8,000 V
500 MA
70 eV
-1,800 V
280°C
£ 3,000 (10% valley definition)
1s

Gas chromatograph
Column coating:
Film thickness:
Column dimensions:
He linear velocity:
He head pressure:

DB-5
0.25 Mm
60 m x 0.25 mm ID
* 25 cm/sec
1.75 kg/cm2 (25 psi)

Injection type:
Split flow:
Purge flow:
Injector temperature:
Interface temperature:
Injection size:
Initial temperature:
Initial time:
Temperature program:

Splitless, 45 s
30 mL/min
6 mL/min
270°C
300°C
1-2 ML
200°C
2 min
200°C to 330°C at 5°C/min

13

�Table 6. Ions Monitored for HRGC/MS Analysis of PCDD/PCDF
Descriptor
Al

ID

Mass

TCDF

303.902
305.899
315.942
317.939
319.896
321.894
331.937
333.934
373.840
380.976

0.090
0.090
0.090
0.090
0.090
0.090
0.090
0.090
0.090
0.090

303.902
305.899
319.896
321.894
337.863
337.860
349.903
351.900
353.858
355.855
365.898
367.895
380.976
407.801

0.045
0.045
0.045
0.045
0.045
0.045
0.045
0.045
0.045
0.045
0.045
0.045
0.035
0.035

HxCDF

373.821
375.819

PFK (lock mass)
13
C12-HxCDF

380.976
385.861
387.859
389.816
391.813
401.856

0.080
0.080
0.080
0.080
0.080

13

C12-TCDF

TCDD
13

C12-TCDD

HxDPE
PFK (lock mass)
A2

TCDF
TCDD
PeCDF
13

C12-PeCDF

PeCDD
13

C12-PeCDD

PFK (lock mass)
HpCDPE
A3

Nominal dwell
time (sec)

HxCDD
13

C12-HxCDD

403.853
443.759

OCDPE

14

0.080
0.080

0-. 080
0.080
0.080

�Table 6 (continued)

Descriptor
A4

ID

Mass
380.976
389.816
391.813
407.782
409.779
419.822
421.819
423.777
425.774
435.817
437.814
429.768
431.765
477.720

13

C12-HpCDF

HpCDD
13

C12-HpCDD

37

Cl4-HpCDD

NCDPE
PFK (lock mass)
OCDF
13

C12-OCDF

OCDD
13

C12-OCDD

DCDPE

15

0.040
0.040
0.040
0.040
0.040
0.040
0.040
0.040
0.040
0.040
0.040
0.040
0.040
0.040

380.976
441.743
443.740
453.784
455.781
457.738
459.735
469.779
471.776
511.681

PFK (lock mass)
HxCDD
HpCDF

A5

Nominal dwell
time (sec)

0.060
0.070
0.070
0.070
0.070
0.070
0.070
0.070
0.070
0.060

�Table 7. Typical Daily Sequence for PCDD/PCDF Analysis
1. Tune and calibrate mass scale versus perfluorokerosene (PFK).
2. Determine column performance by injecting the TCDD isomer mixture.
3. Inject concentration calibration solution 2.5 to 12.5 pg/uL (CS-7)
solution.
4. Inject blank (tridecane).
5. Inject samples 1 through "n".
6

Inject concentration calibration solution 2.5 to 12.5 pg/uL (CS-7)
solution.

16

�E. Data Interpretation
1. Qualitative
The HRGC/MS elution profiles of the tetra- through octachloro PCDD
and PCDF homologs were established through the analysis of environmental sample extract (fly ash from a municipal waste incinerator). The characteristic
ions for each homolog were plotted within the retention window established
using this mixture. The criteria for identification of a response as a PCDD
or PCDF were the coincidental response of the characteristic ions monitored
within the established retention window, and within ± 20% of the theoretical
ion ratio. Table 8 presents the range of ion ratios used for the qualitative
criteria for the specific PCDD and PCDF homologs and internal standards.
2. Quantitation
Quantisation of the specific PCDD and PCDF congeners was achieved
using the respective internal quantisation standards. For example, TCDD was
quantitated versus the 13C12-2,3,7,8-TCDD; PeCDD versus the 13C12-1,2,3,7,8PeCDD, etc. The HpCDF and OCDF responses were quantitated versus the carbon-13
labeled hepta- and octachloro dibenzo-p_-dioxin internal standards since the
corresponding dibenzofuran internal standards were not available for this
study. The absolute recovery of the internal quantisation standards was
achieved using 13C12-1,2,3,4-TCDD. A second internal recovery standard,
37
Cl4-l,2,3,4,6,7,8-HpCDD, was evaluated but was not used for recovery measurements due to interference arising from the corresponding native HpCDD.
Relative response factors (RRF) were calculated for each compound
listed in Table. 2. The RRF values were calculated as shown in Equation 1.
"crn x Cjr
STD
IS
A
H

Xc

IS x ^STD

where A

Eq. 1

= the sum of the area responses for the two characteristic ions
of the standard compound;
= the sum of the area responses for the two characteristic ions
of the corresponding internal quantisation standard;
= concentration of the internal quantisation standard (pg/|jL); and
= concentratlon

°f tne standard compound (pg/uL).

A calibration curve was established using six concentration levels
of standards; for example, the calibration curve for 2,3,7,8-TCDD was initially established with standards at concentrations of 1, 2.5, 5, 10, 50, and
100 pg/uL The 2.5 pg/uL standard was analyzed daily to verify response
factors and instrument sensitivity. The RRF values for each of the internal
quantisation standards were calculated versus the internal recovery standard,
13
C12-1,2,3,4-TCDD, using Equation 1.
17

�Table 8. Ion Ratios for HRGC/MS Analysis of PCDD/PCDF
Compound
TCDF
13
C12-TCDF
TCDD
13
C12-TCDD
PCDF
13
C12-PeCDF
PeCDD
13
C12-PeCDD
HxCDF
13
C12-HxCDF
HxCDD
13
C12-HxCDD
HpCDF
13
C12-HpCDF
HpCDD
13
C12-HpCDD
OCDF
13
C12-OCDF
OCDD
13
C12-OCDD

Ions monitored

Theoretical ratio

304/306
316/318
320/322
332/334
338/340
350/352

0.76
0.76
0.76
0.76
0.61
0.61
0.61
0.61
1.22
1.22
1.22
1.22
1.02
1.02
1.02
1.02
0.87
0.87
0.87
0.87

354/356
366/368
374/376
386/388
390/392
402/404
408/410

420/422
424/426
436/438

442/444
454/456
458/460

470/472

18

Acceptabl e range

0.61 0.61 0.61 0.61 0.49 0.49 0.49 0.49 0.96 0.96 0.96 0.96 0.82 0.82 0.82 0.82 0.70 0.70 0.70 0.70 -

0.91
0.91
0.91
0.91
0.73
0.73
0.73
0.73
1.46
1.46
1.46
1.46
1.22.
1.22
1.22
1.22
1.04
1.04
1.04
1.04

�The concentration of a PCDD or PCDF congener in a composite sample
was calculated as shown in Equation 2.
r - Asample x QIS
L
WT " A x RRF x Wt
where

Fn 9 L
tq&lt;

CWT = wet tissue concentration of the PCDD or PCDF congener in each

tissue (pg/g);

A sample = sum of the area responses for the two characteristic ions of
i
pcD[) Qy pCDp congerier;

A,o = sum of the area responses for the two characteristic ions of
the respective internal quant i tat ion standard;
QT&lt;: = amount of the internal quantisation standard added to the
i:&gt;
sample (500 pg of 13C12-TCDD or 2,500 pg of 13C12-OCDD);
RRF = the relative response factor for the PCDD or PCDF congener
from Equation 1; and
Wt = mass of the sample (grams).
The absolute recovery of the internal quantisation standard was
calculated using Equation 3.
Recovery ( ) = ,-/*
%
RS
IS
where

K
;
4

, x 100

Eq. 3

IS

ARS = sum of the area responses for the two characteristic ions of
.
the internal recovery standard, 13C12-1,2,3,4-TCDD;
QR&lt;. = amount of the internal recovery standard added to the final
extract (500 pg); and
RRF jg = response factor of the internal quantisation standard relative
to the internal recovery standard.

All data were qualified to reflect whether the compound was a positive quantifiable parameter, present as a trace value only, or was not detected. Positive quantifiable values were identified for responses greater
than 10 times background signal to noise. Trace (TR) values were assigned
to responses which were in the range of 2.5 to 10 times background signal to
noise. A value of not detected (ND) was used to reflect that a response was
not detected at greater than 2.5 times signal to noise. A limit of detection
(LOD) was calculated for all trace and not detected values using the peak

19

�height response of the respective internal standard and the average measured
signal to noise for the characteristic ions of the PCDDs and PCDFs.
F. Quality Assurance/Quality Control (QA/QC)
The QA/QC procedures included analysis of multipoint calibration
concentration standards to establish relative response factor (RRF) 'curves
for each of the 17 native PCDD and PCDF congeners. The mean RRF (RRF) values
and instrument sensitivity were verified daily by bracketing the sample analyses with an injection of a standard that ranged from 2.5 pg/uL for 2,3,7,8TCDD and 2,3,7,8-TCDF up to 12.5 pg/uL. for OCDD and OCDF. The criterion for
continuing with the sample analysis was agreement of the measured RRF value
with the mean RRF within ± 20% for 2,3,7,8-TCDD and TCDF and ± 30% for all
other PCDD and PCDF congeners.
Other activities included the analysis of laboratory method blanks
and reagent blanks and measurement of the absolute recoveries of the internal
quantisation standards.
G. Preliminary Method Studies
Prior to analysis of the homogenized human adipose lipid matrix by
HRGC/MS, several experiments were conducted to confirm that the sample preparation scheme was feasible.
1. Gravimetric Studies
The first concern was the efficient removal of up to 10 g of lipid
matrix from extracted adipose tissue. A series of experiments was conducted
with 10-g lipid aliquots to demonstrate removal of lipid using the H2S04-Si02
slurry technique. Initially, 50 g of the acid modified silica was added to
the lipid extract in 100 ml of hexane. The acid modified silica was noted to
turn dark brown immediately on contact with the lipid solution. The hexane
was recovered and the adsorbent was extracted with additional hexane. The
extracts were combined and concentrated to 5 ml with Kuderna-Danish evaporators.
The extract was eluted through a column of 4.0 g of acid modified silica and
1.0 g of silica with 45 mL of hexane. The acid modified silica was noted to
be highly discolored throughout, and the extract required a second slurry
treatment of the eluent with an additional 50 g of acid modified silica gel.
The adsorbent from the second slurry procedure was noted to discolor significantly, indicating that lipid materials had not been efficiently removed from
the first step of the procedure. The hexane supernatant from the second
slurry cleanup was reduced in volume and taken to dryness in a preweighed
glass vial. The final residue was measured at approximately 10 mg for duplicate samples, which translates into a removal efficiency of 99.9% based on
the initial 10-g aliquot.
This lipid cleanup procedure was modified such that 100 g of acid
modified silica gel was used in the initial slurry cleanup, followed by elution of the resulting extract through a column containing 4.0 g of acid modified silica and 1.0 g of silica gel. The lipid removal efficiency of duplicate samples through the cleanup procedure was determined to average 99.8%

20

�(20 to 30 mg of the initial 10-g lipid remained after cleanup). The column
cleanup step in this procedure did not exhibit any significant color change.
Thus this step of the procedure was incorporated into the method as a check
of the efficiency of lipid removal to prevent overloading of the acidic alumina fractionation column.
2. Carbon-14 Recovery Studies
The carbon-14 radiolabeled PCDD standards listed in Table 1 were
used to estimate overall method recoveries for the tetra- through octachloro
homologs prior to proceeding with the HRGC/MS evaluation. Triplicate analyses
(10-g aliquots of lipid materials) were conducted with each of the three
radiolabeled standards. The first experiment addressed the recovery of the
compounds from bulk lipid cleanup. Triplicate analyses using 10-g aliquots
were completed for the three compounds at the following concentrations:
14
C-2,3,7,8-TCDD, 10 pg/g; 14C-l,2,3,4,7,8-HxCDD, 100 pg/g; and 14C-OCDD,
250 pg/g. The results of these analyses indicated that all compounds were
recovered in the range of approximately 70 to 80%. Following this ^experiment,
the total sample preparation procedure described earlier in this re*port was
evaluated using triplicate analysis of 10-g lipid samples. Table 9 provides
a summary of the results from this study. These data indicate that overall
method recovery is limited by the initial bulk lipid removal procedure. This
assumption is based on the similar recoveries of the carbon-14 labeled compounds noted for evaluation of the bulk lipid removal step as compared to the
total sample preparation scheme.

21

�Table 9. Summary of the Results of the Sample Preparation
Method Evaluation Using Carbon-14 PCDDs
Spike
levels

Bulk lipid
removal,
recovery

Analytes

(pg/g)

Total method
recovery ( )
%

14

C-2,3,7,8-TCDD

10

68

75

14

100

79

66

250

82

76

C-l,2,3,4,7,8-HxCDD

14

C-OCDD

*

Average value for triplicate analyses taken through the total sample
preparation scheme. Precision of measurements varied by less than ± 10%
.(relative standard deviation).
Average value for triplicate analyses taken through bulk lipid cleanup
only. Precision of measurement varied by less than ± 6% (relative standard deviation).

22

�V.

RESULTS

A. Analytical Results
The analytical results for the quantisation of the 17 target PCDD
and PCDF 2,3,7,8-substituted congeners in the spiked and unspiked homogenized
human adipose lipid samples are presented in Tables 10 to 15. These data
demonstrate that 13 of the 17 congeners were definitely detected in the unspiked lipid matrix. Although 2,3,7,8-TCDF is reported as not detected, responses for the characteristic ions (m/z 304 and 306) greater than 10 times
signal to noise were noted to be coincident with the internal standard, 13C12~
2,3,7,8-TCDF. The ratio of the responses (m/z 304/306) in each of the triplicate analyses of the unspiked matrix were well outside the acceptable ratio
of 0.90 to 0.61 established in Table 8. Figure 1 provides a comparison of
the HRGC/MS-SIM responses noted for the unpsiked human adipose lipid matrix
as compared to a concentration calibration standard. Figures 2 through 6
provide examples of the individual PCDD and PCDF responses observed for the
unspiked lipid samples as compared to fortified matrices.
In general, the precision of the replicate measurements at each
spike level is good (relative standard deviations typically less than 10%)
for PCDD and PCDF congeners that were detected with responses greater than 10
times signal to noise. The precision for estimated detection limits for
1,2,3,7,8-PeCDF (Table 11), 1,2,3,7,8,9-HxCDF (Table 12), and OCDF (Table 15)
ranges from 21.6% to 43.1% as a result of little or no response at the specified retention window.
B. Statistical Analysis
The regression results for each of the 17 specific PCDD and PCDF
congeners are plotted separately in Figures 7 to 23. These plots provide the
results for the individual sample analyses, a line defining the results of a
least squares regression analysis, and boundaries that depict the confidence
limits for the range of spiked concentrations. The regression lines were obtained by the method of least squares using the sample measurements at the
three spiking levels and the unspiked level.
Two types of upper and lower 95% confidence limits or bounds were
calculated for the least square regressions of measured (found) concentrations
versus spiked levels. The first set of confidence limits (defined by the
inner pair of curves closest to the regression line) is the 95% confidence
bounds for the regression line. These bounds are interpreted as follows:
The true regression line (as would be determined if the experiment were repeated a countless number of times at the same spiked levels) lies within
these confidence limits unless the analytical results are sufficiently unusual
to be among those expected to occur less than 5% of the time.
The second set of confidence bounds, depicted by the outer pair of
lines, constitutes the 95% confidence limits for the result of a single analysis at a particular spiking level. The interpretation is as follows: the
result (reported value) of a single analysis of a sample spiked at a given
level can be predicted to fall between these 95% confidence bounds unless the
analytical result is among those sufficiently unusual to be expected less than
5% of the time.
23

�Table 10. Spiked Versus Measured Concentrations of 2,3,7,8-TCDF and 2,3,7,8-TCDD

in Homogenized Human Adipose Lipid Samples
2,3,7,8-TCDF
spike level

2,3,7,8-TCDF
concentration

(pg/g)

(pg/g)

13

C12-TCDF

absolute
recovery ( )
%

13

2,3,7,8-TCDD
spike level

2,3,7,8-TCDD
concentration

(pg/g)

(pg/g)

C12-TCDD
absolute
recovery (%)

(.)
41a
a
(.)
41a
(.)
40
(.)
41
0.1
1.8

59
63
59
60.3
2.3
3.8

0
0
0

10.7
11.4
13.1
11.7
1.2
10.5

53
52
46
50.3
3.8
7.5

10
10
10
10

14.3
14.8
13.6
13.8
14.1
0.5
3.9

61
67
71
78
69.3
7.1
10.3

10
10
10
10

23.4
22.8
24.7
22.5
23.3
1.0
4.1

53
53
53
62
55.3
4.5
8.1

25
25
25
25

30.8
30.8
30.7
28.7
30.2
1.1
3.5

59
75
62
72
67.0
7.7
11.5

25
25
25
25

40.8
40.6
40.3
38.3
40.0
1.2
2.9

48
53
51
60
53.0
5.1
9.6

50
50
50

57.7
59.4
55.8
57.6
1.8
3.1

64
48
58
56.7
8.1
14.3

50
50
50

65.8
72.1
67.6
68.5
3.3
4.8

55
43
48
48.7
6.0
12.4

0
0
0
Mean
STD
RSD (%)

ro

Mean
STD
RSD (%)

ND
ND
ND
ND

-pi

Mean
STD
RSD ( )
%

Mean
STD
RSD ( )
%

ND = not detected. Value in parentheses is the estimated limit of detection. A response of greater than
10 times signal-to-noise was noted for both characteristic ions (m/z 304 and 306) at the appropriate
retention time for 2,3,7,8-TCDF. However, the ion ratio was considerably greater than the acceptable
range of 0.61 to 0.90.

�Table 11. Spiked Versus Measured Concentrations of 1,2,3,7,8-PeCDF, 2,3,4,7,8-PeCDF, and 1,2,3,7,8-PeCDD
In Homogenized Human Adipose Tissue Samples

1.2,3,7,8-PeCDF
spike level

(pg/g)
0
0
0

10
10
10
10
Mean
STD
RSO ( )
%

2,3,4,7,8-PeCDF
concentration

(pg/g)

(pg/g)

0
0
0

20.8
21.6
19.0

75
76
80

20.5
1.3
6.5

77.0
2.6
3.4

12.2
11.5
11.9
11.4

10
10
10
10

Mean
STO
RSO (X)

29.2
30.1
28.5
25.5

Mean
STD
RSD ( )
%
ND = not detected.

51.3
55.9
55.5
54.2
2.5
4.7

. 90
63
84
75

50
50
50

54.9
48.5
41.7
48.2

62
81
87
84

64
74
70

69.8
6.1
8.8

69.3
5.0
7.3

The value in parentheses is the estimated limit of detection.

1,2,3,7,8-PeCDD
concentration

»3C,2-PeCDO
absolute
recovery ( )
%

(pg/g)

(pg/g)

0
0
0

20.2
19.9
18.1

51
54
57

19.4
1.1
5.7

54.0
3.0
5.6

32.1
37.6
30.8
30.4

60
57
55
62

30.2
1.9
6.3

58.5
3.1
5.3

48.0
46.1
49.3
43.5

55
60
57
64

46.7
2.5
5.4

59.0
3.9
6.6

69.7
72.2
72.8

58
54
56

71.6
1.6
2.3

56.0
2.0
3.6

10
10
10
10

78.5
11.3
14.4

74.6
62.9
71.9

1.2,3,7,8-PeCDD
spike level

78.0
11.7
15.1

48.4
5.4
11.1

25
25
25
25

28.3
2.0
7.0
50
50
50

27.6
37.0
28.7
36.3

C12-PeCOF
absolute
recovery ( )
%

32.4
4.9
15.2

11.8
0.4
3.1
25
25
25
25

CJ1

NO ( . )
11"
NO ( . )
08
NO (0.8)

13

2,3,4,7,8-PeCDF
spike level

ND ( . )
09
0.2
21.6

Mean
STD
RSO ( )
%

ro

1,2,3,7,8-PeCDF
concentration
(P9/g)

25
25
25
25

50
50
50

�Table 12. Spiked Versus Measured Concentrations of 1,2,3,4,7,8-; 1,2,3,6,7,8-; 2,3,4,6,7,8-; and 1,2,3,7,8,9-HxCDF
in Homogenized Human Adipose Lipld Matrix
1,2,3,4,7,8HxCOF
spike level

(pg/g)
0
0
0

Mean
STO

25
25
25
25

Mean
STO
RSD ( )
%

22.0
22.1
22.4

(pg/g)
0
0
0

46.7
52.0
48.8
49.0

Mean
STD
RSD (X)

125
125
125

90.2
89.1
90.3
90.7

25
25
25
25

156.3
0.9
0.6

(pg/g)
12.3
12.4
12.7

2.3,4.6,7,8HxCDF
spike level

(pg/g)
0
0
0

36.6
38.6
40.8
39.8

62.5
62.5
62.5
62.5

83.7
80.5
79.6
76.0

25
25
25
25

151.0
157.7
149.1

(pg/g)
4.9
4.2
4.2

1,2.3,7,8,9HxCOF
spike level

(pg/g)
0
0
0

32.3
33.6
32.0
32.5

62.5
62.5
62.5
62.5

74.7
75.5
74.2
71.1

25
25
25
25

152.6
4.5
2.9

HO = not detected. The value in parentheses reflects the estimated limit of detection.

141.9
141.6
151.0
144.9
5.3
3.7

(pg/g)

a

13

Ct2-HxCDF
absolute
recovery

()
«

NO ( . )
05
NO ( . )
07
NO (0.9)

55
57
52

55.7
2.5
4.6

34.8
28.5
30.9
29.2
30.9
2.8
• 9.1

59
57
60
67

60.8
4.3
7.2

125
125
125

82.7
89.4
82.2
76.3

60
63
63
70

82.7
5.4
6.5

62.5
62.5
62.5
62.5

73.9
2.0
2.6
125
125
125

1,2,3,7.8,9HxCOF
concentration

NO ( . )
07
0.2
25.3

32.6
0.7
2.1

79.9
3.2
3.9
125
125
125

2,3,4,6,7,8HxCDF
concentration

4.4
0.4
8.9

39.0
1.8
4.7

90.1
0.7
0.7
157.2
155.4
156.4

1,2,3,6,7,8HxCDF
concentration

12.4
0.2
1.7

49.1
2.2
4.4
62.5
62.5
62.5
62.5

Mean
STD
RSD (X)

(pg/g)

1,2,3,6,7.8HxCDF
spike level

22.2
0.2
1.1

RSD (X)

ro

1,2,3.4,7,8HxCDF
concentration

64.0
4.2
6.6

143.0
144.1
163.4

57
54
57

150.1
11.4
7.6

56.0
1.7
3.1

�in Homogenized Human Adipose Lipid Samples
1,2,3,4,7,8-HxCDD
spike level
(pg/9)

0
0
0

25
25
25
25

(pg/g)
0
0
0

4.
78
52.0
53.7
52.7

62.5
62.5
62.5
62.5
Mean
STO
RSD (X)

8.
29
96.7
90.3
81.9

25
25
25
25

141.1
150.8
146.0
145.9
4.9
3.3

(pg/g)
157.0
162.0
154.0

1,2,3,7,8,9-HxCDD
spike level

(pg/g)
0
0
0

184.0
165.0
198.0
193.0

62.5
62.5
62.5
62.5

220.0
239.0
220.0
220.0

280
8.
299.0
266.0
284.3
16.8
5.9

(pg/g)

13

Ct2-HxCDD
absolute
recovery (X)

19.1
26.0
24.7

58
60
58

58.7
1.2
2.0

63.5
46.1
40.8
57.3

65
61
65
70

51.9
10.4
20.0

25
25
25
25

65.3
3.7
5.6

125
125
125

114.0
99.9
101.2
107.4

64
66
66
77

105.6
6.5
6.1

62.5
62.5
62.5
62.5

224.8
9.5
4.2
125
125
125

1,2,3,7,8,9-HxCDD
concentration

23.2
3.7
15.8

185.0
1' 5
4.
7.9

8.
79
7.0
7.9
125
125
125

1.2,3,6,7,8-HxCDD
concentration

157.7
4.0
2.6

51.6
2.6
5.1

Mean
STD
RSD (X)

Mean
STD
RSD (X)

21.6
22.7
20.3

1,2,3,6,7,8-HxCDD
spike level

21.5
1.2
5.5

Mean
STD
RSD (X)

ro

1.2,3,4.7,8-HxCDD
concentration
(pg/9)

68.3
5.9
8.7

141.3
152.7
189.4

62
57
61

161.1
.25.2
15.6

60.0
2.6
4.4

�Table 14. Spiked Versus Measured Concentrations of 1,2,3,4,6,7,8-HpCDF, 1,2,3,4,7.8,9-HpCOF, and 1,2,3,4,6,7,8-HpCOO
in Homogenized Hunan Adipose Lipid Samples

1 ?,3,4,6,7,8-HpCDF
spike level
(99
P/)

0
0
0
Mean
STD
RSD ( )
%

(pg/g)
30.6
27.3
28.6

Mean
STD
RSO (X)

(pg/g)
0
0
0

48.6
48.6
51.0
56.3

Mean
STD
RSD ( )
%

86.3
85.7
80.9
83.4

25
25
25
25

154.5
157.3
154.4
155.4
1.6
1.0

(pg/g)

NO ( . )
13*
ND ( . )a
11*
HD ( . )
10

1,2,3,4,6,7,8-HpCDD
spike level

26
23
23
25

62.5
62.5
62.5
62.5

60
60
59
58

119
126
121

122.4
3.7
3.0

ND = not detected. The value in parentheses is the estimated limit of detection.

13

C,z-HpCDD
absolute
recovery ( )
%

(pa/g)

0
0
0

214.7
210.8
215.5

71
74
69

213.7
2.5
1.2

71.3
2.5
3.5

214.7
239.0
243.9
248.5

83
75
76
78

243.3
40
.
1.7

78.0
3.6
4.6

281.5
288.1
269.9
274.9

77
84
90
99

278.6
8.0
2.9

87.5
9.3
10.7

353.2
355.4
343.7

62
61
69

350.8
6.2
1.8

64
4.4
6.8

25
25
25
25

62.5
62.5
62.5
62.5

59.0
0.8
1.3
125
125
125

1,2,3,4.6,7,8-HpCDD
concentration

(pg/g)

24.1
1.4
5.7

84.1
2.5
2.9
125
125
125

1,2,3,4,7,8,9-HpCDF
concentration

ND ( . )
lla
0.2
13

51.1
3.6
7.0
62.5
62.5
62.5
62.5

a

1,2,3,4,7,8,9-HpCDF
spike level

28.9
1.6
5.7
25
25
25
25

ro
CO

1,2,3,4,6,7,8-HpCDF
concentration

125
125
125

�Table 15. Spiked Versus Measured Concentrations of OCDF and OCDD
in Homogenized Human Adipose Lipid Samples
OCDF
spike level

(pg/g)
0
0
0

Mean
STD
RSD ( )
%

50
50
50
50
Mean
STD
RSD ( )
%

125
125
125
125
Mean
STD
RSD ( )
%

250
250
250
Mean
STD
RSD ( )
%

OCDF
concentration

(pg/g)
4.9
2.3
2.6

(pg/g)

(pg/g)

0
0
0

804
833
781

91
88
94

806.1
26.1
3.2

91.0
3.0
3.3

3.2
1.4
43.1

44.2
45.0
45.9
49.6

860.4
11.4
1.3

125
125
125
125

932
934
944
907

110.7
2.2
2.0

227.8
231.0
228.6

OCDD
concentration

849
856
876
860

50
50
50
50

46.2
2.4
5.2

111.1
107.8
110.7
113.1

13

C12-OCDD
abolute recovery
()
%

OCDD
spike level

929.1
15.7
1.7

250
250
250

100
87
91
91

92.3
5.5
6.0
90
96
102
104

98.0
6.3
6.5

1,080
1,140
1,070
1,096
34.7
3.2

229.1
1.7
0.7

29

69
67
74

70.0
3.6
5.2

�Umplked Hutmn Adipo» Tillue
1.
2.
3.
.
.
.
.
.
.
t .

2.3.7.8-ICOf
'3C|J-2.3.7.»-FCnf
"CI2-I.J.3.4-TCDO
7.3.7.J-FCOD
"CI2-2.3.7.MCDD
1,2.], 7,1.F.CDF
"ClJ-1.2 3.7,1
-P.CDF
2.3,4. 7.».
FrCDF
l,2,3.7,t-NCOD
'3C|}&gt;l.2.3,7.a-r«CDD

1 . '3Cn-l.2.3.4,7.«-H.Crif
Df
1 . 1.2.3.6.7

RIC

4. 2.J.4.i.7.e-M.CDr
S. l,2.3.4,7.e-ll&lt;CDD
«. 1,2,3. 6,7. »-H»COD
7. '3Cl2-l.2.3.6.7.t-H.CDD
I. l.!.3.7.B.»-HrCDl&gt;
'. 1,2.3,7,1,9-HiCDF
20. 1, 2,3.4. *.7.»-HpCDF
21. l,2,3,4.«.7.«-HpCDI&gt;
'K. I3CI2-1. 2.3.4. 4.7,1-HpCOD
23. 37ci4.|.2,3,4(«,7,«.HpCDO

,24
"

25. OCOD
26. "CI2-OCOO
27. OCDF

i

21.:2,23

1

14.17
1 2

7

4,5

\{

li

9, 10

I
i r-.fl

880

IBM

IS
12

18 19

1488

1288

20
1

2888

1688

SCAN

Calibration Standard

11,12

1,2

P.IC
15,14,17

6,7

19

21,22,23

9.10

1888

1288

1488

1888

1988

2888 SCAN

Figure 1. Comparison of the HRGC/MS-SIM reconstructed ion chromatogram(RIC)
from the analysis of unspiked homogenized human adipose tissue
matrix and a calibration standard for PCDDs and PCDFs.

30

�Uraplk.d Human Adipou

384.

Spiked Human AdipoM
|2,3.7.8-TCDF

384

350

1888

last

1188

1158

1200

1290

SCAN

Umpilnd Human Adipax

r '3C|2-lCDF

/-2.3,7,8-ICDD

AJL
lee.eSpikwi Human Ad!po»

320 .

I3C 12-2.3,7.8-ICDF-i

-

A

A

me

y-2.3,7,8-TCDO

A

UN

lisa

i2w

1230

sew

Figure 2. Example of the TCDF (m/z 304) and TCDD (m/z 320) HRGC/MS-SIM
elution profiles in unspiked and spiked human adipose.

31

�Unpllwd Hunan AdlpoM
2.3,4,7.8-PeCDF

1.2,3.7,8-f.CDF

\

Spilwd Hunan Adlpou
2.3.4.7,8-P.CDF
1.2.3,7,8-PeCDF

1

I'"'1 ' ' '"I '
1859
nee

USe

1288

12S8

1308

1358

1488

SCAN

1458

SCAN

Uiapikld Hunan Adlpoi.

354 .

.2,3.7,8-P«COO

Spiked Human AdipoM

l3C|2-l,2.3.7.8-PeCOF

334.

I.2.3.7.8-P.COD

USB

1288

USB

1388

1310

1468

Figure 3. Example of the PeCDF (m/z 338) and PeCDD (m/z 354) HRGC/MS-SIM
elution profiles in unspiked and spiked human adipose.

32

�Unipikod Human Adipose

|l,2.3,.4.7,8-HxCDF

ll.2.3.6,7,8-HxCDF
374 .

.8-H»CDF
1

' i I

''

Spik.d Human Adipou
1.2.3,4,7,8-HxCDF | 11.2.3.6.7.8-HxCDF
[2.3,4,4.7.8-.
\H»CDF

374 .
1.2.3,7,8,9-HxCDF

1343
1258

1398

1983

1358

H93
1480

J498
USB

I \.

ISM

1.556
1550

1609

SCAN

Uraplked Human Adipose

1.2,3,6,7,8-HxCDD

1,2,3.4,7.8-HxCDD-

339 .

13C]2-l,2,3.4.7,8-HxCDF

A

A

1.2.3,7,8,9-H.CDD

Spik.d Human Adipou

1,2.3.6,7.8-HxCDD

399 .

1.2.3,4.7,8-HxCDD
1.2.3.7,8.9-HxCDD
l3

C|2-l.2,3,4,7,8-HxCDF|l

1
1358

1488

1438

1589

1559

1689

1658

SCAN

Figure 4. Example of the HxCDF (m/z 374) and HxCDD (m/z 390) HRGC/MS-SIM
elution profiles in unspiked and spiked human adipose.

33

�Urapilwd Human AdlpaM
11,2,3.4.6,7.8-HpCDF

498.

Spllud Human Adipon
1.2,3,4.6.7,8-HpCDF

1,2,3,4,7,8,9-HpCDF

1458

15B8

1556

1669

1658

1766

1758

1809

SCAN

Umplk.d Human Adlpou
l,2.3.4.6,7.B-HpCDD
424 .

Spilwd Human Adipou

1.2,3,4.6,7,8-HpCDD
424.

•I

1586

1559

1686

'

' "&gt;

'!

'•"

1658

I

1706

•

'

' I

1730

"I"'

1806

I1

1838

SCAN

Figure 5. Example of the HpCDF (m/z 408) and HpCDD (m/z 424) HRGC/MS-SIM
elution profiles in unspiked and spiked human adipose.

34

�Urapilw) Hunan Adtpou

442.

Spiked Human Mlpow
OCDF
442 .

'3C|2-OCDD|

A)

me

(798

teee

test

ts«e

1950

2eee SCAN

isee

ISM

zeea sow

Umplk.d Hunan Adlpon

lOCDD
438 .

Spilwd Hunan Adipoj.

lOCDD

4S8 .

1766

ITM

teee

IBM

Figure 6. Examples of the OCDF (m/z 442) and OCDD (m/z 458) HRGC/MS-SIM
elution profiles in unspiked and spiked human adipose.

35

�80

70 -

Regression Line95% Confidence Limits
for Regression Line

60 -

d
0

50 -

d
CO

en

&lt;D
0
d
0

u

30 -

•a

• 95 % Confide nee Li mi rs
for Individual Anafyses

d
10

0
0

10

I
30

30

I
40

Spiked Concentration (pg/g)
lipid sample meas.
Figure 7. Measured concentrations versus concentrations of 2,3,7,8-TCDD
spiked into the homogenized human adipose lipid matrix.

50

�80

Regression Line

70

95% Confidence Limits
for Regression Line

60 -

d
0

50

d
0
0
CO

&amp;
0

o
S3

d
3
o

30

'95% Confidence
for individual Analyses

10 -

"T ~

0

10

20

D

30

i
40

Spiked Concentration (pg/'g)
lipid sample meas.

Figure 8. Measured concentrations versus concentrations of 1,2,3,7,8-PeCDD
spiked into the homogenized human adipose lipid matrix.

50

�160
150
Regression Line'

140
130

95% Confidence Limits
for Regression Line

W

a

Vx'

120 110 100 90 80 -

co

CO

G
i3
0

o
•a

70 60 50 •95% Confidence Limits
for Individual Analyses

40 30 30 -t
10 -

0

20

40

n

60

80

100

Spiked Concentration (pg/g)
lipid sample meas.

Figure 9. Measured concentrations versus concentrations of 1,2,3,4,7,8-HxCDD
spiked into the homogenized human adipose lipid matrix.

120

�Regression Line

\

95% Confidence Limits
for Regression Line

v.,/

d

0

0

co

d
o
o

•a
d
^

95% Confidence Limits
for Individual Analyses

0

60

0

n

80

100

Spiked Concentration (pg/g)
lipid sample meas.

Figure 10. Measured concentrations versus concentrations of 1,2,3,6,7,8-HxCDD
spiked into the homogenized human adipose lipid matrix.

120

�200 ~r

a
d
o
&lt;sJ
I,
4&gt;

0

d
0

u
•d
d
3
o

190 180 170 160
150
140 H
130 130 110 H
100 90 H
80 70
60 50 40
30 ~
20 4
10 0
-10 0

Regression Line
95% Confidence Li mil's •
for Regression Line

95% Confidence Limits
for Individual Analyses

'"I"

20

40

D
Figure 11.

"T

60

80

100

Spiked Concentration (pg/'g)
lipid sample meas.

Measured concentrations versus concentrations of 1,2,3,7,8,9-HxCDD
spiked into the homogenized human adipose lipid matrix.

120

�370

Regression Line

/•""N

W
&lt;0!

a

95 % Confidence Limits
for Regression Line

v-&gt;

d
0

•H
+»

flj

d
a)
o

d
o
o
-d
d
95% Confidence Limits
for Individual Analyses

200 0

100

20

n

Spiked Concentration (pg/g)
lipid sample meas.

Figure 12. Measured concentrations versus concentrations of 1,2,3,4,6,7,8-HpCDD
spiked into the homogenized human adipose lipid matrix.

120

�1.19
Regression Line-

1.1
95% Confidence Limitsfor Regression Line

1.05 -

s~

1-

d

0.95 -

0 a
rf

&amp; :;
o o
ro

o
O
•0
•95% Confidence Limits
for individual Analyses

0.75 0.7 -

0

r-

j

r_

40

80

n

j

j
120

__ r

j
160

300

Spiked Concentration (pg/g)
lipid sample meas.

Figure 13. Measured concentrations versus concentrations of OCDD spiked
into the homogenized human adipose lipid matrix.

240

�60

Wi
\
fcfi

Regression Line-

50 -

95% Confidence^ Limits
for Regression Line

a
0

•H
•P

30 0

co

ti
o
o

20 -

•0

•95% Confide nee Li mits
for Individual Analyses

d
10

0
0

i
10

I
20

30

Spiked Concentration (pg/g)
lipid sample meas.
Figure 14. Measured concentrations versus concentrations of 2,3,7,8-TCDF
spiked into the homogenized human adipose lipid matrix.

50

�60
Regression Line-

50 U

95% Confidence Limitsfor Regression Line

40 -

d
o
30 -

o

d
o
o
•d

• 95 % Confidence Limits
for Individual Analyses

10 -

-10

0

I
10

T

20

30

i
40

Spiked Concentration (pg/g)
D
lipid sample meas.
Figure 15.

Measured concentrations versus concentrations of 1,2,3,7,8-PeCDF
spiked into the homogenized human adipose lipid matrix.

50

�90
Regression Line-

80 -

W)

ft

d
0

95%JTonfidence Limitsfor Regression Line

70 -

60 -

50
&lt;D
0

d
0

o

40 -

•a
30 95% Confidence Limits
for Individual Analyses

20
10

I

0

10

I
20

i
30

i
40

Spiked Concentration (pg/g)
D
lipid sample meas.
Figure 16. Measured concentrations versus concentrations of 2,3,4,7,8-PeCDF
spiked into the homogenized human adipose lipid matrix.

50

�160 ~r

150 r~\

\

140 130 -

A

110 -

•p

100 -

t

CTl

95% Confidence Limitsfor Regression Line

130 -

d
o

•pa

Regression Line-

90 -

d
0
0
d
0

80 70 -

u

60 -

d

50 -

0

•95% Confidence Limits
for Individual Analyses

40 30 20J
10 -

"T

0

Figure 17.

20

40

60

80

100

Spiked Concentration (pgXg)
n
lipid sample meas.
Measured concentrations versus concentrations of 1,2,3,4,7,8-HxCDF
spiked into the homogenized human adipose lipid matrix.

120

�__

160 150 140 Regression Line-

130 0.

d

0
rf

130 95% Confidence Limitsfor Regression Line

110 100 90 80 -

0

ti
0
u
Tl
d
3
0

70 60 50 95 % Confidence Limits
for Individual Analyses

40
30

20 ^
10

0 0

i
40

i
20

o
Figure 18.

i
60

80

100

Spiked Concentration (pg/g)
lipid sample meas.

Measured concentrations versus concentrations of 1,2,3,6,7,8-HxCDF
spiked into the homogenized human adipose lipid matrix.

130

�160
150

W

0.

vx
{3
0
&gt;r4

+J

at

140
130
120

Regression Line95% Confidence Limitsfor Regression Line

110
100
90
80
70

0
CO

d

60

o

50

0

95% Confidence Limits
for Individual Analyses

30
0

20
10
0
10
0

20

40

60

80

100

Spiked Concentration (pg/g)
n
lipid sample meas.
Figure 19.

Measured concentrations versus concentrations of 2,3,4,6,7,8-HxCDF
spiked into the homogenized human adipose lipid matrix.

120

�bi'
P,
s*&gt;

d
o

IO

d
fi)
0
d
0

u
•d

170
160
150
140
130
120
110
100
90

Regression Line-

95% Confidence LimiHfor Regression Line

80
70
60

50
40
30
20
10
0
-10
-20

•95% Confidence Limits
for Individual Analyses

0

20

40

n
Figure 20.

60

80

100

Spiked Concentration (pg/g)
lipid sample ineas.

Measured concentrations versus concentrations of 1,2,3,7,8,9-HxCDF
spiked into the homogenized human adipose lipid matrix.

120

�\
95

for Regression Line

ti
0

0
0
01

o

d
0

95% Confidence Limits
for Individual Analyses

u
•a
d

-10

80

0

D

100

Spiked Concentration (pg/g)
lipid sample meas.

Figure 21. Measured concentrations versus concentrations of 1,2,3,4,7,8,9-HpCDF
spiked into the homogenized human adipose lipid matrix.

120

�170
160 150 140
W
P.

d
0

Regression Line-

130 95% Confidence Limitsfor Regression Line

130 110 100 -

d
0)
0
d
0

u
•d

d
3
0

90 80 70 -

60 -

_
_
_
for Individual Analyses

50 40 -

fcl

30
20 H
10 0

20

40

D
Figure 22.

60

1
80

100

Spiked Concentration (pg/g)
lipid sample meas.

Measured concentrations versus concentrations of 1,2,3,4,6,7,8-HpCDF
spiked into the homogenized human adipose lipid matrix.

120

�240
220 200
Regression Line

180 H

95% Confidence Limits
for Regression Line

160

d
o

140
120 H

d
0

100 -

0

Ol
IN3

d
0
u
-a
d

95% Confidence Limits
fpr Individual Analyses

80
60

-20 0

—,
80

n
Figure 23.

120

160

200

Spiked Concentration (pg/g)
lipid sample meas.

Measured concentrations versus concentrations of OCDF spiked
into the homogenized human adipose lipid matrix.

240

�The slopes of the calculated regression lines from the data points
in each of the 14 analyses can be used as an indication of the accuracy of
the analytical method for the 17 target analytes. Figure 24 is a plot of the
slope of regression lines versus the 17 individual compounds. Table 16 provides a key to specific compounds associated with a number on the x-axis of
this plot. The plot presents the estimated slope from each least squares regression line as well as the upper and lower 95% confidence limits for the
slope. The slope of the regression line can be interpreted as a measure of
accuracy with a value of 1.00 equivalent to 100% agreement of the measured
concentration with the theoretical values (background plus spike level). The
plot of the 95% confidence limits presents some confirmation on the precision
of measurements across the four spike levels. These confidence bounds can
also be used to determine whether the accuracy of the measurements (slope of
regression line) is significantly different from 100% (or 1.00). If the vertical line connecting the lower and upper 95% confidence limits intersects
with the horizontal line at 1, then the accuracy of the method (as determined
from the regression line) is not significantly different from 100% (slope =
1.00). The results plotted in Figure 24 demonstrate that the method accuracies for 7 of the 17 analytes are not significantly different from 100%.
On the other hand, if the upper and lower confidence limits are both
greater than or both less than 1.00, then the accuracy of the method is significantly different from 100%. The data presented graphically in Figure 24
indicate that some positive bias (greater than 100%) is associated with the
method accuracies for 9 of the 17 analytes while the measurements for a single
analyte (OCDF) result in a slightly negative (less than 100%) bias.
Table 16 provides a key to the compound identification in Figure 24
and tabulates the slope of the regression lines and the upper and lower 95%
confidence limits for each of the 2,3,7,8-substituted PCDD and PCDF analytes.
As noted from Table 16, method accuracy (as defined by the regression line
slope) ranges from 90% for OCDF up to 121% for 1,2,3,7,8,9-HxCDF. The accuracies for all other measurements fall within a range of 97 to 115% with the
exception of the 1,2,3,7,8,9-HxCDF (compound no. 9). The overall method accuracies meet the initial accuracy objective of 50-115% identified in the
project quality assurance program plan. However, the predicted accuracy results for individual analysis as defined by the 95% upper confidence limits
indicate that this range should be adjusted to 50-130%.
The bias in the accuracy of the measurements may be a result of
slight differences in the concentration calibration standards and the internal
quantisation standard and native PCDD and PCDF spiking solutions. As a preliminary check on these differences, solutions of the low level and of the
high level native spike combined with the internal quantisation standards were
analyzed. The results of these analyses are provided in Table 17. Accuracy
was calculated as measured/spiked x 100.
The results of these analyses suggest that bias observed in overall
method accuracy is attributed to the differences in the spiking solutions versus the calibration standards. For instance, the four HxCDF isomers demonstrated a consistent positive bias to method accuracy based on the least squares
regression analysis. The analysis of the spiking solutions, submitted as samples, also indicates a definite positive bias for the same four HxCDF isomers.
53

�ACCURACY ESTIMATES
1.4

1.3 &lt;D

o

1.2 H

V)

Oi

£

II

1.1 t)

+

n

o
0)

J!

i

09 .

OJ

T—r

_j

j

j

r—r

j..

-T

r

#01 #Q2#03#04#05#06#Q7#08#09#10#11#12#13#14#15#16# J 7
a slope estSmote

Compound Number
-tlower 95% CL

o

upp«r 35% GL

Figure 24. Method accuracy estimates as determined from the slopes of
the least squares regression lines for the 17 target PCDD and
PCDF analytes. Refer to Table 16 for the key to compound number.

54

�Table 16. Regression Line Slopes with 95% Confidence Limits
Compound
no.

Compound

01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17

2,3,7,8-TCDF
2,3,7,8-TCDD
1,2,3,7,8-PeCDF
2,3,4,7,8-PeCDF
1,2,3,7,8-PeCDD
1,2,3,4,7,8-HxCDF
1,2,3,6,7,8-HxCDF
2,3,4,6,7,8-HxCDF
1,2,3,7,8,9-HxCDF
1,2,3,4,7,8-HxCDD
1,2,3,6,7,8-HxCDD
1,2,3,7,8,8-HxCDD
1,2,3,4,6,7,8-HpCDF
1,2,3,4,7,8,9-HpCDF
1,2,3,4,6,7,8-HpCDD
OCDF
OCDD

Significantly Lower 95% Upper 95%
confidence confidence
different
Slope from 1.00?
limit
limit
1.08
1.13
1.07
0.98
1.04
1.07
1.12
1.12
1.21
0.98
1.01
1.12
1.01
0.97
1.08
0.90
1.15

yes
yes
yes
no
no
yes
yes
yes
yes
no
no
no
no
no
yes
yes
yes

55

1.04
1.08
1.02
0.82
0.98
1.06
1.09
1.09
1.12
0.92
0.86
0.94
0.95
0.95
1.01
0.88
1.00

1.11
1.19
1.12
1.13
1,11
1.09
1.16
1.15
1.29
1.05
1.16
1.30
1.07
1.00
1.16
0.92
1.30

�Table 17. Results of the Analysis of the Low and High Level Native Spike Solutions
Low level spike

Compound

Spi ke
concentration
(pg/uL)

Measured
concentration
(pg/uL)

Accuracy
()
%

High level spike
Spike
Measured
concentration concentration
(pg/ML)
(pg/ML)
50

Accuracy
()
%

2,3,7,8-TCDF
2,3,7,8-TCDD

13
12

130
120

50

54
57

108
114

1,2,3,7,8-PeCDF
2,3,4,7,8-PeCDF
1,2,3,7,8-PeCDD

en

10
10
10
10
10

11
10
12

110
100
120

50
50
50

52
49
53

104
98
106

1,2,3,4,7,8-HxCDF
1,2,3,6,7,8-HxCDF
2,3,4,6,7,8-HxCDF
1,2,3,7,8,9-HxCDF
1,2,3,4,7,8-HxCDD
1,2,3,6,7,8-HxCDD
1,2,3,7,8,9-HxCDD

25
25
25
25
25
25
25

27
32
35
40
27
24
39

108
128
140
160
108
96
156

125
125
125
125
125
125
125

134
137
152
185
123
132
148

107
110
122
148
98
106
118

1,2,3,4,6,7,8-HpCDF
1,2,3,4,7,8,9-HpCDF
1,2,3,4,6,7,8-HpCDD

25
25
25

22
25
26

88
100
104

125
125
125

116
121
130

93
97
104

OCDF
OCDD

50
50

44
48

88
96

250
250

247
250

99
100

�Similar trends are noted for other compounds in Table 17 compared to the data
presented in Figure 24 and Table 16.
The limited number of analyses of the spiking solutions does not
provide an adequate comparison with the sample data to confirm the bias.
However, it is recommended that at least triplicate measurements of the spiking solutions at each fortification level should be analyzed at the outset of
the actual NHATS sample analysis program. This will be necessary to account
for any biases that will be observed from the determination of PCDD and PCDF
residue levels in spiked QC samples. It should be noted that additional
homogenized spiked samples will be prepared prior to initiation of the NHATS
sample analyses.
1. Recovery of Internal Quantitation Standards
The absolute recoveries for the carbon-13 labeled internal quantitation standards were determined for each sample by comparing the responses
to the internal quantisation standard, 13C12-1,2,3,4-TCDD. The 13
average recoveries of the compounds in Tables 10 to 15 range from 52.1% for C12-2,3,7,8TCDD up to 88.9% for 13C12-OCDD. The results for the absolute recoveries compared to the overall method accuracy for each compound indicate the importance
of the internal standard quantisation technique for analysis of the PCDDs and
PCDFs in human adipose.
2. Estimation of Background Levels of PCDDs and PCDFs
The estimated background levels of the various PCDD and PCDF congeners were determined as the intercept obtained from the least squares linear
regression analyses. Table 18 summarizes the estimated background levels
along with their upper and lower 95% confidence limits. These background
levels and confidence limits can be viewed as the intersections of the regression line and its upper and lower 95% confidence bounds, respectively, with
the y-axis (measured or found concentration). These values will be used as
the initial data points for developing control charts of the unspiked lipid
matrix which will be analyzed with each batch of samples throughout the EPA/VA
study.
3. Day-to-Day HRGC/MS Analysis Precision
In addition to the analysis of the replicate spiked samples, four
extracts were analyzed by HRGC/MS on two different dates. The results of the
duplicate HRGC/MS analyses of these four samples for the 17 target compounds
are presented in Tables 19 to 21. Concentration values from the second analysis date were included in the statistical analysis of data presented earlier
in this section.

57

�Table 18. Background Level Estimates with 95% Confidence Limits

Compound
no.
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17

Compound
2,3,7,8-TCDF
2,3,7,8-TCDD
1,2,3,7,8-PeCDF
2,3,4,7,8-PeCDF
1,2,3,7,8-PeCDD
1,2,3,4,7,8-HxCDF
1,2,3,6,7,8-HxCDF
2,3,4,6,7,8-HxCDF
1,2,3,7,8,9-HxCDF
1,2,3,4,7,8-HxCDD
1,2,3,6,7,8-HxCDD
1,2,3,7,8,9-HxCDD
1,2,3,4,6,7,8HpCDF
1,2,3,4,7,8,9HpCDF
1,2,3,4,6,7,8HpCDD
OCDF
OCDD

Lower 95% Upper 95%
Estimated
Level
background significantly confidence confidence
limit
level
limit
different
from zero?
(pg/g)
(pg/g)
(pg/g)
ND (3.6)a
11.8
ND (1.1)
22.2
19.8
11.2
4.3
ND (2.3)
24.9
159.4
26.5
25.7

yes
yes
no
yes
yes
yes
yes
yes
no
yes
yes
yes
yes

2.7
10.4
-0.2
17.9
18.2
21.3
8.6
2.1
-3.6
20.5
149.3
14.3
21.9

4.5
13.3
2.5
26.4
21.5
23.5
13.7
6.5
8.2
29.3
169.5
38.7
29.6

ND (0.3)

no

-2.1

1.5

214.0

yes

208.9

219.1

ND (1.0)
799.7

no
yes

-1.7
779.4

3.8
820.0

22.4

ND = not detected, The value in parentheses reflects the estimated method
detection limit.

58

�Table 19. Day-to-Day Precision of Analysis of Specific Sample Extracts
for Tetra- and Pentachloro PCDF and PCDD
Spike 2,3,7,8Analysis level
TCDF
date
(pg/g) (pg/g)
4/22/86
4/28/86

0
0

RPD ( )
%b

4/22/86
4/28/86

25

0
0

RPD ( )
%

4/22/86
4/28/86

RPD ( )
%

ND (3.1)
ND ( . )
41
28

0
0

ND (3.3)
ND ( . )
40

1,2,3,7,8PeCDD

1,2,3,7,8PeCDF

(pg/g)

(pg/g)

10
11

ND ( . 4
08)
ND (1.12)

24
21

18
20

14

12

23
22

17
20

5

14

16
19

17
18

(pg/g)

4

29

ND (0.78)
ND (0.75)

10
11

4

13
10
13

ND (0.81)
ND (0.75)

(pg/g)

19

RPD ( )
%

4/22/86
4/28/86

ND (3.0)a
ND ( . )
41

2,3,4,7,8PeCDF

2,3,7,8TCDD

10
10

31

8

15

5

12
14

21
23

11
12

26
28

27
19

14

12

13

7

36

a

.ND = not detected. Value in parentheses is the estimated limit of detection.
Relative percent difference. Calculated as the difference of the two values
divided by the mean of the two values times 100%.

59

�Table 20. Day-to-Day Precision of Analysis of Specific Sample Extracts for Hexa- and Heptachloro PCOF and PCDO

4/22/86
42/6
/88

0
0

RPO ( )
Xb

0
0

RPO (%)

4/22/86
4/28/86

0
0

RPD (%)

42/6
/28
4/28/86
RPO (X)

25
25

20
22

16
19

28
31

10

13

20

8

NO ( . 2
03)
ND ( . 4
07)

21
23

150
178

18
26

25
27

79

9

17

38

9

21
20

176
171

18
25

27
29

102

5

3

32

8

116

3

28
32

30
35

43
49

171
181

46
63

46
49

23
25

235
241

13

15

15

6

31

5

12

3

12
12

1

22
22

12
12

5

20
23

12
13

9

10

44
47

36
37

6

1

(pg/g)

1,2,3,4,
7,8,9HpCDF

149
170

21
22

(pg/g)

1.2,3,
6.7,8HxCDD

1.2,3,4,
6,7.8HpCDF

10

(pg/g)

(pg/g)
4.2
4.9
15

4.0
4.2

5
3.9
4.3

1.2,3,
7,8,9HxCDF

1,2,3,
4,7,8HxCDO

1,2,3,
7,8,9HxCDD

1,2,3,
6,7,8HxCOF

1

Analysis
date

4/22/86
4/28/86

2,3,4,
6,7,8HxCOF

1,2,3,
4,7,8HxCDF

6

Spike
level

(pg/g)

NO ( . 3 a
03)
ND ( . 1
05)
43

ND ( . 1
04)
ND ( . 6
08)

(pg/g)

(pg/g)

(pg/g)

(pg/g)

rND = not detected. The value in parentheses is the estimated limit of detection.
Relative percent difference. Calculated as the difference of the two values divided by the mean of the two values times 100%.

(pg/g)

ND ( . 3
08)
NO ( . 6
03)
79

ND ( . 9
10)
ND ( . 4
11)

4
NO ( . 6
10)
ND ( . 8
02)

1,2,3,4,
6,7,8HpCDO

(pg/g)
210
216

3
207
211

2
223
216

�Table 21. Day-to-Day Precision of Analysis of Specific Sample Extracts
for OCDF and OCDD
Analysis
date
4/22/86
4/28/86

OCDF
concentration

OCDD
concentration

(pg/g)

(pg/g)

(pg/g)

0
0

4.9
3.5

811
810

Spike
level

RPD ( )
%a

4/22/86
4/28/86

0
0

2.2
2.3

RPD ( )
%

4/22/86
4/28/86

0
0

1.9
2.6

2
788
784

31

1

43
44

834
848

3

50
50

RPD ( )
%
a

819
836

4

RPD (%)
4/22/86
4/28/86

0

33

2

Relative percent difference. Calculated as the difference of the two
values divided by the mean of the two values times 100%.

61

�VI. QUALITY ASSURANCE/QUALITY CONTROL (QA/QC)
As discussed in the experimental section of this report, the QA/QC
activities included the analysis of a multipoint calibration curve, daily
verification of relative response factors for each analyte, analysis of a
method blank and reagent blanks along with the samples, and determining the
absolute recoveries of each of the internal quantisation standards for every
sample. Each of these QA/QC activities is discussed below.
A. Initial Calibration
At the outset of sample analysis activity, six calibration concentration standards containing each of the target PCDDs and PCDFs at varying
levels and constant concentrations of the internal quantisation and recovery
standards were analyzed in triplicate. The relative response factors (RRF)
for each native compound and internal quantitation standard were determined
for each standard analysis. An average RRF and relative percent standard
deviation (RSD) were determined for each concentration level. The average
RRF values from each of the six concentration calibration standards were then
used to calculate a grand mean RRF value for each compound in the calibration
solution. Table 22 presents a summary of the grand mean RRF values for each
component in the standards. As noted from Table 22, the average RRF values
for native PCDDs and PCDFs generally varied by less than ± 10% (RSD) with the
exception of the pentachloro congeners. These results fall well within the
criteria established in the draft quality assurance program plan which required the variability of RRF values for the tetrachloro homologs to be within
± 20% (RSD) while the RRF criterion on all other compounds was set at ± 30%
(RDS).
The variability of the RRF values for the internal quantisation
standards, on the other hand, was noted to increase with the degree of chlorination. This is a result of the measurement of all internal quantisation
standards versus the single internal 37
recovery standard, 13C12-1,2,3,4-TCDD.
A second internal recovery standard, Cl4-l,2,3,4,6,7,8-HpCDD, was evaluated.
However, problems resulting from contribution of native HpCDD to the characteristic ions of this internal standard resulted in variabilities in the RRF
value up to 50%. Hence, this internal standard was not used for any calculations. It is anticipated that an additional internal recovery standard, such
as 13C12-l,2,3,4,7,8-HxCDD, will improve the variability in the RRF values of
the higher chlorinated internal quantisation standards. This compound will
be incorporated into the method if available.
The sensitivity of the Kratos MS-50TC to the tetra- through octachloro PCDDs and PCDFs was demonstrated through the triplicate analysis of
the low level standard (CS-8, Table 2) that ranged in concentration from
1 pg/uL for the tetra- and pentachloro congeners up to 5 pg/uL for the octachloro congeners. Table 22 provides an indication of the observed signal-tonoise ratio for each of the native PCDD and PCDF congeners. These data demonstrate that the low level standard is well above the instrument detection
limit, which is defined as the amount of a particular compound necessary to
give a signal 2.5 times the background signal to noise for each of the characteristic ions while meeting the qualitative criteria for ion ratios.

62

�Table 22. Relative Response Factors (Grand Means) Determined from
Multipoint Concentration Calibration Standards

Compound

RRFa

1.00
0.80
0.98
1.06
1.33
0.94
0.93
0.86
0.86
1.31
1.44
1.61
2.33
1.89
1.19
1.38
1.04

5.7

1,2,3,7,8-PeCDF
2,3,4,7,8-PeCDF

1,2,3,7,8-PeCDD
1,2,3,4,7,8-HxCDF
1,2,3,6,7,8-HxCDF
2,3,4,6,7,8-HxCDF
1,2,3,7,8,9-HxCDF
1,2,3,4,7,8-HxCDD
1,2,3,6,7,8-HxCDD
1,2,3,7,8,9-HxCDD
1,2,3,4,6,7,8-HpCDD

1,2,3,4,7,8,9-HpCDD
1,2,3,4,6, 7, 8-HpCDD
OCDF
OCDD
13
C12-l,2,3,4-TCDDb'c
13
C -2,3,7,8-TCDF
13 12

1.00
1.98
C -2,3,7,8-TCDD
1.73
13 12
1.36
C12-l,2,3,7,8-PeCDF
13
C12-l,2,3,7,8-PeCDD
0.70
13
C12-l,2,3,4,7,8-HxCDF 1.28
13
C -l,2,3,6,7,8-HxCDD 0.41
13 12
C12-1,2,3,4,6,7,80.33
HpCDD
37
C14-1,2,3,4,6,7,80.12
HpCDD
13
C12-OCDD

0.24

6.2

5.2
10.1
11.3
3.1
2.4
2.7
6.9
4.9
3.0
1.0
4.0
3.6
4.7
3.3

2.5
_

Calibration
range
(pg/MD

12
6.5
11
8.9
5.7
32
30
29
17
13
14
14
35
26
13
31
21
_

RSD ( )
%

2,3,7,8-TCDF
2,3,7,8-TCDD

Signal-to- noise
ratio for low.
level standard

1-100
1-100
1-100
1-100
1-100
2.5-250
2.5-250
2.5-250
2.5-250
2.5-250
2.5-250
2.5-250
2.5-250
2.5-250
2.5-250
5-500
5-500

-

50
50
50
50
50
125
125
125

51.8

-

125

28.0

™

250

7.6
4.7
4.5

7.7
15.8
19.6
25.8

.

-

JIJRRF = grand mean RRF.
characteristic ion for each native PCDD or PCDF congener (Data File
8501D17X02).
Internal recovery standard.

63

�B. Daily Verification of Response Factors
Before proceeding with analysis of samples, the analyst was required
to verify the existing response factor calibration through the analysis of a
calibration standard (CS-7, Table 2). Criteria for proceeding with sample
analysis required that the measured RRF value for 2,3,7,8-TCDD and 2,3,7,8-TCDF
were within ± 20% (and all other congeners within ± 30%) of the mean RRF established from the calibration curve. This standard was also analyzed at the
end of each working day to demonstrate that the calibration had been maintained.
All RRF values were tabulated to generate RRF control charts for each specific
PCDD and PCDF congener.
Figures 25 through 34 are plots (control charts) of the RRF values
established for the 17 individual target analytes. The RRF data are plotted
versus time of analysis. These plots contain 28 individual data points, 18
of which were generated for triplicate analysis of 6 concentration calibration
solutions from initial calibration and 10 analyses of solution CS-7 (Table 2)
injected over the 5 days for which actual samples were analyzed. The upper
and lower boundaries (dashed lines) represent a relative standard deviation
of approximately ± 10% with the exception of the plot for 1,2,3,7,8-PeCDD,
for which the boundaries are plotted as ± 20%.
It should be noted that the actual control limits as specified in
the project QAPP were set at ± 20% for 2,3,7,8-TCDD and 2,3,7,8-TCDF and ± 30%
for all other target analytes. The average RRF values and corresponding standard deviations reported in each of these plots are calculated from the total
28 standard analyses.
C. Blanks
As specified in the quality assurance program plan, a laboratory
method blank was prepared along with the 14 human adipose lipid samples. The
method blank was taken through all procedures as if it were an actual sample,
although no lipid matrix was introduced. The analysis of the method blank
resulted in the data reported for each of the target analytes reported in
Table 23. As noted in Table 23, 1,2,3,4,6,7,8-HpCDD and OCDD were detected
at concentrations equivalent to 4.0 and 30 pg/g (equivalent to a 10-g lipid
sample), respectively. In addition to these compounds, responses that correspond to the elution of two TCDD isomers (1,3,6,8- and 1,3,7,9-) and a PeCDD
(isomer not determined) were detected in the method blank. Further analysis
of individual reagents used for preparation of the samples identified the activated acidic alumina as the source of the artifacts. Acidic alumina that
had been cleaned by Soxhlet extraction but not activated at 190°C was analyzed,
and the artifacts were not detected. This indicates that the artifacts are
generated during activation of acidic alumina at elevated temperatures (190°C).
Similar background problems from the same PCDD 18
congeners have recently been
reported by the Center for Disease Control.17'

64

�(flRBVREF.flKeW/CflMT./REF.flHT.)
1.208

9.337)

¥
i

ST.DEV.9.865
Z ST.OEU.«
S.5S1

X
1.189

Jl

•
.

y
T

if
*

i

•

DATE

"
n

ii

ii y

1

x

3.390

t

i X"
i TI

•If if

'j

v

_

i

«!
X

_

S/

4/23/85

4/13/SS

9.897)
ST.OPJ.8.035
2 ST.OEU.5.932

X
1

9.909

.

1

v

•
?
,
t

|

&lt;! J
1

tl

1

Jl

^X
11
11

n^
1
1

.**

\
J

^
V

1

1J

II
H

1

X

X

9.789

DftTE

5/3/86

Figure 25. Control charts showing response factors by date for 2,3,7,8-TCDF
and 2,3,7,8-TCDD. Dotted lines represent approximately ± 10% of the mean.
65

�F&lt;C13-l/2(3.7/
MKEft/KEF.ARBWAANT./REF.flHT.)
1.268

1.188

_____

9.971)

T
[
x f
r
_ j^_ L.
Tr 1

(
ST.OEU.'
9.835
7.
? ST.OEU.8.739

_ _

\(.
-T

n •
n /£
n v(
ii w
*
*
|
1

'*lC
9.966

_

w

1

*

\L!
7W
^

y X*
-f Tl

x

r

1
w
A

*i

~~Tx
X

8.866

x
9.709
DATE

4/13/86

4/23/86

v'fiKEft/REF.flfi£ft)/&lt;fW.--REF.ft«T.) (AUt
1.469

1.353)
ST.DEU.»
9.113
r. ST.OEU.
18.691

X

1.366

1

1
1
1

1.290

i

i

" a
n S
V

MM

1.668

i^

x

8.369

*r

^

"

1111

&gt;1

-uA

x
'

w

i I

X

/\

^f

x

X

8.789
DATE

3/ 3/86

4/13/86

4/23^5

5/ 3/86

Figure 26. Control charts showing response factors by date for 1,2,3,7,8-PeCDF
and 2,3,4,7,8-PeCDF. Dotted lines represent approximately ± 10% of the mean.
66

�.AHT.) (flUi

1.375)

3.000
ST.OEU.0.233
Z ST.DEU.'
18.8135

¥
i
i
2.889

i
i
i

x

X
DATE

4/13/86

4/23/86

5/ 3/85

Figure 27. Control chart showing response factors by date for 1,2,3,7,8-PeCDD.
Dotted lines represent approximately ± 20% of the mean.

67

�&lt;f*£ft/R£F.f*BV/««T./REF.ftl1T.) (flVi

9.329)

1.188
ST.DEU.»
9.046
2 ST.OEU.»
4.899

it
ii

1.999

ft
II
ii
II

4»

y»

11

' (ft

jj
AL
A

0.309

v
v
1

A^

y
T
v

v
A1

i

t

' ''
!
^v
A

1

X

v
^

-^

9.390

4/ 13/86

MTE

4/23/86

(flREft/REF.fWEft&gt;/&lt;ftWT./ReF.fl«T.) «Wi
1.168
-|

S/ 3/85

8.923)
ST.OEU.0.S48
?. ST.OEU.'
4.348

•

1.808

'

x

1

¥
*

k J
!

v

1.

,

K

v
X

1. f

0.388

If

y
!

j!

X
X

x

x

9.399

DATE

4/13/86

4/23/86

V 3/86

Figure 28. Control charts showing response factors by date for lj2,3,4,7,8-HxCDF
and 1,2,3,6,7,8-HxCDF. Dotted lines represent approximately ± 10% of the mean.
68

�((WEfl/R£F.ftR£rt)/(AnT./REF.ArtT.) (flUi

0.862)

l.VW

ST.DEU."
0.038
7. ST. OP.'.4.429

i
i
i
0.300

? 1
% $

Jf

i*
ii

!*

'

9.899

x

i

0.760
VI 3/86

DOTE

4/23/86

5/3/86

« 3
M U
&lt;ftR£fl/REF.AREA&gt;/«OT./REF.ftMT.) &lt;(Wl
1.299

8.883)
ST.OE«.«
9.982
Z ST.OEV.-

x

9 327

-

1.199

¥

1.999

¥
*

0.308

!

H

!

'

'

r w

'

JJ «
e.309

X

X
1

i

X

¥
'

!

x

x
1

x

X
a. ran

4/23/86

3/ 3/86

Figure 29. Control charts showing response factors by date for 2,3,4,6,7,8-HxCDF
and 1,2,3,7,8,9-HxCDF. Dotted lines represent approximately ± 10% of the mean.
69

�PiCl3-l,2;376,7,^flBSiCHLOR(M)IOXIH
&lt;ARBVR£F.flRe»/&lt;flNT./REF.««r.) ((Wt
1.589

1.394)

ST.OEU.«
9.977
Z ST.DEV.3.310

1.4TO

x
T
1.399
1

i

'
X

w
A

1.299

X
1.199
DATE

4/13/8S

V 3/BS

4/23/85

./REF.AHT.) &lt;W|

1.433)

1.796
ST.DEU.»
9.936
Z ST.OEV.'
6.015

1.680

-Ti

i
HI
ni
in
HI
in
in

1.569

,.

x

1.409

x

« i

X

i

1.399

,_*.-

x
1.299
DATE

4/13/86

4/23/86

S/ 3/86

Figure 30. Control charts showing response factors by date for 1,2,3,4,7,8-HxCDD
and 1,2,3,6,7,8-HxCDD. Dotted lines represent approximately ± 10% of the mean.
70

�1.637)
2.399

s

h

2.299

e
ST.DEU.0.135
Z
? ST.OEU.9.384

2.199

&lt;

)
2.999

1.899

X
1
1

1.799

1
1

V&amp;
sx ^
i

1.S99

X

i

v
"T

i

X
1.48B

WTE

V13/8S

4/23/8S

Figure 31. Control chart showing response factors by date for 1,2,3,7,8,9-HxCDD.
Dotted lines represent approximately ± 10% of the mean.

71

�mmm

&lt;ftREft/REF.AR£ft&gt;/&lt; AHT./R£F.fl«T.) (flUl
2.660

2.228)
«
*
J
i

2.500

ST.DEV."
0.182
2 ST.OEU.8.163

.

k
* xi

2.460

H
a

2.309

*x

• *

»

i

*

2.260

!
x x

;; A

i

•!
x

X

2.160

"

W

A

x

1.309
X

x
OrtTE

4/13/85

4/23/86

S/ 3/86

S:-fa§i^I;3ji^aiBWKirsra««.(fKEA/f£F.AREA&gt;/( WT./REF.filfT.) (flU«
2.160

1.783)
X
i
,1
$

2.669

ii

ST.OEU."
0.169
Z ST.OE1^.9.426

i

1.360

1!

1.3W

!i

!j
!

X'

1.760

x
1.660

j
ii
M

*J

!
•

X

x

1.500

f

x
fb

«•«••»

X

;:

X
I.46A
DATE

V13^S

4/23/SS

Figure 32. Control charts showing response factors by date for 1,2,3,4,6,7,8-HpCDF
and 1,2,3,4,7,8,9-HpCDF. Dotted lines represent approximately ± 10% of the mean.
72

�«*Eft/R£F.ftRB»/&lt;AMT./REF.&lt;*T.) (AUi
1.460

1.175)
ST.OEU.8.071
2 ST.OEU.'
S.043

¥
1.369

_

*• .
.

_

. » .. — —
j

*»

_

M

*

W M

_ t a

«...-,~._VyJ__-.«

iI
•

•H*
K*

M

x

Y

PS

A

• '

'!•
A

« if
I *

X
1.106
-M

•
,

'

'
X

i

x

ii
'

lv

'i
y

t

• * « « . •

'1

i!
'
X|
i

x
.'!-•««,«,.

•
.

X

e.see
DATE

4/13/86

4/23/8S

5/ 3/8S

Figure 33. Control chart showing response factors by date for 1,2,3,4,6,7,8-HpCDD.
Dotted lines represent approximately + 10% of the mean.

73

�0IOXIN
&lt;«R»/R£F.f*EA&gt;/&lt;«1T./P.EF.fl«T.&gt; (AUi

1.238)

1.500

X
'
5fi
it

V
i

i
i
i
i

1.480

w
III

ST.DEV.9.117
* ST.DEW.»
8.378

Jt

I

III

t
«. -

l«Zvv

M
•
«
M

M

-

i

'I
{
X

~

i
:
X

x

4

^.j.i_

_

___________
X

4/23/86

4/ 3/86

DATE

w
AJy

X

1.189

5/3/86

ffiS»K»?«M
1.033)

(AREft/KEF.rtRBWAAHT.v'REF.AMT.) &lt;AUi
1.283
-i

ST.OEU.3.843
Z ST.OEU..
4.181

1.183

i
i

X

X
X

m
m

J\
1.309

,

i

*
^
1

x

'

X

Xx

—1-»— •

^
X

X

X

i
i
i

X

8.300

4/23/86

5/ 3/86

Figure 34. Control charts showing response factors by date for OCDF and OCDD.
Dotted lines represent approximately ± 10% of the mean.
74

�Table 23. Summary of Results from the Analysis
of a Laboratory Method Blank
Concentration3
(pg/g)

Compound
2,3,7,8-TCDD
2,3,7,8-TCDF
1,2,3,7,8-PeCDF
2,3,4,7,8-PeCDF
1,2,3,7,8-PeCDD
1,2,3,4,7,8-HxCOF
1,2,3,6,7,8-HxCDF
2,3,4,6,7,8-HxCDF
1,2,3,7,8,9-HxCDF
1,2,3,4,7,8-HxCDD
1,2,3,6,7,8-HxCDD
1,2,3,7,8,9-HxCDD

NO
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND

(0.50)
(2.2)
(0.5)
(0.5)
(1.2)
(0.5)
(0.5)
(0.5)
(0.5)
(1.0)
(0.9)
(0.8)
(0.5)
(0.5)
4.0
ND (0.5)
30

1,2,3,4,6,7,8-HpCDF

1,2,3,4,7,8,9-HpCDF
1,2,3,4,6,7,8-HpCDD
OCDF
OCDD

75

�An experiment was designed to evaluate a procedure for cleaning the
activated acidic alumina immediately prior to the fractionation of the sample
extract. The acidic alumina (6.0 g) was packed in hexane. The packed column
was eluted with 40 ml of methylene chloride/hexane (1:1) solution followed by
80 to 100 ml of hexane. The sample extract was added to the column and was
eluted with 20 ml of hexane followed by 30 ml of 20% methylene chloride in
hexane which was reserved for PCDD and PCDF analysis.
The carbon-14 radiolabeled 2,3,7,8-TCDD, 1,2,3,6,7,8-HxCDD, and OCDD
were used to evaluate recovery of PCDDs from the cleaned alumina. Recoveries
of the radiolabeled PCDDs from the activated acidic alumina precleaned by the
procedure described above are detailed in Table 24. These data demonstrate
that the selected PCDDs are quantitatively (greater than 90%) recovered from
the precleaned acidic alumina. This procedure for cleanup of activated acidic
alumina has been integrated into the analytical protocol (Appendix A) for
routine application with sample preparation activities.
D. Absolute Recoveries of the Internal Quantisation Standards
The absolute recoveries of the carbon-13 labeled internal quantitation standards 13were determined by comparing responses with the internal recovery standard, C12-1,2,3,4-TCDD, which was added during final concentration
prior to HRGC/MS analysis. A summary of the average and range of recoveries
of the 8 internal quantisation standards from the 14 human adipose lipid
samples is provided in Table 25.
These data indicate that recoveries ranged from an average of 52.1%
for 13C12-2,3,7,8-TCDD up to 88.9% for 13C12-OCDD. The average recoveries
for the lower chlorinated internal standards were lower than the preliminary
method studies with carbon-14 radiolabeled standards had indicated. This resulted in a closer evaluation of the final concentration step prior to mass
spectrometry. The first extracts for the human adipose lipid extracts were
concentrated with a nitrogen evaporation system equipped with a water bath at
approximately 55°C. Final blowdown of the samples required addition of the
internal recovery standard in 10 uL of tridecane as a keeper solution. However, it was noted at the elevated temperature final volumes from nitrogen
evaporation were generally on the order of 2 to 5 uL. This required addition
of another 10 uL of tridecane prior to HRGC/MS analysis.
In an effort to assess the effect of reducing the final volume of
tridecane at elevated temperatures on absolute recoveries of the internal
quantisation standards, an experiment using the radiolabeled TCDD, HxCDD, and
OCDD standards was conducted.
Four solutions of the same spike level were prepared with each
radiolabeled compound in 1 ml of toluene. Two of the spiked solutions were
heated at 55-60°C and the solvent was reduced under a gentle stream of prepurified nitrogen. The toluene solution was concentrated to 100 uL, 500 uL
of 1% toluene in methylene chloride was added, and the solution was concentrated to 200 uL. At this time 10 pL of the keeper tridecane was added and
the solution was allowed to concentrate further. The remaining two solutions
for each radiolabeled compound were taken through a similar solvent exchange

76

�Table 24. Recovery of Radiolabeled PCDDs from
Precleaned Activated Alumina
Spike
level

(pg)

Compound

Recovery

14

100
300
300

92
96
97

14

1,000
3,000
3,000

103
101
100

14

2,500
7,500
7,500

102
99
97

C-2,3,7,8-TCDD

C-l,2,3,4,7,8-HxCDD

C-OCDD

77

�Table 25. Absolute Recoveries of the Internal Quantitation Standards
from the Human Adipose Lipid Matrix
Internal
quantisation
standard

Average
recovery ( )
%

Standard
deviation

Relative
standard
deviation (%)

13

64.4

7.9

12.3

46-78

13

52.1

5.0

9.6

43-62

13

76.1

8.9

11.7

62-90

13

57.1

3.5

6.1

54-64

13

59.4

5.0

8.4

54-70

13

63.6

5.3

8.4

57-77

76.3

10.3

13.6

61-99

88.9

11.4

12.9

67-104

C12-2,3,7,8-TCDF

C12-2,3,7,8-TCDD

C12-l,2,3,7,8-PeCDF

C12-l,2,3,7,8-PeCDD

C12-1,2,3,4,7,8HxCDF

C12-1,2,3,6,7,8HxCDD
13
c12-i,2,3,4,6,7,8-

Range of
recovery (%)

HpCDD

13

C12-OCDD

Values based on 14 analyses of human adipose lipid samples.

78

�and concentration procedure except the solution was allowed to concentrate at
room temperature.
One of the most obvious results was the observation that solutions
held at elevated temperatures could be reduced to dryness even when tridecane
had been added as a keeper. On the other hand, solutions for which tridecane
had been added but remained at room temperature could only be concentrated to
a 10-uL final volume. The recoveries of the radiolabeled standards from each
of the solutions in this study are presented in Table 26.
The results from this study indicate that the final concentration
condition may have a pronounced effect on the absolute recoveries of the PCDDs
and PCDFs, especially for the lower chlorinated congeners such as 2,3,7,8-TCDD.
However, it should be noted that the approach to target analyte quantisation
based on the internal standard method (isotope dilution for 8 of the 17 target
analytes) is not affected by absolute recoveries as low as 50%. The procedure
for final concentration in the analytical protocol (Appendix A) for the analysis of the NHATS samples for the EPA/VA study has been modified to specify
room temperature conditions.

79

�Table 26. Recovery of Carbon-14 Labeled 2,3,7,8-TCDD, 1,2,3,4,7,8-HxCDD,
and OCDD as a Function of Final Concentration Conditions
Spike
level
Compound

(pg)

Concentration
conditions

Observed
final
volume

Observed
recovery ( )
%

14

300
300
300
300

55-60°C
55-60°C
20°C
20°C

1-2 uL
dry ness
10 |jL
10 ML

78
54
98
93

14

3,000
3,000
3,000
3,000

55-60°C
55-60°C
20°C
20°C

1-2 ML

94
102
105

7,500
7,500
7,500
7,500

55-60°C
55-60°C
20°C
20°C

1-2
2-3
10
10

C-2,3,7,8-TCDD

C-l,2,3,4,7,8-HxCDD

14

C-OCDD

5 ML
10 ML
10 ML
ML
ML
ML
ML

107
94
94
100

97

Each solution was concentrated under a gentle stream of flowing nitrogen.

80

�VII. REFERENCES
1. Stanley JS. 1984. Methods of analysis of polychlorinated dibenzo-pdioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) in biological
matrices—literature review and recommendations. EPA-560/584-00.
2. Stanley JS, Going JE, Redford DP, Kutz KW, Young AL. 1985. A survey of
analytical methods for measurement of polychlorinated dibenzo-p_-dioxins
(PCDD) and polychlorinated dibenzofurans (PCDF) in human adipose tissues.
In: Chlorinated dioxins and dibenzofurans in the total environment II.
Keith LH, Rappe C, Choudhary G, eds. Butterworth Publishers, pp. 181-195.
3. Stanley JS. 1984 (March 28). Proposed analytical method for analysis
of PCDDs/PCDFs in human adipose tissue: special report. Washington, DC:
Office of Pesticides and Toxic Substances, U.S. Environmental Protection
Agency. Contract 68-02-3938, Work Assignment 8.
4. Stanley JS. 1986 (April 23). Broad scan analysis of human adipose tissue:
polychlorinated dibenzo-jD-dioxins (PCDDs) and polychlorinated dibenzofurans
(PCDFs). Draft final report. Washington, DC: Office of Pesticides and
Toxic Substances, U.S. Environmental Protection Agency. Contract 68-023938, Work Assignment 8.
5. Albro et al. 1985. Methods for the quantitative determination of multiple, specific polychlorinated dibenzo-p_-dioxin and dibenzofuran isomers
in human adipose tissue in the parts-per-trillion range. An interlaboratory study. Anal Chem 57: 2717-2725.
6. Patterson DG et al. 1986. High-resolution gas chromatographic/highresolution mass spectrometric analysis of human adipose tissue for
2,3,7,8-tetrachlorodibenzo-p_-dioxin. Anal Chem 58: 705-713.
7. Schecter A, Tiernan TO, Taylor ML, VanNess GF, Barrett JH, Wagel DJ,
Gitlitz G, Bogdasarian M. 1985. Biological markers after exposure to
polychlorinated dibenzo-p_-dioxins, dibenzofurans, biphenyls, and biphenylenes. Part I: Findings using fat biopsies to estimate exposure.
In: Chlorinated dioxins and dibenzofurans in the total environment II.
Keith LH, Rappe C, Choudhary G, eds. Butterworth Publishers, pp. 215-246.
8. Schecter A, Ryan JJ. 1985. Dioxin and furan levels in human adipose
tissue from exposed and control populations. 189th National ACS Meeting
Symposium on Chlorinated Dioxins and Dibenzofurans in the Total Environment III, Miami, Florida. Preprint Division of Environmental Chemistry,
ACS 25:160-163, Paper No. 56.
9. Ryan JJ, Williams DT, Lau BPY, Sakuma T. 1985. Analysis of human fat
tissue for 2,3,7,8-tetrachlorodibenzo-jD-dioxin and chlorinated dibenzofuran residues. In: Chlorinated dioxins and dibenzofurans in the total
environment II. Keith LH, Rappe C, Choudhary G, eds. Butterworth Publishers, pp. 205-214.

81

�10. Ryan JJ, Schecter A, Lizotte R, Sun W-F, Miller L. 1985. Tissue distribution of dioxins and furans in humans from the general population.
Chemosphere 14: 929-932.
11. Nygren M, Hansson M, Rappe C, Domellof L, Hardell L. 1985. Analysis of
polychlorinated dibenzo-p_-dioxins and dibenzofurans in adipose tissue
from soft-tissue sarcoma patients and controls. 189th National ACS
Meeting Symposium on Chlorinated Dioxins and Dibenzofurans in the Total
Environment III, Miami, Florida, 1985. Preprint Division of Environmental Chemistry, ACS 25:160-163, Paper No. 55.
12. Smith LM, Stalling DL, Johnson JJ. 1984. Determination of part per
trillion levels of polychlorinated dibenzofurans and dioxins in environmental samples. Anal Chem 58: 1830-1842.
13. Rappe C, Nygren M, Linstrom G, Hanson H. 1985. Dioxins and dibenzofurans in human tissues and milk of European origin. 5th International
Symposium on Chlorinated Dioxins and Related Compounds, Bayreuth, FRG,
September 16-19, 1985.
14. Ryan JJ. 1985. Variation of dioxins and furans in humans with age and
organ by country. 5th International Symposium on Chlorinated Dioxins
and Related Compounds, Bayreuth, FRG, September 16-19, 1985.
15. Graham M, Hileman FD, Wendling J, Wilson JD. 1985. Chlorocarbons in
adipose tissue samples. 5th International Symposium on Chlorinated
Dioxins and Related Compounds, Bayreuth, FRG, September 16-19, 1985.
16. Patterson DG, Holler JS, Smith SJ, Liddle JA, Sampson EJ, Needham LL
1985. Human tissue data in certain U.S. populations. 5th International
Symposium on Chlorinated Dioxins and Related Compounds, Bayreuth, FRG,
September 16-19, 1985.
17. Patterson DG, Holler JS, Groce DF, Alexander LR, Lapeza CR, 0'Conner RC,
Liddle JA. 1986. Control of interferences in the analysis of human
adipose tissue to 2,3,7,8-tetrachlorodibenzo-p_-dioxin (TCDD). Environ
Toxicol Chem 5: 355-360.
18. Holler JS, Patterson DG, Alexander LR, Groce OF, O'Connor RC, Lapeza CR.
1985. Control of artifacts and contamination in the development of a
dioxin analytical program. 33rd Annual Conference on Mass Spectrometry
and Allied Topics, San Diego, CA, May 26-31, 1985.

82

�APPENDIX A
ANALYTICAL PROTOCOL FOR DETERMINATION OF PCDDs AND PCDFs
IN HUMAN ADIPOSE TISSUE

A-l

�TABLE OF CONTENTS

Section

Description

Page

1

Scope and Application

A-3

2

Summary of Method

A-3

3

Definitions

4

Interferences

A-7

5

Safety

A-7

6

Apparatus and Equipment

A-8

7

Reagents and Standard Solutions

A-ll

8

High Resolution Gas Chromatography/Mass Spectrometry
Performance Criteria.

A-13

Quality Control Procedures

A-30

10

Sample Preservation and Handling

A-32

11

Sample Extraction

A-33

12

Cleanup Procedures

A-35

13

Analytical Procedures

A-37

14

Date Reduction

A-42

15

Reporting and Documentation

A-47

9

.

A-2

A-6

�ANALYTICAL PROTOCOL FOR DETERMINATION OF PCDDs AND PCDFs
IN HUMAN ADIPOSE TISSUE
1.

SCOPE AND APPLICATION

1.1

1.2

The minimum measurable concentration is estimated to range from
1 pg/g (1 part per trillion) for 2,3,7,8-TCDD and 2,3,7,8-TCDF up
to 5 pg/g for OCDD and OCDF. However, these detection limits
depend on the kinds and concentrations of interfering compounds
in the sample matrix and the absolute method recovery.

1.3

2.

This method provides procedures for the detection and quantitative
measurement of polychlorinated dibenzo-p_-dioxins (PCDD) and polychlorinated dibenzofurans (PCDF) at concentrations ranging from 1
to 100 pg/g for the tetrachloro congeners up to 5 to 500 pg/g for
the octachloro congeners in 10-g aliquots of human adipose tissue.

The method will be used to determine PCDDs and PCDFs, particularly congeners with chlorine substitution in the 2,3,7,8 positions. Table 1 lists the specific PCDDs and PCDFs and target
method detection limits.

SUMMARY OF METHOD

Figure 1 presents a schematic of the analtyical procedures for determination of PCDDs and PCDFs in human adipose tissue. The analytical
method requires extraction and isolation of lipid materials from human
adipose samples. This is accomplished using sample sizes ranging up to
10 g. Extraction and homogenization are accomplished using methylene
chloride and a Tekmar Tissuemizer®. The extract is filtered through
anhydrous sodium sulfate to remove water. The extraction procedure is
repeated (three to five times) until the tissue sample has been thoroughly homogenized. The final extract is adjusted to a known volume
(100 ml) and the extractable lipid is determined using a minimum of 1%
of the final volume. The methylene chloride in the remaining extract is
concentrated until only an oily residue remains. The residue is spiked
with known amounts of the carbon-13 labeled PCDDs and PCDFs (e.g., 500 pg
of 13C12-TCDD/F to 2,500 pg of 13C12-OCDD/F) as internal quantisation
standards. The residue is diluted with hexane ( 200 ml), and 100 g of
^
sulfuric acid modified silica gel (40% w/w) is added to the solution with
stirring. The mixture is stirred for approximately 2 h, and the supernatant is decanted and filtered through anhydrous sodium sulfate. The
adsorbent is washed with at least two additional aliquots of hexane.
The combined hexane extracts are eluted through a column consisting of a
layer of sulfuric acid modified silica gel, and a layer of unmodified
silica gel. The eluate is concentrated to approximately 1 ml and added
to a column of acidic alumina. The PCDDs and PCDFs are eluted from the
alumina using 20% methylene chloride/hexane. This eluate is concentrated
to approximately 0.5 ml and is added to a 500-mg Carbopak C/Celite column.
The PCDDs and PCDFs are eluted from the column using 20 ml of toluene.
A-3

�Table 1. Target PCDD and PCDF Congeners and Target Method
Detection Limits
Compound
2,3,7,8-TCDD
2,3,7,8-TCDF
1,2,3, 7,8- PeCDD
1,2,3,7,8-PeCDF
2,3,4,7,8-PeCDF
1,2,3,4, 7,8-HxCDD
1,2,3,6,7,8-HxCDD
1,2,3,7,8,9-HxCDD
1,2,3,4,7,8-HxCDF
1,2,3,6,7,8-HxCDF
1, 2,3,7,8, 9-HxCDF
2,3,4,6,7,8-HxCDF
1,2,3,4,6,7,8-HpCDD
1,2,3,4,6,7,8-HpCDF
1,2,3,4,7,8,9-HpCDF
OCDD
OCDF

CAS no.

Target method detection
limit (pg/g)D

1746-01-6
51207-31-9
40321-76-4
57117-41-6
57117-31-4
39227-28-6
57653-85-7
19408-74-3
70648-29-9
57117-44-9
72918-21-9
60851-34-5
35822-46-9
67562-39-4
55673-89-7
3268-87-9
39001-02-0

1.0
1.0
1.0
1.0
1.0
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
5.0
5.0

Chemical Abstract Services number.
= parts per trillion.

A-4

�Initial Sample Preparation
Isolation of Extractable U'pid Materials

Homogenization in Methylene Chloride

I
Llpid Determination
Solvent Exchange
Add Internal Quantitation Standards (13C-PCDDs/PCDFs)
Bulk Lipid Removal
Acid Modified Silica Gel
Slurry Technique

Provides Cleanup of Oxidizable Compounds
with Rapid Sample Turnaround, Improved
Cleanup Efficiency and Recovery

Removal of Chemical InterferencesAcidic Silica/Silica
Acidic Alumina

Provides Seperation of PCBs and Other
Potential Interferences from PCDDs and PCDFs.

I
Carbopak C/Cel 7 te

Selective Adsorption and Isolation of PCDDs/PCDFs

Add Internal Recovery Standards
HRGC/MS-S1M Analysis

I

1

LRMS
I de nti fi cat i on/Quant? tati on
of Terra-6'cta PCDDs/PCDFs

HRMS
Confirmation of 2,3,7,8-TCDD

Figure 1. Schematic of the sample preparation and
instrumental analysis procedures for determination
of PCDDs and PCDFs in human adipose tissue.

A-5

�The toluene is concentrated to less than 1 mL and transferred to conical
vials. Tridecane (10 jjL) containing 500 pg of an internal recovery standard is added as a keeper, and the extract is concentrated to a final
volume.
The HRGC/MS analysis is completed in the selected ion monitoring mode
(SIM). Analysis of the tetra- through octachloro PCDD and PCDF congeners
is achieved using low resolution mass spectrometry. Separation of the
tetra- through octachloro PGDD and PCDF congeners is achieved using a
60-m DB-5 column. Verification of the 2,3,7,8-TCDD is achieved using a
50-m CP Sil 88 column and HRGC/MS-SIM analysis in the high resolution
mode (R = 10,000).
3.

DEFINITIONS
3.1

Concentration calibration solutions ~ Solutions containing known
amounts of the native analytes (unlabeled 2,3,7,8-substituted
PCDDs and PCDFs), the internal quantisation standards13(Carbon-13
labeled PCDDs and PCDFs), and the recovery standard, C121,2,3,4-TCDD. These calibration solutions are used to determine
instrument response of the analytes relative to the internal
quantisation standards and of the internal quantisation standards
relative to the internal recovery standard.

3.2

Internal quantitation standards — Carbon-13 labeled PCDDs and
PCDFs, which are added to every sample and are present at the
same concentration in every method blank and quality control
sample. These are added to the lipid residue extracted from the
adipose tissue and are used to measure the concentration of each
analyte. The concentration of each internal quantitation standard is measured in every sample, and percent recovery is determined using the internal recovery standard.

3.3

Internal recovery standard -- 13C12-1,2,3,4-TCDD which is added
to every sample extract just before the final concentration step
and HRGC/MS-SIM analysis.

3.4

Laboratory method blank — This blank is prepared in the laboratory through performing all analytical procedures except addition
of a sample aliquot to the extraction vessel. A minimum of one
laboratory method blank will be analyzed with each batch of samples.

3.5

HRGC column performance check mixture ~ A mixture containing
known amounts of selected TCDD standards; it is used to demonstrate continued acceptable performance of the capillary column,
i.e., separation ( 25% valley on a 50-m CP Sil 88 or 60-m SP-2330
^
HRGC column) of 2,3,7,8-TCDD isomer from all other 21 TCDD isomers,
and to define the TCDD retention time window.

3.6

Relative response factor -- Response of the mass spectrometer to
a known amount of an analyte relative to a known amount of an
internal standard (quantitation or recovery).
A-6

�3.7
3.8

4.

Mass resolution check — Standard method used to demonstrate
static resolution of 10,000 minimum (10% valley definition).
Sample batch -- A sample batch consists of up to 10 human adipose
tissue samples, one method blank, 2 internal quality control (QC)
samples (spiked and unspiked), and an external performance audit
sample (blind spike).

INTERFERENCES
Chemicals which elute from the HRGC column with ± 10 scans of the internal and/or recovery standards and which produce within the retention time
window ions at any of the masses used to detect or quantify PCDDs, PCDFs,
or the internal quantisation and recovery standards are potential interferences. Most frequently encountered potential interferences are other
sample components that are extracted along with the PCDDs and PCDFs, e.g.,
PCBs, chlorinated methoxybiphenyls, chlorinated hydroxydiphenyl ethers,
chlorinated benzylphenyl ethers, chlorinated naphthalenes, DDE, DDT, etc.
The actual incidence of interference by these chemicals depends also
upon relative concentrations, mass spectrometric resolution, and chromatographic conditions. Because very low levels (pg/g) of PCDDs and
PCDFs are anticipated, the elimination of interferences is essential.
High purity reagents and solvents must be used and all equipment must be
scrupulously cleaned. Laboratory method blanks must be analyzed to demonstrate absence of contamination that would interfere with measurement of
the PCDDs and PCDFs. Column chromatographic procedures are used to remove
coextracted sample components; these procedures must be performed carefully to minimize loss of PCDDs and PCDFs during attempts to increase
their concentration relative to other sample components.

5.

SAFETY
5.1

The toxicity or carcinogenicity of each reagent used in this
method has not been precisely defined; however, each chemical
compound should be treated as a potential health hazard. The
2,3,7,8-TCDD is a known teratogen, mutagen, and carcinogen. Ingestion of microgram quantities can result in toxic effects. The
other 2,3,7,8-substituted PCDDs and PCDFs may exhibit teratogenic,
mutagenic, and carcinogenic effects. From this viewpoint, exposure to these chemicals must be reduced to the lowest possible
level by whatever means available. Only experienced personnel
will be allowed to work with these chemicals.

5.2

All laboratory personnel will be required to wear laboratory
coats or coveralls, gloves, and safety glasses. The neat standards, stock, and working solutions will be handled only in a
Class A fume hood or glove box. When manipulating stock standards or working solutions, the analyst is advised to place the
solution vials in a secure holder (sample block or glass beaker)
to prevent accidental spills.

A-7

�5.3

5.4

If handling of these compounds result's in skin contact, immediately remove all contaminated clothing and wash the affected skin
areas with soap and water for at least 15 min.

5.5

6.

If these standards are spilled, absorb as much as possible with
absorbent paper and place in a container clearly labeled as PCDD
or PCDF waste. Solvent-wash all contaminated surfaces with toluene and absorbent paper followed by washing with a strong soap
and water solution. Dispose of all contaminated materials in
sealed steel containers labeled as contaminated with PCDD and/or
PCDF residue and indicate the approximate level of contamination.
As a final precaution, prepare a wipe sample of the exposed surface area and include the wipe as part of the sample analysis
batch. This will be used to confirm that the work area is free
of contamination.

Disposal of laboratory wastes — All laboratory wastes (solvents
and absorbents) will be disposed of as hazardous wastes. The
laboratory personnel should take care to dispose of the sodium
sulfate, silica gel, and alumina in separate metal containers.
Excess solvents should be disposed of in gallon polyethylene jugs
containing a layer of activated charcoal. Excess solvent that is
known to be contaminated with PCDDs or PCDFs should be kept at a
minimum by evaporating the solvent with a stream of air.

APPARATUS AND EQUIPMENT
6.1

High Resolution Gas Chromatograph/Mass Spectrometer/Data System
(HRGC/HRMS/DS)

6.1.1

The GC must be equipped for temperature programming,
and all required accessories must be available, such as
syringes, gases, and a capillary column. The GC injection port must be designed for capillary columns. The
use of splitless injection techniques is recommended.
When using this method, a l-pL injection volume is used.
The injection volumes for all extracts, blanks, calibration solutions, and the performance check sample must
be consistent.

6.1.2

High Resolution Gas Chromatograph-Mass Spectrometer
Interface
The HRGC/MS interface is directly coupled to the mass
spectrometer ion source. All components of the interface should be glass or glass-lined stainless steel.
The interface components should be compatible with
300°C temperatures. The HRGC/MS interface must be
appropriately designed so that the separation of the
PCDDs and PCDFs which is achieved in the gas chromatographic column is not appreciably degraded. Cold spots
and/or active surfaces (adsorption sites) in the HRGC/MS
A-8

�interface can cause peak tailing and peak broadening.
It is recommended that the HRGC column be fitted directly
into the MS ion source. Graphite ferrules should be
avoided in the HRGC injection port since they may absorb PCDDs or PCDFs. Vespel or equivalent ferrules
are recommended.
6.1.3

Mass Spectrometer
The mass spectrometer must be capable of maintaining a
minimum resolution of 10,000 (10% valley) for high resolution confirmation analysis. The mass spectrometer
must be operated in a selected ion monitoring (SIM)
mode with total cycle time (including voltage reset
time) of 1 s or less.

6.1.4

Data System
A dedicated hardware or data system is required to control the rapid multiple ion monitoring process and to
acquire the data. Quantification data (peak areas or
peak heights) and SIM traces (displays of intensities
of each m/z (characteristic ion) being monitored as a
function of time) must be acquired during the analyses.
Quantifications may be reported based upon computergenerated peak areas or upon measured peak heights.

6.2

HRGC Columns
For isomer-specific determinations of 2,3,7,8-TCDD, the following
fused silica capillary columns are recommended: a 50-m CP-Sil 88
column and a 60-m SP-2330 (SP-2331) column. However, any capillary column which separates 2,3,7,8-TCDD from all other TCDDs may
be used for such analyses, provided that the minimum acceptance
criteria in Section 8 are met.

6.3

Miscellaneous Equipment
6.3.1

Nitrogen evaporation apparatus with variable flow rate.

6.3.2

Balance capable of accurately weighing to ± 0.01 g.

6.3.3

Water bath — equipped with concentric ring cover and
capable of being temperature-controlled.

6.3.4

Stainless steel spatulas or spoons.

6.3.5

Magnetic stirrers and stir bars.

6.3.6

High speed tissue homogenizer -- Tekmar Tissuemizer®
equipped with an EN-8 probe or equivalent.

6.3.7

Vacuum dessicator.
A-9

�6.4

Glassware
6.4.1

Erlenmeyer flask — 500 ml.

6.4.2

Kuderna-Danish apparatus -- 500-mL evaporating flask,
15-mL graduated concentrator tubes with ground-glass
stoppers, and three-ball macro Snyder column (Kontes
K-570001-0500, K-503000-0121, and K-569001-0219 or
equivalent).

6.4.3

Minivials -- 1-mL borosilicate glass with conical-shaped
reservoir and screw caps lined with Teflon®-faced silicone disks.

6.4.4

Powder funnels -- glass.

6.4.5

Chromatographic columns for the silica and alumina
chromatography -- 1 cm ID x 10 cm long and 1 cm ID x
30 cm long with 250-mL reservoir and equipped with TFE
stopcocks.

6.4.6

Chromatographic column for the Carbopak cleanup —
disposable 5-mL graduated glass pi pets, 6 to 7 mm ID.

6.4.7

Glass rods.

6.4.8

Carborundum boiling chips -- Extracted for 6 hr in a
Soxhlet apparatus with benzene and air dried.

6.4.9

Glass wool, silanized (Supelco) — Extract with methylene
chloride and hexane and air dry before use.

6.4.10

Glassware cleaning procedure -- All glassware used for
these analyses will be cleaned via the following procedure. Wash the glassware in soap and water, rinse with
copious amounts of tap water, distilled water, and
distilled-in-glass acetone, in that order. Immediately
prior to use, the glassware should be rinsed with
distilled-in-glass quality solvents: methylene chloride,
toluene, and hexane. The glassware should be allowed
to dry fully.
As an added precuation, all glassware will be marked
with a unique code that should be noted in the extraction and cleanup procedures for each sample. This
glassware tracking will allow background results from
specific glassware to be documented.
After use, each piece of glassware should be rinsed
with the last solvent used in it, followed by a rinse
with toluene, then acetone, before transferring it to
the glassware washing facility.

A-10

�7.

REAGENTS AND STANDARD SOLUTIONS

7.1

Column Chromatography Reagents
7.1.1

Alumina, acidic (Biorad, AG-4) -- Extract the alumina
in a Soxhlet apparatus with methylene chloride for 18 h
(minimum of two cycles per hour). Air dry and activate
it by heating in a foil-covered glass container for 24 h
at 190°C.

7.1.2

Silica gel -- High purity grade, type 60, 70-230 mesh;
extract the silica gel in a Soxhlet apparatus with
methylene chloride for 10 h (minimum of 2 cycles per
hour). Air dry and activate it by heating in a foilcovered glass container for 24 h at 130°C.

7.1.3

Silica gel impregnated with 40% (by weight) sulfuric
acid -- Add two parts (by weight) concentrated sulfuric
acid to three parts (by weight) silica gel (extracted
and activated) (e.g., 40 g of H2S04 plus 60 g of silica
gel) in a glass screw-cap bottle. Tumble for 5 to 6 h,
shaking occasionally until free of lumps.

7.1.4

Sulfuric acid, concentrated -- ACS grade, specific
gravity 1.84.

7.1.5

Graphitized carbon black (Carbopack C, Supelco), surface of approximately 12 mVg, 80/100 mesh -- Mix thoroughly 3.6 g of Carbopack C and 16.4 g of Celite 545®
in a 40-mL vial. Activate at 130°C for 6 h. Store in
a desiccator.

7.1.6

Celite 545® (Fischer Scientific), reagent grade, or
equivalent.

7.2

Desiccating agents -- Sodium sulfate; granular, anhydrous. Before
use extract with methylene chloride for 16 h (minimum of two cycles per hour), air dry and then muffle for ^ 4 h in a shallow
tray at 400°C. Let it cool in a desiccator and store in oven at
130°C.

7.3

Solvents -- High purity, distilled in glass: methylene chloride,
toluene, benzene, cyclohexane, methanol, acetone, hexane; reagent
grade: tridecane. High purity solvents are dispensed from Teflon®
squirt bottles.

7.4

Concentration Calibration Solutions (Table 2)
Eight tridecane solutions containing native calibration standards,
13
C12-labeled internal quantisation standards, and two internal
recovery standards are required. The complete compound list is

A-11

�Table 2. Concentration Calibration Solutions
Compound
Native

Concentration in cal ibration solutions i n pg/uL
CS1
CS2
CS3
CS4
CSS
CS6
CS7
CSS

2,3,7,8-TCDD
2,3,7,8-TCDF
1,2,3,7,8-PeCDD
1,2,3, 7,8-PeCDF
2,3,4,7,8-PeCDF
1,2,3,4, 7,8-HxCDD
1,2,3,6,7,8-HxCDD
1,2,3,7,8,9-HxCDD
1,2,3,4,7,8-HxCDF
1,2,3,6,7,8-HxCDF
1,2,3,7,8,9-HxCDF
2,3,4,6,7,8-HxCDF
1,2,3,4,6,7,8-HpCDD
1,2,3,4,6,7,8-HpCDF
1,2,3,4,7,8,9-HpCDF
OCDD
OCDF
Internal Quantisation
Standards
13
C12-2,3,7,8-TCDD
13
C12-2,3,7,8-TCDF
13
C12-l,2,3,7,8-PeCDD
13
C12-l,2,3,7,8-PeCDF
13
C12-l,2,3,6,7,8-HxCDD
13
C12-l,2,3,4,7,8-HxCDF
13
C12-l,2,3,4,6,7,8-HpCDD
13
C12-OCDD
Internal Recovery
Standard
13
C12-1,2,3,4-TCDD

200
200
200
200
200
500
500
500
500
500
500
500
500
500
500
1,000
1,000

100
100
100
100
100
250
250
250
250
250
250
250
250

50
50
50
50
50
125
125
125
125

25
25
25
25
25
62. 5

250
500
500

250

62. 5
62. 5
62. 5
62. 5
62. 5
62. 5
62. 5
62. 5
62. 5
125

250

125

250

125
125
125
125
125

125

10
10
10
10
10
25
25
25
25
25
25
25
25
25
25
50
50

50
50
50
50
125
125
125
250

50
50
50
50

50

50

50
50
50

125
125
125
250

125
125
125
250

50
50
50
125
125
125
250

50
50
50
50
125
125
125
250

50

50

50

50

50

A-12

5
5
5
5
5
12. 5
12. 5
12. 5
12. 5
12. 5
12. 5
12. 5
12. 5
12. 5
12. 5

25
25

50
50

2. 5

2. 5
2. 5
2. 5
2. 5
6. 25
6. 25
6. 25
6. 25
6. 25
6. 25
6. 25
6. 25
6. 25
6. 25
12. 5
12. 5

1
1
1
1
1
2.5

2.5
2.5
2.5
2.5

2.5
2.5
2.5
2.5
2.5
5
5

50
50
50
50
125
125

250

50
50
50
50
125
125
125
250

50

50

50

50
50
125
125

125

125
250

�given in Table 1. The native 2,3,7,8-TCDD is supplied as a certified standard solution from the U.S. EPA QA Reference Materials
Branch. All other native compounds were supplied in crystalline
form by Cambridge Isotope Laboratories (Woburn, MA). 13C12~
Labeled internal quantisation standards were supplied in solution
in ji-nonane by Cambridge Isotope Laboratories. Portions of the
native standards were accurately weighed to the nearest 0.001 mg
with a Cahn 27 electrobalance and dissolved in toluene.
7.5

Column Performance Check Mixture
The column performance check mixture consists of several TCDD
isomers which will be used to document the separation of 2,3,7,8TCDD from all other isomers. This solution will contain TCDDs
(A) eluting closely to 2,3,7,8-TCDD, and the first- (F) and lasteluting (L) TCDDs.
Analyte

Approximate amount per ampule

Unlabeled 2,3,7,8-TCDD
13
C12-2,3,7,8-TCDD
1,2,3,4-TCDD (A)
1,4,7,8-TCDD (A)
1,2,3,7-TCDD (A)
1,2,3,8-TCDD (A)
1,3,6,8-TCDD (F)
1,2,8,9-TCDD (L)
7.6

10
10
10
10
10
10
10
10

ng
ng
ng
ng
ng
ng
ng
ng

Spiking Solutions
Three solutions are prepared using the 13
same stock as in Section
7.4. A native standard solution and a C12 internal quantitation standard solution are prepared in isooctane (Tables 3 and
4). A recovery standard solution is prepared in tridecane (Table 4). Samples are spiked with 100 (jL of internal quantisation
standard solution and final sample extracts are spiked with 10 |jL
of internal recovery standard solution.

8.

HIGH RESOLUTION GAS CHROMATOGRAPHY/MASS SPECTROMETRY PERFORMANCE CRITERIA

Samples and standards are analyzed by using a Carlo Erba MFC500 gas chromatography (GC) coupled to a Kratos MS50TC double-focusing mass spectrometer (MS) to be operated in the electron impact mode. The HRGC/MS interface is simply a direct connection of the fused silica HRGC column to
the ion source of the MS via a heated interface oven. Data acquisition
and processing are controlled by a Finnigan-MAT Incos 2300 data system.

A-13

�Table 3. Native Spiking Solution
Concentration
(pg/uO

Compound
2,3,7,8-TCDD
2,3,7,8-TCDF
1,2,3,7,8-PeCDD
1,2,3,7,8-PeCDF
2,3,4,7,8-PeCDF
1,2,3,4,7,8-HxCDD
1,2,3,6,7,8-HxCDD
1,2,3,7,8,9-HxCDD
1,2,3,4,7,8-HxCDF
1,2,3,6,7,8-HxCDF
1,2,3,7,8,9-HxCDF
2,3,4,6,7,8-HxCDF
1,2,3,4,6,7,8-HpCDD
1,2,3,4,6,7,8-HpCDF
1,2,3,4,7,8,9-HpCDF
OCDD
OCDF

5
5
5
5
5
12.5
12.5
12.5
12.5
12.5
12.5
12.5
12.5
12.5
12.5
25
25

A-14

�Table 4. Internal Standard Spiking Solutions
Concentration
(pg/^L)

Compound
Internal Quanti tati on Standards
C12-2,3,7,8-TCDD

13

5

13

5

^Cia-l^.SJ.S-PeCDD

5

13

5

Ci2-2,3,7,8-TCDF

C12-l,2,3,7,8-PeCDF

13

12.5

13

12.5

13

12.5

C12-l,2,3,6,7,8-HxCDD

C12-l,2,3,4,7,8-HxCDF

C12-l,2,3,4,6,7,8-HpCDD

13

C12-OCDD

25

Internal Recovery Standard
13
C12-1,2,3,4-TCDD

A-15

5

�8.1

HRGC/MS Analysis of PCDD/PCDF
Single run selected ion monitoring (SIM) analysis of the tetrachloro through octachloro-dioxins and furans is carried out with
the instrumental conditions and parameters outlined in Table 5.
For each HRGC/MS run, five distinct groups of ions, which correspond to each chlorine level, are sequentially monitored. These
ion descriptors are shown in Table 6. The masses of the two most
abundant ions in the molecular ion cluster of each dioxin and furan
and isotopically labeled standard are monitored. In addition,
the masses corresponding to the molecular ions of the hexachloro
through decachlorodiphenyl ethers (PCDEs) are monitored to aid in
the confirmation of positive furan results. A lock mass, m/z 381
from PFK (perfluorokerosene), is used to observe and correct any
magnet/instrument drift during the analysis.
8.1.1

Tuning and Mass Calibration
The mass spectrometer is tuned on a daily basis to
yield optimum sensitivity and peak shape using an ion
peak (m/z 381) from PFK. The resolution is visually
monitored and maintained at £ 3,000 (10% valley definition) to provide adequate noise rejection while maintaining good ion transmission.
Mass calibration of the mass spectrometer for the HRGC/MS
• analysis of PCDD/PCDF is carried out on a daily basis.
The magnetic field is adjusted to pass m/z 300 at full
accelerating voltage. PFK is admitted to the MS and an
accelerating voltage scan from 8,000 to 4,000 V is acquired by the data system. This corresponds to an effective mass range of 301 to 593 amu. Upon completion of
a successful calibration step, the five ion descriptors
shown in Table 6 are updated to reflect the new mass
calibration.

8.1.2

Ion Descriptor Switching
The ion descriptors shown in Table 6 are sequentially
monitored during a PCDD/PCDF analysis to cover the retention windows of each chlorination level. The retention windows and hence the descriptor switch points are
determined initially and whenever a new HRGC column is
installed by injection of a mixture of PCDD and PCDF
congeners. Daily adjustment of the descriptor switch
times are performed when careful monitoring of the standard retention times shows this to be necessary. The
descriptors are designed to overlap to ensure acquisition of all isomers of each homolog.

A-16

�Table 5. HRGC/LRMS Operating Conditions for PCDD/PCDF Analysis
Mass spectrometer
Accelerating voltage:
Trap current:
Electron energy:
Electron multiplier voltage:
Source temperature:
Resolution:
Overall SIM cycle time:

8,000 V
500 |jA
70 eV
-1,800 V
280°C

£ 3,000 (10% valley definition)
1s

Gas chromatograph
Column coating:
Film thickness:
Column dimensions:
He linear velocity:
He head pressure:

DB-5
0.25 pm
60 m x 0.25 mm ID
* 25 cm/sec
1.75 kg/cm2 (25 psi)

Injection type:
Split flow:
Purge flow:
Injector temperature:
Interface temperature:
Injection size:
Initial temperature:
Initial time:
Temperature program:

Splitless, 45 s
30 mL/min
6 mL/min
270°C
300°C

1-2 (JL
200°C
2 min
200°C to 330°C at 5°C/min

A-17

�Table 6. Ions Monitored for HRGC/MS of PCDD/PCDF
Descriptor
Al

ID

Mass

TCDF

303.902
305.899
315.942
317.939
319.896
321.894
331.937
333.934
373.840
380.976

TCDD
13

C12-TCDD

HxDPE
PFK (lock mass)
TCDF
TCDD
PeCDF
13

C12-PeCDF

PeCDD
13

C12-PeCDD

PFK (lock mass)
HpCDPE
A3

HxCDF
PFK (lock mass)
13
C12-HxCDF
HxCDD
13

C12-HxCDD

OCDPE

A-18

0.045
0.045
0.045
0.045
0.045
0.045
0.045
0.045
0.045
0.045
0.045
0.045
0.035
0.035

373.821
375.818
380.976
385.861
387.858
389.816
391.813
401.856
403.853
443.759

C12-TCDF

0.090
0.090
0.090
0.090
0.090
0.090
0.090
0.090
0.090
0.090

303.902
305.899
319.896
321.894
337.863
337.860
349.903
351.900
353.858
355.855
365.898
367.895
380.976
407.801

13

A2

Nominal dwell
time (sec)

0.080
0.080
0.080
0.080
0.080
0.080
0.080
0.080
0.080
0.080

�Table 6 (continued)
Descriptor
A4

ID

Mass

PFK (lock mass)
HxCDD
HpCDF
13

C12-HpCDF

HpCDD
13

C12-HpCDD

37

Cl4-HpCDD

NCDPE
A5

PFK (lock mass)
OCDF
13

C12-OCDF

OCDD
13

C12-OCDD

DCDPE

A-19

Nominal dwell
time (sec)

380.976
389.816
391.813
407.782
409.779
419.822
421.819
423.777
425.774
435.817
437.814
429.768
431.765
477.720

0.040
0.040
0.040
0.040
0.040
0.040
0.040
0.040
0.040
0.040
0.040
0.040
0.040
0.040

380.976
441. 743
443.740
453.783
455.780
457.738
459.735
469.779
471.776
511.681

0.06
0.07
0.07
0.07
0.07
0.07
0.07
0.07
0.07
0.06

�8.1.3

HRGC Column Performance (60-m DB-5)
8.1.3.1

Inject 1 uL of the column performance check
solution (Section 7.7) and acquire selected
ion monitoring (SIM) data for m/z 320, 322,
332, and 334.

8.1.3.2

The chromatographic peak separation between
2,3,7,8-TCDD and the peaks representing
any other TCDD isomers should be resolved
with a valley of 30-60%, where
Valley % = (x/y)(100)
x = measured height of the valley between
the chromatographic peak corresponding to 2,3,7,8-TCDD and the peak of
the nearest TCDD isomer; and
y '= the peak height of 2,3,7,8-TCDD.
Figure 2 is an example of the separation of
a TCDD isomer mixture and the calculation
of isomer resolution.
It is the responsibility of the laboratory
to verify the conditions suitable for the
appropriate resolution of 2,3,7,8-TCDD from
all other TCDD isomers. The column performance check solution also contains the TCDD
isomers eluting first and last under the
analytical conditions specified in this
protocol, thus defining the retention time
window for total TCDD determination. Any
individual selected ion current profile or
the reconstructed total ion current
(m/z 320 + m/z 322) consititutes and
acceptable form of data presentation.

8.1.4

Initial Calibration for PCDD/PCDF Analysis
Initial calibration is required before any samples are
analyzed for PCDD/PCDF. Initial calibration is also
required if any routine calibration does not meet the
required criteria listed in Section 8.1.6.
8.1.4.1

Tune and calibrate the instrument with PFK
as outlined in Section 8.1.1.

8.1.4.2

Six concentration calibration solutions
listed in Table 2 will be analyzed for the
initial calibration phase.

A-20

�TCDD Isomer Mixture

78.7

2. 3. 7, 8,-TCDD
1, 2, 3, 4-/1,

2359290.

2, 3, 7-/L 2. 3, 8- TCDI
319.856
±0.500

A

320

100.0,

2998270.

A x 100% = 29%
322

3&gt;

321.855
± 0.500

A

59.6

1785850.
Q2-2. 3. 7, 8.-TCDD

INS

331.851
± 0.500

332

75.3

2256890.
333.850
± 0.500

334

28:00

28:24

28:48

29:12

29:36

30:00

30:24

30:48

Figure 2. Example of the separation of 2,3,7,8-TCDD from other TCDD
isomers on a 60 m DB-5 column.

Time

�8.1.4.3

8.1.4.4

Compute the relative response factors (RRFs)
for each analyte in the concentration calibration solution using the criteria for
positive identification of PCDD/PCDF's
given in Section 14.1 and the computational methods in Section 14.2.

8.1.4.5

Compute the means and their respective
relative standard deviations (% RSD) for
the RRFs from each triplicate analysis for
each analyte in the standard.

8.1.4.6

8.1.5

Using the HRGC and MS conditions in Table 5 and the SIM monitoring descriptors
in Table 6, analyze a 1-jjL aliquot of each
of the six concentration calibration solutions in triplicate.

Calculate the grand means (RRF) and their
respective RSDs using the six mean RRFs
for each analyte.

Criteria for Acceptable Initial Calibration
8.1.5.1

The % RSD for the response factors for each
triplicate analysis for each analyte must
be less than 30% except for the TCDD and
TCDF, which must be less than 20%.

8.1.5.2

The variation of the mean RRFs obtained
from the triplicate analysis must be less
than 30% except for the TCDD and TCDF which
must be less than 20%.

8.1.5.3

The SIM traces for all ions used for quantitation must present a signal-to-noise
(S/N) ratio of S 2.5. This includes analytes and isotopically labeled standards.

8.1.5.4

Isotopic ratios must be within ±20% of
the theoretical values (see Table 7).
NOTE: If the criteria for acceptable calibration listed abo've have been met, the
RRF can be considered independent of the
analyte quantity for the calibration concentration range. The mean RRF from triplicate determinations for unlabeled PCDD/
PCDFs and for the isotopically labeled
standards will be used for all calculations until routine calibration criteria
(Section 8.1.7) are no longer met. At such
time, new mean RRFs will be calculated from
a new set of six triplicate determinations.

A-22

�Table 7. Ion Ratios for HRGC/LRMS Analysis of PCDD/PCDF
Compound
TCDF
13
C12-TCDF
TCDD
13
C12-TCDD
PeCDF
13
C12-PeCDF
PeCDD
13
C12-PeCDD
HxCDF
13
C12-HxCDF
HxCDD
13
C12-HxCDD
HpCDF
13
C12-HpCDF
HpCDD
13
C12-HpCDD
OCDF
13
C12-OCDF
OCDD
13
C12-OCDD

Ions monitored

Theoretical ratio

304/306
316/318
320/322
332/334
338/340
350/352
354/356
366/368
374/376
386/388
390/392
402/404
408/410
420/422
424/426
436/438
442/444
454/456
458/460
470/472

0.76
0.76
0.76
0.76
0.61
0.61
0.61
0.61
1.22
1.22
1.22
1.22
1.02
1.02
1.02
1.02
0.87
0.87
0.87
0.87

A-23

Acceptabl e range

0.61 0.61 0.61 0.61 0.49 0.49 0.49 0.49 0.96 0.96 0.96 0.96 0.82 0.82 0.82 0.82 0.70 0.70 0.70 0.70 -

0.91
0.91
0.91
0.91
0.73
0.73
0.73
0.73
1.46
1.46
1.46
1.46
1.22
1.22
1.22
1.22
1.04
1.04
1.04
1.04

�8.1.6

Routine Calibrations
Routine calibrations must be performed at the beginning
of every day before actual sample analyses are performed
and as the last injection of every day.
8.1.6.1
8.1.6.2

8.1.7

Inject 1 uL of the concentration calibration solution CS 7 (see Table 2).
Compute the RRFs for each analyte in the
concentration calibration solution using
the criteria for positive identification
of PCDD/Fs given in Section 14.1 and the
computational methods in Section 14.2.

Criteria for Acceptable Routine Calibration
8.1.7.1

8.1.7.2

Isotopic ratios must be within 20% of the
theoretical value for each analyte and isotopically labeled standard (see Table 8).

8.1.7.3

8.2

The measured RRF for all analytes must be
within 30% of the mean values established
by triplicate analysis of the calibration
concentration solutions, except for TCDD
and TCDF, which must be within 20% of the
mean values established in the initial
calibration step.

If the above criteria are not met, a second
attempt may be made before repeating the
entire initialization process.

HRGC/HRMS Analysis (Isomer Specific TCDD Analysis)
Isomer specific analysis for 2,3,7,8-TCDD is carried out with the
instrumental conditions and parameters shown in Table 8. In addition to monitoring the masses of the most abundant molecular ions
of TCDD, an ion corresponding to the loss of COC1 from the molecular ion is monitored for verification purposes. Mass spectrometer
resolution is maintained at or above 10,000 (10% valley definition)
in order to increase the specificity of the analysis.
8.2.1

Tuning and Mass Calibration
8.2.1.1

The mass spectrometer must be operated in
the electron (impact) ionization mode.
Static resolving power of at least 10,000
(10% valley) must be demonstrated before
any analysis of a set of samples is performed. Static resolution checks must be
performed at the beginning and at the end

A-24

�Table 8. HRGC/HRMS Operating Conditions
Mass spectrometer
Accelerating voltage:
Trap current:
Electron energy:
Electron multiplier voltage:
Source temperature:
Resolution:

8,000 V
500 (jA
70 eV
2,000 V
280°C
10,000 (10% valley definition)

Sim Parameters
Identity

Mass

TCDD-COC1
TCDD
TCDD
13
C12-TCDD
13
C12-TCDD

0.15
0.15
0.15
0.15
0.15
0.10

258.930
319.897
321.894
331.937
333.934

PFK (lock mass)

Nominal dwel1 times (s)

280.983

Overall SIM cycle time = 1 s
Gas chromatqgraph
Column coating:
Film Thickness:
Column dimensions:

CP-Sil 88
0.2 pm
50 m x 0.22 mm ID

Helium linear velocity:
Helium head pressure:

•v 25 cm/s 2
1.75 kg/cm (25 psi)

Injection type:
Split flow:
Purge flow:
Injector temperature:
Interface temperature:
Injection size:
Initial temperature:
Initial time:
Temperature program:

Split!ess, 45 s
30 mL/min
6 mL/min
270°C
240°C
2 ML
200°C

1 min
200°C to 240°C at 4°C/min

A-25

�of each 12-h period of operation. However, it is recommended that a visual
check.(i.e., not documented) of the static
resolution be made before and after each
analysis.
8.2.1.2

8.2.1.3

8.2.2

The MS shall be tuned daily using PFK to
yield a resolution of at least 10,000 (10%
valley) and optimal response at m/z 254.986.
This step is followed by calibration of an
accelerating voltage scan of PFK beginning
at m/z 254 (typical calibration range is
255 to 493 amu). Other voltage scans from
the same data file are used to establish
and document both the resolution at m/z
316.983 and the mass measurement accuracy
at m/z 330.979.
Following calibration, the SIM experiment
descriptor is updated to reflect the new
calibration. Six masses (see Table 8) are
monitored by scanning ^ m/10,000 amu (atomic
mass units) over each mass. The total cycle
time is kept to 1 s. The m/z 280.983 ion
from PFK is used as a lock mass because it
is the most abundant PFK ion within the
range of m/z 255 to 334 and therefore permits the use of low partial pressures of
PFK, which minimizes PFK interferences at
the analytical masses.

Mass Measurement and Resolution Check
Using a PFK molecular leak, tune the instrument to meet
the minimum required resolving power of 10,000 (10% valley)
at m/z 254.986 (or any other mass reasonably close to
m/z 259). Calibrate the voltage sweep at least across
the mass range m/z 259 to m/z 334 and verify that m/z
330.979 from PFK (or any other mass close to m/z 334)
is measured within ± 5 ppm (i.e., 1.7 mmu, if m/z 331
is chosen) using m/z 254.986 as a reference. Documentation of the mass resolution must then be accomplished
by recording the peak profile of the PFK reference peak
m/z 318.979 (or any other reference peak at a mass close
to m/z 320/322). The format of the peak profile representation must allow manual determination of the resolution;
i.e., the horizontal axis must be a calibrated mass scale
(amu or ppm per division). The results of the peak width
measurement (performed at 5% of the maximum which corresponds to the 10% valley definition) must appear on the
hard copy and cannot exceed 100 ppm (or 31.9 mmu if m/z
319 is the chosen reference ion).

A-26

�8.2.3

HRGC Column Performance (50-m CP Sil 88/60-m SP-2330)
Prior to any HRGC/HRMS analysis of calibration solutions
on samples for 2,3,7,8-TCDD, the resolution of the HRGC
columns must be documented to be within allowable limits
in order to provide conditions adequate for unambiguous
isomer-specific analysis of 2,3,7,8-TCDD.
8.2.3.1

Inject 2 pL of the column performance check
solution and acquire selected ion monitoring (SIM) data for m/z 258.930, 319.897,
321.894, 331.937, and 333.934 within a
total cycle time of &lt; 1 s (Table 8).

8.2.3.2

The chromatographic peak separation between
2,3,7,8-TCDD and the peaks representing
any other TCDD isomers must be resolved
with a valley of ^ 25%, where
Valley % = (x/y)(100)
x = measured height of the valley between
the chromatographic peak corresponding to 2,3,7,8-TCDD and the peak of
the nearest TCDD isomer; and
y = the peak height of 2,3,7,8-TCDD.

8.2.3.3

If the above resolution requirement is not
met, corrective action must be taken and
acceptable resolution documented prior to
any further analyses. Corrective action
may include removal of the first meter of
the HRGC column, replacement or clearing
of the injector port, or complete replacement of the GC column.

8.2.3.4

The column performance check solution also
contains the TCDD isomers eluting first
and last under the analytical conditions
specified in this protocol, thus defining
the retention time window for total TCDD
determination. The peaks representing
2,3,7,8-TCDD and the first and the last
eluting TCDD isomer should be labeled and
identified as such on the chromatograms (F
and L, respectively). Any individual selected ion current profile or the reconstructed total ion current (m/z 259 + m/z
320 + m/z 322) constitutes an acceptable
form of data presentation.

A-27

�8.2.4

Initial Calibration for HRGC/HRMS 2,3,7,8-TCDD Analysis
Initial calibration is required before any samples are
analyzed for 2,3,7,8-TCDD. Initial calibration is also
required if any routine calibration does not meet the
required criteria listed in Section 8.2.6.
8.2.4.1

8.2.4.2

Tune and calibrate the instrument with PFK
as described in Section 8.2.1.-

8.2.4.3

Inject 1 uL of the column performance check
solution (Section 8.2.3) and acquire SIM
mass spectra data for m/z 258.930, 319.897,
321.894, 331.937, and 333.934 using a total
cycle time of S 1 s (see Table 8). The
laboratory must not perform any further
analysis until it has been demonstrated
and documented that the criterion listed
in Section 8.2.3.2 has been met.

8.2.4.4

Using the same GC and MS conditions (Table 8) that produced acceptable results
with the column performance check solution, analyze a l-(jl_ aliquot of each of
the six concentration calibration solutions in triplicate.

8.2.4.5

Calculate the RRFs for unlabeled 2,3,7,8TCDD relative to 13C12-2,3,7,8-TCDD and
the RRF for 13C12-2,3,7,8-TCDD relative to
13
C12-1,2,3,4-TCDD using the criteria for
positive identification of TCDD by HRGC/
HRMS given in Section 14.1 and the computational methods in Section 14.2.

8.2.4.6

Calculate the six means (RRFs) and their
respective relative standard deviations
( RSD) for the response factors from each
%
of the triplicate analyses for both unlabeled and 13C12-2,3,7,8-TCDD.

8.2.4.7

8.2.5

At least six of the concentration calibration solutions listed in Table 2 must be
utilized for the initial calibration.

Calculate the grand mean RRFs and their
respective relative standard deviations
( RSD) using the six mean RRFs.
%

Criteria for Acceptable Initial Calibration
The criteria listed below for acceptable calibration
must be met before analysis of any sample is performed.

A-28

�8.2.5.1

The percent relative standard deviation
(RSD) for the response factors from each
of the triplicate analyses for both unlabeled and 13C12-2,3,7,8-TCDD must be
less than 20%.

8.2.5.2

The variation of the six mean RRFs for unlabeled and 13C12-2,3,7,8-TCDD obtained
from the triplicate analyses must be less
than 20% RSD.

8.2.5.3

SIM traces for 2,3,7,8-TCDD must present a
signal-to-noise ratio of § 2.5 for m/z
258.930, m/z 319.897, and m/z 321.894.

8.2.5.4

SIM traces for 13C12-2,3,7,8-TCDD must
present a signal-to-noise ratio 5 2.5 for
m/z 331.937 and m/z 333.934.

8.2.5.5

Isotopic ratios for 320/322 and 332/334
must be within the allowed range (0.67 to
0.90).
NOTE: If the criteria for acceptable calibration listed above have been met, the
RRF can be considered independent of the
analyte quantity for the calibration concentration range. The mean RRF from six
triplicate determinations for unlabeled
2,3,7,8-TCDD and for 13C12-2,3,7,8-TCDD
will be used for all calculations until
routine calibration criteria (Section 8.2.6)
are no longer met. At such time, new mean
RRFs will be calculated from a new set of
four triplicate determinations.

8.2.6

Routine Calibrations
Routine calibrations must be performed at the beginning
of a 12-h period after successful mass resolution and
HRGC column performance check runs.
8.2.6.1

Inject 1 yL of the concentration calibration solution (CS5, Table 2) which contains
10 pg/|Jl of unlabeled 2,3,7,8-TCDD, 50.0
pg/HL of 13C12-2,3,7,8-TCDD, and 50 pg/|jL
of 13C12-1,2,3,4-TCDD. Using the same GC/
MS/DS conditions as used in Table 8, determine and document acceptable calibration
as provided below.

A-29

�8.2.7

Criteria for Acceptable Routine Calibration
The following criteria must be met before further analysis is performed. If these criteria are not met, corrective action must be taken and the instrument must be
recalibrated.
8.2.7.1

The measured RRF for unlabeled 2,3,7,8-TCDD
must be within 20% of the mean values established in the initial calibration by triplicate analyses of concentration calibration solutions.

8.2.7.2

The measured RRF for 13C12-2,3,7,8-TCDD
must be within 20% of the mean value established by triplicate analysis of the concentration calibration solutions during
the initial calibration.

8.2.7.3

Isotopic ratios must be within the allowed
range (0.61 to 0.90).

8.2.7.4

If one of the above criteria is not satisfied, a second attempt can be made before
repeating the entire initialization process.
NOTE: An initial calibration must be carried out whenever the routine calibration
solution is replaced by a new one from a
different lot.

9.

QUALITY CONTROL PROCEDURES
9.1

Summary of QC Analyses

9.1.1

Initial and routine calibration and instrument performance checks.

9.1.2

Analysis of a batch of samples with accompanying QC
analyses:
Sample batch -- 10 NHATS adipose tissue samples plus
additional QC analyses including 1 method blank, a control tissue and a spiked tissue sample.
"Blind" QC (external QC) samples may be submitted by an
external source (quality assurance group or independent
laboratory) and included among the batch of samples.
Blind samples include spiked samples, unidentified duplicates, and performance evaluation samples.

A-30

�9.2

Performance Evaluation Samples -- Included among the samples in
every third batch will be a solution provided by the quality control coordinator containing known amounts of unlabeled 2,3,7,8TCDD and/or other PCDD/PCDF isomers. The accuracy of measurements for performance evaluation samples should be in the range
of 70-130%.

9.3

Performance Check Solutions
9.3.1

9.4

At the beginning of each 12-h period during which samples are to be analyzed, an aliquot of the HRGC column
performance check solution shall be analyzed to demonstrate adequate HRGC resolution for selected TCDD isomers.

Method Blanks
9.4.1

A minimum of one method blank is generated with each
batch of samples. A method blank is generated by performing all steps detailed in the analytical procedure
using all reagents, standards, equipment, apparatus,
glassware, and solvents that would be used for a sample
analysis, but omit addition of the adipose tissue.
9.4.1.1

The method blank must contain the same
amounts of Carbon-13 labeled internal
quantitation standards that are added to
samples before bulk lipid cleanup.

9.4.1.2

An acceptable method blank exhibits no
positive response for any of the characteristic ions monitored.
9.4.1.2.1

9.4.1.2.2

9.5

If the above criterion is not
met, solvents, reagents, spiking solutions, apparatus, and
glassware are checked to locate
and eliminate the source of
contamination before any samples
are extracted and analyzed.
If new batches of reagents or
solvents contain interfering
contaminants, purify or discard them.

Control Samples -- Control samples are prepared from a bulk sample(s) of human adipose tissue or similar matrix (e.g., porcine
fat). This material is prepared by blending the tissue with
methylene chloride, drying the extract by eluting through anhydrous sodium sulfate, and removing the methylene chloride using
rotoevaporation at elevated temperatures (80°C). The evaporation
process should be extended to ensure all traces of the extraction

A-31

�solvent have been removed. The resulting oily matrix (lipid) is
subdivided into 10-g aliquots which are analyzed with each sample
batch. The results of the individual analysis will be used to
give a measure of precision from batch to batch over an entire
program. Sufficient tissue should be extracted to provide a
homogeneous lipid matrix that can be used over the total analysis
program. Enough lipid matrix is necessary to prepare the spiked
samples describe in Section 9.6.
9.6

Spiked Samples — Spiked lipid samples are prepared using a portion of the homogenized lipid described in Section 9.5. Sufficient spiked lipid matrix is prepared to provide a minimum of one
spiked sample per sample batch. It is recommended that a minimum
of three spiked levels of the matrix are prepared ranging from 10
to 50 times the estimated limit of detection for each compound.
Each analysis of spiked sample must be accompanied by analysis of
a control sample in order to make the necessary corrections for
background contribution before determining the accuracy of the
method (Equation 9-1).
Accuracy (%) = 100% x Cone, spiked samp^-conc. control sample Eq ^
9.7

Duplicate Sample Analysis -- When possible a duplicate analysis
of specific samples is included in the sample batch as an additional measure of method precision. It is suggested that the
total tissue sample is extracted to isolate lipids material and
then subdivided for duplicate analysis. Precision is calculated
as relative percent difference (RPD) where the differences in the
duplicate measurements (for each analyte) is divided by the average of the two measurements and multiplied by 100%.

9.8

External Samples ~ Samples submitted as blinds to the analyst
may consist of either performance solutions of PCDD and PCDF congeners or spiked sample matrices. These performance solutions or
samples should be submitted by a source external to the analytical
program (QA unit of analysis laboratory or independent laboratory).
Performance audit solutions are intended to evaluate instrument
calibration and quantisation procedures. Spiked blind samples
must be accompanied by the corresponding unspiked samples to correct concentrations for background concentration. The blind
spiked samples are intended to evaluate the total analytical procedure. The analyst must keep in mind that it is necessary to
compare differences in standard sources for each type of external
sample.

10. SAMPLE PRESERVATION AND HANDLING

All adipose tissue samples must be maintained at less than -20°C from
time of collection. The analyst should instruct the collaborator collecting the sample(s) to avoid the use of chlorinated materials. Samples are handled using stainless steel forceps, spatulas, or scissors.

A-32

�Aliquots of samples removed from sample bottles not used for analysis
are disposed rather than returned to the sample vial. All sample bottles (glass) are cleaned as specified in Section 6.4.10. Teflon®-!ined
caps should be used. As with any biological sample, the analyst should
avoid any undue exposure.
11. SAMPLE EXTRACTION

11.1

Extraction of Adipose Tissue
11.1.1

Accurately weigh to the nearest 0.01 g a 10-g portion
of a frozen adipose tissue sample into a culture tube
(2.2 x 15 cm).
Note: Sample size may be smaller, depending on availability.

11.1.2

11.1.3

Allow the mixture to separate and decant the methylene
chloride extract from the residual solid material using
a disposable pipette. The methylene chloride is eluted
through a filter funnel containing a plug of clean glass
wool and 5 to 10 g of anhydrous sodium sulfate. The
dried extract is collected in a 100-mL volumetric flask.

11.1.4

A second 10-mL aliquot of methylene chloride is added
to the sample and homogenized for 1 min. The methylene
chloride is decanted, dried, and transferred to the
100-mL volumetric flask as specified in Section 11.1.3

11.1.5

The culture tube is rinsed with at least two additional
aliquots (10 mL each) of methylene chloride, and the
entire contents are transferred to the filter funnel
containing the anhydrous sodium sulfate. The filter
funnel and contents are rinsed with additional methylene
chloride (20 to 40 mL). The total eluent from the filter funnel is collected in the 100-mL volumetric flask.
Discard the sodium sulfate.

11.1.6

11.2

Allow the adipose tissue specimen to reach room temperature. Add 10 ml of methylene chloride and homogenize
the mixture for approximately 1 min with a Tekmar
Tissuemizer®.

The final volume of the extract for each sample is adjusted to 100 mL in the volumetric flask using methylene
chloride.

Lipid Determination
11.2.1

Preweigh a clean 1-dram glass vial to the nearest
0.0001 g using an analytical balance tared to zero.

A-33

�11.2.2

Accurately transfer 1.0 ml of the final extract (100 ml)
from Section 11.1.6 to the 1-dram vial. Reduce the volume of methylene chloride from the extract using a water
bath (50-60°C) gentle stream of purified nitrogen until
an oil residue remains.

11.2.3

Accurately weigh the 1-dram vial and residue to the
nearest 0.0001 g and calculate the weight of lipid
present in the vial based on difference. Nitrogen
blow-down is continued until a constant weight is
achieved.

11.2.4

Calculate the percent lipid content of the original
sample to the nearest 0.1% as shown in Equation 11-1.
I D ^

PYT

Lipid content, LC (%) = r^ X V r x 100%
^
W
AT

Eq. 11-1

AL

where: W.R = weight of the lipid residue to the
nearest 0.0001 g calculated from
Section 11.2.3 (100.0 ml);
VtAI = total volume of the extract in mL from
FYT
Section 11.1.6;
W.,. = weight of the original adipose tissue
samples to the nearest 0.01 g from
Section 11.1.1; and
V.. = volume of the aliquot of the final extract in ml used for the quantitative
measure of the lipid residue (1.0 mL).
11.2.5
11.3

Record the lipid residue measured in Section 11.2.3 and
the percent lipid content calculated from Section 11.2.4.

Extract Concentration
11.3.1

11.3.2
11.4

Quantitatively transfer the remaining extract volume
(99.0 mL) to a 500-mL Erlenmeyer flask. Rinse the volumetric flask with 20 to 30 mL of additional methylene
chloride to ensure quantitative transfer.
Place the Erlenmeyer flask on a hot plate at 40°C to
remove solvent until an oily residue remains.

Addition of Internal Quantisation Standards
To each lipid residue add the carbon-13 internal quantisation
spiking solution (Section 7.8) such that it delivers 500 to
2,500 pg of each of the surrogates specified in Table 4 in a
100-(jL volume.
A-34

�12. CLEANUP PROCEDURES
12.1

Bulk Lipid Removal
12.1.1

Add a total of 200 ml of n-hexane to the spiked lipid
residue in the 500-mL Erlenmeyer flask.

12.1.2

Slowly add, with stirring, 100 g of the 40% w/w sulfuric
acid impregnated silica gel (Section 7.1.3). Stir with
a magnetic stir-plate for 2 h.

12.1.3

Allow solids to settle and decant liquid through a powder
funnel containing 20 g of anhydrous sodium sulfate and
collect in a 500-mL sample bottle.

12.1.4

Rinse solids with two 50-mL portions of hexane. Stir
each rinse for 15 min, decant, and dry by elution through
sodium sulfate combining the hexane extracts from Section 12.1.3.

12.1.5

After the rinses have gone through the sodium sulfate,
rinse the sodium sulfate with an additional 25 mL of
hexane and combine with the hexane extracts from Section 12.1.4.

12.1.6

Prepare an acidic silica column as follows: Pack a
1 cm x 10 cm chromatographic column with a glass wool
plug, add approximately 25 mL of hexane, 1.0 g of silica
gel (Section 7.1.2), and 4.0 g of 40% w/w sulfuric acid
impregnated silica gel (Section 7.1.3). Pack a second
chromatographic column (1 cm x 30 cm) with a glass wool
plug, approximately 25 mL of hexane, 6.0 g of acidic
alumina (Section 7.1.1), and top with a 1-cm layer of
sodium sulfate (Section 7.4). Elute the combined hexane solutions (Section 12.1.5) through the columns until
the solvent level reaches the top of the chromatographic
packing. Inspect columns to ensure they are free of
channels and air bubbles. Wash the alumina column with
40 mL of 50% v/v methylene chloride/hexane. Remove
methylene chloride from the adsorbent by eluting the
column with an additional 100 mL of hexane.

12.1.7

Quantitatively transfer the hexane extract from the
Erlenmeyer flask (Sections 12.1.3 through 12.1.5) to
the silica gel column reservoir. Allow the hexane extract to percolate through the column and collect in a
KD concentrator.

12.1.8

Complete the elution of the extract from the silica gel
column with 50 mL of hexane in the KD concentrator.
Concentrate the eluate to approximately mL, using nitrogen blow-down as necessary.

A-35

�Note: If the 40% sulfuric acid/silica gel is noted to
be highly discolored throughout the length of the adsorbent bed it is necessary to repeat the cleaning procedure beginning with Section 12.1.1.
12.2

Separation of Chemical Interferences
12.2.1

Transfer the concentrate (1.0 ml) to the top of the
alumina column. Rinse the K-D assembly with two 1.0-mL
portions of hexane and transfer the rinses to the top
of the alumina column. Elute the alumina column with
18 ml of hexane until the hexane level is just below
the top of the sodium sulfate. Discard the eluate.
Columns must not be allowed to reach dryness (i.e., a
solvent "head" must be maintained).

12.2.2

Place 30 ml of 20% (v/v) methylene chloride in hexane
on top of the alumina and elute the TCDDs from the column. Collect this fraction in a 50-mL culture tube.

12.2.3

Prepare an 18% Carbopak C/Celite 545® mixture by thoroughly mixing 3.6 g of Carbopak C (80/100 mesh) and
16.4 g of Celite 545® in a 40-mL vial. Activate at
130°C for 6 h. Store in a desiccator. Cut off a clean
5-mL disposable glass pipet (6 to 7 mm ID) at the 4-mL
mark. Insert a plug of glass wool (Section 7.3) and
push to the 2-mL mark. Add 500 mg of the activated
Carbopak/Celite mixture followed by another glass wool
plug. Using two glass rods, push both glass wool plugs
simultaneously towards the Carbopak/Celite mixture and
gently compress the Carbopak/Celite plug to a length of
2 to 2.5 cm. Pre-elute the column with 2 ml of toluene
followed by 1 ml of 75:20:5 methylene chloride/methanol/
benzene, 1 ml of 1:1 cyclohexane in methylene chloride,
and 2 ml of hexane. The flow rate should be less than
0.5 mL/min. While the column is still wet with hexane,
add the entire eluate (30 ml) from the alumina column
(Section 12.2.2) to the top of the column. Rinse the
culture tube which contained the extract twice with 1 ml
of hexane and add the rinsates to the top of the column.
Elute the column sequentially with two 1-mL aliquots of
hexane, 1 ml of 1:1 cyclohexane in methylene chloride,
and I ml of 75:20:5 methylene chloride/methanol/benzene.
Turn the column upside down and elute the PCDD/PCDF fraction with 20 ml of toluene into 6-dram vial.

12.2A

Warm the vial to approximately 60°C and reduce the toluene volume to approximately 1 ml using a stream of
nitrogen. Carefully transfer the concentrate into a
1-mL minivial and reduce the volume to about 200 nL
using a stream of nitrogen.

A-36

�12.2.5

Rinse the concentrator tube with three washings using
500 ML of 1% toluene in CH2C12 (Section 12.2.5) concentrated to 200-500 ML and add 10 ML of the tridecane
solution containing the internal recovery standard and
store the sample in a refrigerator until HRGC/MS analysis.

12.2.6

Immediately prior to analysis, using a gentle stream of
nitrogen at room temperature, remove toluene and methylene
chloride. Submit sample to HRGC/MS once a stable 10 ML
volume of tridecane is attained.

13. ANALYTICAL

13.1

PROCEDURES

HRGC/MS Analysis for PCDD/PCDF
13.1.1

Once routine calibration criteria are met, the instrument is ready for sample analysis. Prior to the first
sample, a blank injection of tridecane should be analyzed
to document system cleanliness. If any evidence of system contamination is found, corrective action must be
taken and another tridecane blank analyzed.
The typical daily sequence of injections is shown in
Table 9 and Figure 3.
Note: Syringe Technique — Congeners of PCDD/PCDF in the
syringes used for HRGC/MS analysis can be problematic unless the syringes are properly handled between samples.
The following procedure has been found to be very effective for PCDD/PCDF removal from contaminated syringes
and will be used throughout these analyses.
• Rinse the syringe 10 times with isooctane.
• Fill the syringe with toluene and sonicate syringe
and plunger in toluene for 5 min and repeat at least
twice.
• Rinse the syringe 10 times with tridecane and pull
up 1 ML of clean tridecane.
• Syringe is ready for use.
At no time should air be introduced into the HRGC column
by using an air plug in the syringe. The oxygen present
in the air plug will quickly degrade a nonbonded GC phase.

13.1.2

Inject a 1-ML aliquot of the extract into the GC, operated under the conditions previously used (Section 8.1)
to produce acceptable results with the performance check
solution.

A-37

�Table 9. Typical Daily Sequence for PCDD/PCDF Analysis
1. Tune and calibrate mass scale versus perfluorokerosene (PFK).
2. Inject concentration calibration solution 2.5 to 12.5 pg/(jL (CS-7)
solution.
3. Inject blank (tridecane).
4. Inject samples 1 through "N".
5

Inject concentration calibration solution 2.5 to 12.5 pg/uL (CS-7)
solution.

A-38

�INSTRUMENTAL ANALYSIS

Instrument Mass Calibration vs PFK

I
Column Performance Evaluation

Does Column
Performance Meet
Minimum Resolution
Requirements?

No

Adjust Column
Length or Install
New Column

No

Reanalyze or Prepare Fresh
Calibration Standards and
Calibration Curve

Yes

Calibration Standard Analysis

Do Relative
Response Factors Meet
Criteria Based on Initial
Calibrations ?
Yes

Proceed with Sample Analysis

Figure 3. Daily QA procedures for proceeding with sample analysis.

A-39

�13.1.3

Acquire SIM data according to the same acquisition and
MS operating conditions previously used (Section 8.1)
to determine the relative response factors.
13.1.3.1
13.1.3.2

13.2

Acquire SIM data for the characteristic
ions designated in Table 6.
Instrument performance shall be monitored
by examining and recording 13 peak areas
the
for the recovery standard, C12-1,2,3,4-TCDD.
If this area should decrease to less than
50% of the previous run, sample analyses
shall be stopped until the problem is found
and corrected.

HRGC/HRMS Confirmation of 2,3,7,8-TCDD
13.2.1

Once the daily criteria of mass calibration, mass resolution, HRGC performance, and routine calibration are
met and documented, the instrument is ready for sample
analysis. Prior to the first sample, a blank injection
of tridecane will be made to document system cleanliness.
The typical daily schedule for HRGC/HRMS analysis of
TCDD is shown in Table 10 and Figure 3.

13.2.2

Inject a 1-uL aliquot of the extract into the GC, operated under the conditions previously used (Section 8.1)
to produce acceptable results with the performance check
solution.

13.2.3

Acquire SIM data according to Section 12.3.1. Use the
same acquisition and MS operating conditions previously
used (Section 8.3.4) to determine the relative response
factors.
13.2.3.1

Acquire SIM data for the following selected
characteristic ions:
m/z

Compound

258.930

TCDD - COC1

319.897

Unlabeled TCDD

321.894

Unlabeled TCDD

331.937

13
C12-2,3,7,8-TCDD,
13
C12-1,2,3,4-TCDD

333.934

13
C12-2,3,7,8-TCDD,
13
C12-1S2,3,4-TCDD

A-40

�Table 10. Typical Daily Schedule for HRGC/HRMS Analysis of TCDD
1. Tune and calibrate mass scale.
2. Perform mass measurement check and mass resolution check.
3. Inject column performance check solution.
4. Inject the routine concentration calibration solution.
5. Inject tridecane blank.
6. Inject samples I through "N".
7. Inject column performance check solution.
8. Mass resolution check.

A-41

�14. DATA REDUCTION

In this section, the
the analysis of data
HRGC/HRMS method for
qualitative criteria
14.1

procedures for the data reduction are outlined for
from both the HRGC/MS method for PCDD/PCDF and the
2,3,7,8-TCDD. Figure 4 presents a schematic of the
for identifying PCDDs and PCDFs.

Qualitative Identification
14.1.1

14.1.2

The ion current intensities for a particular PCDD/PCDF
must be S 2.5 times the noise level (S/N S 2.5) for
positive identification of that isomer.

14.1.3

The integrated ion current ratios of the analytical
masses for a particular PCDD/PCDF must fall within the
ranges shown in Table 7.

14.1.4
14.2

The ion current responses for each mass for a particular
PCDD/PCDF analyte must be within ± 1 s to attain positive identification of that analyte. For example,
m/z 338 and m/z 340 must have maximum peak responses
that are within ± 1 s to be positively identified as
a pentachlorodibenzofuran.

The recovery of the internal quantisation standards
should be between 50 and 115%.

Quantitative Calculations
14.2.1

Relative response factors (RRF). RRFs are calculated
from the data obtained during the analysis of concentration calibration solutions using the following formula:
C
A
x
IS
RRF = -^ ' j£
A
C

Eq. 14-1

IS ' x

where A

= the sum of the integrated ion
for the analyte in question.
for TCDD, A would be the sum
grated ion abundances for m/z

abundances
For example,
of the inte320 and 322;

A,s = the sum of the integrated ion abundances
for the labeled PCDD/F used as the internal
quantisation standard for the above analyte.
For example, for 13C12-TCDD, A,s would be
the sum of the integrated ion abundance for
m/z 332 and 334.
C

= concentration of the analyte in

A-42

�HRGC/MS-SIM Data

Response to
Characteristic Molecular
Ions within the Appropriate
Homolog Retention
Window?

Report Compounds as
Not Detected (ND)
Calculate Sample LOD

Characteristic
Ion Ratios within "±20%
Theoretical?

Response Due to
Coextracted Interference

Response
Correspondsito Specific
Isomerj Retention
Time?

'Quantitate Compound
as Per Protocol
Report as Isomer Unknown

Quantitate Specific Isomer as per Protocol

Figure 4. Qualitative criteria for identifying
PCDDs and PCDFs.

A-43

�CjS = concentration of the internal quantisation
standard in pg/uL; and
RRF = relative response factor.
NOTE: The above formula is also used to compute the
RRFs for the various internal standards relative to the
recovery standard, 13C12-1,2,3,4-TCDD.
14.2.2

Concentrations of sample components. Figure 5 presents
a schematic for quantisation of PCDDs and PCDFs which
meet the criteria specified in Section 14.1. Calculate
the concentration of PCDD/Fs in sample extracts using
the formula:
y TC
A,. - Qis
X
C

x=

A

IS'

RRF •'

W
AT

• LC

Eq. 14-2

where Cx = the lipid adjusted concentration of PCDD or
PCDF congener in pg/g;
Ax = sum of the integrated ion abundances determined for the PCDD/PCDF in question;
AIS = sum of the integrated ion abundances determined for the labeled PCDD/F used as the
internal quantisation standard for the above
analyte;
QjS = the amount (total pg) of the labeled internal
quantisation standard added to the sample
prior to extraction;
RRF = relative response factor of the above
analyte relative to its labeled internal
quantisation standard determined from the
initial triplicate calibration;
WAT = weight of original adipose tissue sample;
Al
and
LC = percent extractable lipid determined from
Eq. 11-1.
Quantitative data should be classified to indicate the
intensity of the signal response. Suggested qualifiers
include: not detected, NO (signal-to-noise ratio is
less than 2.5); trace, TR (signal-to-noise ratio is
greater than or equal to 2.5 but less than 10); and
positive quantifiable, PQ (signal-to-noise ratio is
greater than or equal to 10.

A-44

�QUANTITATION

HRGC/MS-SIMData

Response
Meets All
Qualitative
Criteria?

Report as Not Detected
Calculate Sample LOD

Response
&gt;2.5t[mes
S/N?

Response
&gt; 10 times
S/N?

Calculate as per Protocol
Report as Trace (tr) Value

Quantitate as per Protocol
Report as Positive Quantifiable Value

Figure 5. Procedure for quantitation of PCDDs and PCDFs
in human adipose tissue.

A-45

�14.2.3

Recovery of internal quantisation standards. Calculate
the recovery of the labeled internal quantisation standards measured in the final extract-using the formula:
QRS
Internal Quant. Std. _
Eq. 14.3
Percent Recovery
~ ARS
RRF 100
where AT&lt;; = sum of the integrated ion abundances deteri:&gt;
mined for the labeled PCDD/PCDF internal
quantisation standard in question;
A

Q

RS

sum of the integrated ion abundances determined for m/z 332 and m/z 334 of 13C121,2,3,4-TCDD (recovery standard);

recovery standard,
RS ~ amount (pg) of the added to the final
13
C12-1,2,3,4-TCDD
extract;

QIS = amount (pg) the labeled internal quantitation standard added to the sample prior to
extraction; and
RRF = relative response factor for the labeled
internal quantitation standard in question
relative to the internal recovery standard.
This value shall be the RRF determined from
the initial calibration.
14.3

Estimated Method Detection Limit
Estimated
where (1)
sponse is
sponse is

method detection limits must be calculated in situations
no response is noted for a specific congener; (2) a renoted but ion ratios are incorrect; and (3) where a requantitated as a trace value.

14.3.1

For samples in which no unlabeled PCDD or PCDF is detected, calculate the estimated minimum detectable concentration. The background area is determined by integrating the ion abundances for the characteristic ions
in the appropriate region and relating the product area
to an estimated concentration that would produce that
product area.
Use the formula:

(2.5)
Eq. 14-4
&lt; A IS&gt;

A-46

(RRF) • (W)

�where C^ = estimated concentration of unlabeled PCDD
or PCDF required to produce AX;
A

= sum of integrated ion abundances or peak
heights for the characteristic ions of the
unlabeled PCDD or PCDF isomer in the same
group of ^ 5 scans used to measure A,s; and

AjS = sum of integrated ion abundances for the
appropriate ions characteristic of the respective internal quantitation standard.
Qjc, RRF, and W retain the definitions previously stated
in Section 14.2. Alternatively, if peak height measurements are used for quantification, measure the estimated
detection limit by the peak height of the noise in the
2,3,7,8-TCDD RT window.
14.3.2

For samples for which a response at the retention time
of a specific PCDD or PCDF congener is noted, but the
quantitative criteria for ion ratios is outside the
acceptable range (Table 7), the estimated detection
level is calculated as given in Eq. 14.3 except the
values are qualified as not detected, ND, and the
concentration is reported in parenthesis.

14.3.3

If a response for a specific PCDD or PCDF congener is
qualified as a trace, TR, value (signal to noise is
greater than or equal to 2.5 but less than 10) the
analyst must also provide an estimated method detection
limit. This is accomplished by using the observed signal to noise on either side of the response and calculating as given in Eq. 14-4.

15. REPORTING AND DOCUMENTATION

All data should be reported on an individual sample basis using the data
report format shown in Figure 6. The analyst is required to maintain
all raw data, calculations, and control charts in a format as to allow a
complete external data review. Suggested data formats for tracing calculationsare provided in Figure 7.

A-47

�Pig* 1 oil

U.S. ENVIRONMENTAL PflOTECTION AGENCY
OFFICE OF TOXIC SUBSTANCES
EXPOSURE EVALUATION DIVISION (TS-7M)
WASHINGTON, DC 20460

NATIONAL HUMAN ADIPOSE TISSUE SURVEY

ANALYSIS REPORT FORM

EPA SAMPLE NUMBER.

ANALYSIS DATE

LAB NUMBER

MS ANALYST

BATCH NUMBER

REPORT DATE

_

REPORTED BY

_

NATIVE
COMPOUNDS

CONCENTRATION

(pg/gLl/

DATA

INTERNAL QUANTITATION
STANDARD

QUALIFIER!/

2.3,7.8-TCDD

1 ,,.!•!, 1

1

2.3,7,8-TCOF

1 . . ... |*l , 1

13

1,2.3,7,8-PeCDO

1 , , . 1*1 , r

1

3C12-2.3,7.8-TCDO
Ci8-2,3,7.8-TCDF

3C12-1.2,3.7,8-P«COD

1,2.3,7,8-PeODF

1 . . . |*)l , 1

13

2.3,4,7.8-PeCDF

1 , . , Ul jlT l

1

&lt;,2.3,4.7,8-HxCDO

1 ...

1

1,2.3,8,7.8-HxCDD

1 ...!•( i 1

1,2.3,7.8.9-HxCDO

1 , i , 1*1 . 1

'3C12-1,2,3,4,8.7,a-HpCDF

1,2.3,4.7.8-HxCDF

1 ...!•), 1

13

1,2.3,8,7,8-HxCDF

1 . . . Ul , 1

'SCu-OODF

1,2.3,7.8.9-HxCDF

1 . . . I.I . 1

2.3.4,8,7,8-HxCDF

1 , i , |«4 , 1

t.2,3,4,8,7,8-HpCDD

1 ...

1,2,3,4,8,7,8-HpCDF

1 , , , 1*1 , 1

1*1 , 1

C12-1.2,3.7,8-PeCDF

3Ct2-1.2.3.6.'.a-H»CDD

3C12-t.2,3,4.7.8-HxCDF

'3012-1.2.3.4,8,7,8^0000

Cia-OCDO

1*1 , 1

1.2.3.4,7.8,9-HpCDF

1 , . . Ul

OCOO

I , . . !•( . 1

. 1

OCOF

1 . . . 1*1 . 1

REMARKS

Jj

Concantratlon reported la based on total extractable lipld (a).

I NO - Not Detected, TR - Traoe. PQ - Positive Quantifiable.
/

Figure 6. Analysis report form.

A-48

SPIKED LEVEL

(P9)

PERCENT (%)
RECOVERY

�RAW DATA SUMMARY FOR DETERMINATION OF 1.2.3.7,8-PeCDD IN HUMAN ADIPOSE TISSUE

Sample
no.

3

Sample
weight
(xx.xx g)

Extractable
lipid
content
(xx.x %)

Analysis
date

Amount
C12-PeCDD
(pg)

13

13

C12-PeCDD
m/z 332

3

&gt; C12-PeCOD
m/z 334

Ion ratio
366/368

1,2,3,7,8PeCDD
m/z 354

Value reported as concentration in extractable lipid.

Figure 7. Example of raw data summary format for the determination of
1,2,3,7,8-PeCDD in human adipose tissue.

1,2,3,7,8
m/2 356

Ion ratio
354/356

1,2,3,7,8PeCDD
cone.
(pg/g)

�</text>
                  </elementText>
                </elementTextContainer>
              </element>
            </elementContainer>
          </elementSet>
        </elementSetContainer>
      </file>
    </fileContainer>
    <collection collectionId="30">
      <elementSetContainer>
        <elementSet elementSetId="1">
          <name>Dublin Core</name>
          <description>The Dublin Core metadata element set is common to all Omeka records, including items, files, and collections. For more information see, http://dublincore.org/documents/dces/.</description>
          <elementContainer>
            <element elementId="50">
              <name>Title</name>
              <description>A name given to the resource</description>
              <elementTextContainer>
                <elementText elementTextId="4687">
                  <text>Alvin L. Young Collection on Agent Orange</text>
                </elementText>
              </elementTextContainer>
            </element>
            <element elementId="41">
              <name>Description</name>
              <description>An account of the resource</description>
              <elementTextContainer>
                <elementText elementTextId="49809">
                  <text>&lt;p style="margin-top: -1em; line-height: 1.2em;"&gt;The Alvin L. Young Collection on Agent Orange comprises 120 linear feet and spans the late 1800s to 2005; however, the bulk of the coverage is from the 1960s to the 1980s and there are many undated items. The collection was donated to Special Collections of the National Agricultural Library in 1985 by Dr. Alvin L. Young (1942- ). Dr. Young developed the collection as he conducted extensive research on the military defoliant Agent Orange. The collection is in good condition and includes letters, memoranda, books, reports, press releases, journal and newspaper clippings, field logs and notebooks, newsletters, maps, booklets and pamphlets, photographs, memorabilia, and audiotapes of an interview with Dr. Young.&lt;/p&gt;&#13;
&lt;p&gt;For more about this collection, &lt;a href="/exhibits/speccoll/exhibits/show/alvin-l--young-collection-on-a"&gt;view the Agent Orange Exhibit.&lt;/a&gt;&lt;/p&gt;</text>
                </elementText>
              </elementTextContainer>
            </element>
          </elementContainer>
        </elementSet>
      </elementSetContainer>
    </collection>
    <itemType itemTypeId="1">
      <name>Text</name>
      <description>A resource consisting primarily of words for reading. Examples include books, letters, dissertations, poems, newspapers, articles, archives of mailing lists. Note that facsimiles or images of texts are still of the genre Text.</description>
      <elementContainer>
        <element elementId="52">
          <name>Box</name>
          <description>The box containing the original item.</description>
          <elementTextContainer>
            <elementText elementTextId="48178">
              <text>197</text>
            </elementText>
          </elementTextContainer>
        </element>
        <element elementId="53">
          <name>Folder</name>
          <description>The folder containing the original item.</description>
          <elementTextContainer>
            <elementText elementTextId="48180">
              <text>5522</text>
            </elementText>
          </elementTextContainer>
        </element>
        <element elementId="54">
          <name>Series</name>
          <description>The series number of the original item.</description>
          <elementTextContainer>
            <elementText elementTextId="48183">
              <text>Series VIII Subseries I</text>
            </elementText>
          </elementTextContainer>
        </element>
      </elementContainer>
    </itemType>
    <elementSetContainer>
      <elementSet elementSetId="1">
        <name>Dublin Core</name>
        <description>The Dublin Core metadata element set is common to all Omeka records, including items, files, and collections. For more information see, http://dublincore.org/documents/dces/.</description>
        <elementContainer>
          <element elementId="39">
            <name>Creator</name>
            <description>An entity primarily responsible for making the resource</description>
            <elementTextContainer>
              <elementText elementTextId="48176">
                <text>Stanley, John S.</text>
              </elementText>
              <elementText elementTextId="48177">
                <text>et al.</text>
              </elementText>
            </elementTextContainer>
          </element>
          <element elementId="41">
            <name>Description</name>
            <description>An account of the resource</description>
            <elementTextContainer>
              <elementText elementTextId="48179">
                <text>&lt;strong&gt;Corporate Author: &lt;/strong&gt;Midwest Research Institute</text>
              </elementText>
            </elementTextContainer>
          </element>
          <element elementId="40">
            <name>Date</name>
            <description>A point or period of time associated with an event in the lifecycle of the resource</description>
            <elementTextContainer>
              <elementText elementTextId="48181">
                <text>1986</text>
              </elementText>
            </elementTextContainer>
          </element>
          <element elementId="50">
            <name>Title</name>
            <description>A name given to the resource</description>
            <elementTextContainer>
              <elementText elementTextId="48182">
                <text>Analysis for Polychlorinated Dibenzo-p-Dioxins and Dibenzofurans in Human Adipose Tissue: Method Evaluation Study: Draft Final Report with attached letter transmitting the report to Alvin L. Young, from Janet C. Remmers, Field Studies Branch, Exposure Eva</text>
              </elementText>
            </elementTextContainer>
          </element>
        </elementContainer>
      </elementSet>
    </elementSetContainer>
    <tagContainer>
      <tag tagId="2">
        <name>ao_seriesVIII</name>
      </tag>
    </tagContainer>
  </item>
  <item itemId="6310" public="1" featured="0">
    <collection collectionId="30">
      <elementSetContainer>
        <elementSet elementSetId="1">
          <name>Dublin Core</name>
          <description>The Dublin Core metadata element set is common to all Omeka records, including items, files, and collections. For more information see, http://dublincore.org/documents/dces/.</description>
          <elementContainer>
            <element elementId="50">
              <name>Title</name>
              <description>A name given to the resource</description>
              <elementTextContainer>
                <elementText elementTextId="4687">
                  <text>Alvin L. Young Collection on Agent Orange</text>
                </elementText>
              </elementTextContainer>
            </element>
            <element elementId="41">
              <name>Description</name>
              <description>An account of the resource</description>
              <elementTextContainer>
                <elementText elementTextId="49809">
                  <text>&lt;p style="margin-top: -1em; line-height: 1.2em;"&gt;The Alvin L. Young Collection on Agent Orange comprises 120 linear feet and spans the late 1800s to 2005; however, the bulk of the coverage is from the 1960s to the 1980s and there are many undated items. The collection was donated to Special Collections of the National Agricultural Library in 1985 by Dr. Alvin L. Young (1942- ). Dr. Young developed the collection as he conducted extensive research on the military defoliant Agent Orange. The collection is in good condition and includes letters, memoranda, books, reports, press releases, journal and newspaper clippings, field logs and notebooks, newsletters, maps, booklets and pamphlets, photographs, memorabilia, and audiotapes of an interview with Dr. Young.&lt;/p&gt;&#13;
&lt;p&gt;For more about this collection, &lt;a href="/exhibits/speccoll/exhibits/show/alvin-l--young-collection-on-a"&gt;view the Agent Orange Exhibit.&lt;/a&gt;&lt;/p&gt;</text>
                </elementText>
              </elementTextContainer>
            </element>
          </elementContainer>
        </elementSet>
      </elementSetContainer>
    </collection>
    <itemType itemTypeId="1">
      <name>Text</name>
      <description>A resource consisting primarily of words for reading. Examples include books, letters, dissertations, poems, newspapers, articles, archives of mailing lists. Note that facsimiles or images of texts are still of the genre Text.</description>
      <elementContainer>
        <element elementId="52">
          <name>Box</name>
          <description>The box containing the original item.</description>
          <elementTextContainer>
            <elementText elementTextId="47082">
              <text>175</text>
            </elementText>
          </elementTextContainer>
        </element>
        <element elementId="53">
          <name>Folder</name>
          <description>The folder containing the original item.</description>
          <elementTextContainer>
            <elementText elementTextId="47083">
              <text>5165</text>
            </elementText>
          </elementTextContainer>
        </element>
        <element elementId="54">
          <name>Series</name>
          <description>The series number of the original item.</description>
          <elementTextContainer>
            <elementText elementTextId="47085">
              <text>Series VII</text>
            </elementText>
          </elementTextContainer>
        </element>
      </elementContainer>
    </itemType>
    <elementSetContainer>
      <elementSet elementSetId="1">
        <name>Dublin Core</name>
        <description>The Dublin Core metadata element set is common to all Omeka records, including items, files, and collections. For more information see, http://dublincore.org/documents/dces/.</description>
        <elementContainer>
          <element elementId="39">
            <name>Creator</name>
            <description>An entity primarily responsible for making the resource</description>
            <elementTextContainer>
              <elementText elementTextId="47079">
                <text>Schecter, Arnold J.</text>
              </elementText>
              <elementText elementTextId="47080">
                <text>John J. Ryan</text>
              </elementText>
              <elementText elementTextId="47081">
                <text>et al.</text>
              </elementText>
            </elementTextContainer>
          </element>
          <element elementId="50">
            <name>Title</name>
            <description>A name given to the resource</description>
            <elementTextContainer>
              <elementText elementTextId="47084">
                <text>Chlorinated Dibenzodioxins and Dibenzofurans in Human Adipose Tissue from Exposed and Control Patients</text>
              </elementText>
            </elementTextContainer>
          </element>
        </elementContainer>
      </elementSet>
    </elementSetContainer>
  </item>
  <item itemId="6308" public="1" featured="0">
    <collection collectionId="30">
      <elementSetContainer>
        <elementSet elementSetId="1">
          <name>Dublin Core</name>
          <description>The Dublin Core metadata element set is common to all Omeka records, including items, files, and collections. For more information see, http://dublincore.org/documents/dces/.</description>
          <elementContainer>
            <element elementId="50">
              <name>Title</name>
              <description>A name given to the resource</description>
              <elementTextContainer>
                <elementText elementTextId="4687">
                  <text>Alvin L. Young Collection on Agent Orange</text>
                </elementText>
              </elementTextContainer>
            </element>
            <element elementId="41">
              <name>Description</name>
              <description>An account of the resource</description>
              <elementTextContainer>
                <elementText elementTextId="49809">
                  <text>&lt;p style="margin-top: -1em; line-height: 1.2em;"&gt;The Alvin L. Young Collection on Agent Orange comprises 120 linear feet and spans the late 1800s to 2005; however, the bulk of the coverage is from the 1960s to the 1980s and there are many undated items. The collection was donated to Special Collections of the National Agricultural Library in 1985 by Dr. Alvin L. Young (1942- ). Dr. Young developed the collection as he conducted extensive research on the military defoliant Agent Orange. The collection is in good condition and includes letters, memoranda, books, reports, press releases, journal and newspaper clippings, field logs and notebooks, newsletters, maps, booklets and pamphlets, photographs, memorabilia, and audiotapes of an interview with Dr. Young.&lt;/p&gt;&#13;
&lt;p&gt;For more about this collection, &lt;a href="/exhibits/speccoll/exhibits/show/alvin-l--young-collection-on-a"&gt;view the Agent Orange Exhibit.&lt;/a&gt;&lt;/p&gt;</text>
                </elementText>
              </elementTextContainer>
            </element>
          </elementContainer>
        </elementSet>
      </elementSetContainer>
    </collection>
    <itemType itemTypeId="1">
      <name>Text</name>
      <description>A resource consisting primarily of words for reading. Examples include books, letters, dissertations, poems, newspapers, articles, archives of mailing lists. Note that facsimiles or images of texts are still of the genre Text.</description>
      <elementContainer>
        <element elementId="52">
          <name>Box</name>
          <description>The box containing the original item.</description>
          <elementTextContainer>
            <elementText elementTextId="47068">
              <text>175</text>
            </elementText>
          </elementTextContainer>
        </element>
        <element elementId="53">
          <name>Folder</name>
          <description>The folder containing the original item.</description>
          <elementTextContainer>
            <elementText elementTextId="47069">
              <text>5163</text>
            </elementText>
          </elementTextContainer>
        </element>
        <element elementId="54">
          <name>Series</name>
          <description>The series number of the original item.</description>
          <elementTextContainer>
            <elementText elementTextId="47071">
              <text>Series VII</text>
            </elementText>
          </elementTextContainer>
        </element>
      </elementContainer>
    </itemType>
    <elementSetContainer>
      <elementSet elementSetId="1">
        <name>Dublin Core</name>
        <description>The Dublin Core metadata element set is common to all Omeka records, including items, files, and collections. For more information see, http://dublincore.org/documents/dces/.</description>
        <elementContainer>
          <element elementId="39">
            <name>Creator</name>
            <description>An entity primarily responsible for making the resource</description>
            <elementTextContainer>
              <elementText elementTextId="47066">
                <text>Weerasinghe, N.C.A.</text>
              </elementText>
              <elementText elementTextId="47067">
                <text>et al.</text>
              </elementText>
            </elementTextContainer>
          </element>
          <element elementId="50">
            <name>Title</name>
            <description>A name given to the resource</description>
            <elementTextContainer>
              <elementText elementTextId="47070">
                <text>Levels of 2,3,7,8- Tetrachlorodibenzo -p- Dioxin (2,3,7,8 - TCDD) in Adipose Tissue of U.S. Vietnam Veterans Seeking Medical Assistance</text>
              </elementText>
            </elementTextContainer>
          </element>
        </elementContainer>
      </elementSet>
    </elementSetContainer>
  </item>
  <item itemId="6297" public="1" featured="0">
    <collection collectionId="30">
      <elementSetContainer>
        <elementSet elementSetId="1">
          <name>Dublin Core</name>
          <description>The Dublin Core metadata element set is common to all Omeka records, including items, files, and collections. For more information see, http://dublincore.org/documents/dces/.</description>
          <elementContainer>
            <element elementId="50">
              <name>Title</name>
              <description>A name given to the resource</description>
              <elementTextContainer>
                <elementText elementTextId="4687">
                  <text>Alvin L. Young Collection on Agent Orange</text>
                </elementText>
              </elementTextContainer>
            </element>
            <element elementId="41">
              <name>Description</name>
              <description>An account of the resource</description>
              <elementTextContainer>
                <elementText elementTextId="49809">
                  <text>&lt;p style="margin-top: -1em; line-height: 1.2em;"&gt;The Alvin L. Young Collection on Agent Orange comprises 120 linear feet and spans the late 1800s to 2005; however, the bulk of the coverage is from the 1960s to the 1980s and there are many undated items. The collection was donated to Special Collections of the National Agricultural Library in 1985 by Dr. Alvin L. Young (1942- ). Dr. Young developed the collection as he conducted extensive research on the military defoliant Agent Orange. The collection is in good condition and includes letters, memoranda, books, reports, press releases, journal and newspaper clippings, field logs and notebooks, newsletters, maps, booklets and pamphlets, photographs, memorabilia, and audiotapes of an interview with Dr. Young.&lt;/p&gt;&#13;
&lt;p&gt;For more about this collection, &lt;a href="/exhibits/speccoll/exhibits/show/alvin-l--young-collection-on-a"&gt;view the Agent Orange Exhibit.&lt;/a&gt;&lt;/p&gt;</text>
                </elementText>
              </elementTextContainer>
            </element>
          </elementContainer>
        </elementSet>
      </elementSetContainer>
    </collection>
    <itemType itemTypeId="1">
      <name>Text</name>
      <description>A resource consisting primarily of words for reading. Examples include books, letters, dissertations, poems, newspapers, articles, archives of mailing lists. Note that facsimiles or images of texts are still of the genre Text.</description>
      <elementContainer>
        <element elementId="52">
          <name>Box</name>
          <description>The box containing the original item.</description>
          <elementTextContainer>
            <elementText elementTextId="46997">
              <text>175</text>
            </elementText>
          </elementTextContainer>
        </element>
        <element elementId="53">
          <name>Folder</name>
          <description>The folder containing the original item.</description>
          <elementTextContainer>
            <elementText elementTextId="46998">
              <text>5154</text>
            </elementText>
          </elementTextContainer>
        </element>
        <element elementId="54">
          <name>Series</name>
          <description>The series number of the original item.</description>
          <elementTextContainer>
            <elementText elementTextId="47000">
              <text>Series VII</text>
            </elementText>
          </elementTextContainer>
        </element>
      </elementContainer>
    </itemType>
    <elementSetContainer>
      <elementSet elementSetId="1">
        <name>Dublin Core</name>
        <description>The Dublin Core metadata element set is common to all Omeka records, including items, files, and collections. For more information see, http://dublincore.org/documents/dces/.</description>
        <elementContainer>
          <element elementId="39">
            <name>Creator</name>
            <description>An entity primarily responsible for making the resource</description>
            <elementTextContainer>
              <elementText elementTextId="46995">
                <text>Rappe, Christoffer</text>
              </elementText>
              <elementText elementTextId="46996">
                <text>et al.</text>
              </elementText>
            </elementTextContainer>
          </element>
          <element elementId="50">
            <name>Title</name>
            <description>A name given to the resource</description>
            <elementTextContainer>
              <elementText elementTextId="46999">
                <text>Identification of 2,3,7,8 -Substituted Ploychlorinated Dioxins (PCDDs) and Dibenzofurans (PCDFs) in Environmental and Human Samples</text>
              </elementText>
            </elementTextContainer>
          </element>
        </elementContainer>
      </elementSet>
    </elementSetContainer>
  </item>
  <item itemId="6134" public="1" featured="0">
    <collection collectionId="30">
      <elementSetContainer>
        <elementSet elementSetId="1">
          <name>Dublin Core</name>
          <description>The Dublin Core metadata element set is common to all Omeka records, including items, files, and collections. For more information see, http://dublincore.org/documents/dces/.</description>
          <elementContainer>
            <element elementId="50">
              <name>Title</name>
              <description>A name given to the resource</description>
              <elementTextContainer>
                <elementText elementTextId="4687">
                  <text>Alvin L. Young Collection on Agent Orange</text>
                </elementText>
              </elementTextContainer>
            </element>
            <element elementId="41">
              <name>Description</name>
              <description>An account of the resource</description>
              <elementTextContainer>
                <elementText elementTextId="49809">
                  <text>&lt;p style="margin-top: -1em; line-height: 1.2em;"&gt;The Alvin L. Young Collection on Agent Orange comprises 120 linear feet and spans the late 1800s to 2005; however, the bulk of the coverage is from the 1960s to the 1980s and there are many undated items. The collection was donated to Special Collections of the National Agricultural Library in 1985 by Dr. Alvin L. Young (1942- ). Dr. Young developed the collection as he conducted extensive research on the military defoliant Agent Orange. The collection is in good condition and includes letters, memoranda, books, reports, press releases, journal and newspaper clippings, field logs and notebooks, newsletters, maps, booklets and pamphlets, photographs, memorabilia, and audiotapes of an interview with Dr. Young.&lt;/p&gt;&#13;
&lt;p&gt;For more about this collection, &lt;a href="/exhibits/speccoll/exhibits/show/alvin-l--young-collection-on-a"&gt;view the Agent Orange Exhibit.&lt;/a&gt;&lt;/p&gt;</text>
                </elementText>
              </elementTextContainer>
            </element>
          </elementContainer>
        </elementSet>
      </elementSetContainer>
    </collection>
    <itemType itemTypeId="1">
      <name>Text</name>
      <description>A resource consisting primarily of words for reading. Examples include books, letters, dissertations, poems, newspapers, articles, archives of mailing lists. Note that facsimiles or images of texts are still of the genre Text.</description>
      <elementContainer>
        <element elementId="52">
          <name>Box</name>
          <description>The box containing the original item.</description>
          <elementTextContainer>
            <elementText elementTextId="46017">
              <text>168</text>
            </elementText>
          </elementTextContainer>
        </element>
        <element elementId="53">
          <name>Folder</name>
          <description>The folder containing the original item.</description>
          <elementTextContainer>
            <elementText elementTextId="46019">
              <text>5009</text>
            </elementText>
          </elementTextContainer>
        </element>
        <element elementId="54">
          <name>Series</name>
          <description>The series number of the original item.</description>
          <elementTextContainer>
            <elementText elementTextId="46022">
              <text>Series VII</text>
            </elementText>
          </elementTextContainer>
        </element>
      </elementContainer>
    </itemType>
    <elementSetContainer>
      <elementSet elementSetId="1">
        <name>Dublin Core</name>
        <description>The Dublin Core metadata element set is common to all Omeka records, including items, files, and collections. For more information see, http://dublincore.org/documents/dces/.</description>
        <elementContainer>
          <element elementId="39">
            <name>Creator</name>
            <description>An entity primarily responsible for making the resource</description>
            <elementTextContainer>
              <elementText elementTextId="46015">
                <text>Ghassemi, Masood</text>
              </elementText>
              <elementText elementTextId="46016">
                <text>et al.</text>
              </elementText>
            </elementTextContainer>
          </element>
          <element elementId="41">
            <name>Description</name>
            <description>An account of the resource</description>
            <elementTextContainer>
              <elementText elementTextId="46018">
                <text>&lt;strong&gt;Corporate Author: &lt;/strong&gt;TRW Environmental Division, Redondo Beach, CA</text>
              </elementText>
            </elementTextContainer>
          </element>
          <element elementId="40">
            <name>Date</name>
            <description>A point or period of time associated with an event in the lifecycle of the resource</description>
            <elementTextContainer>
              <elementText elementTextId="46020">
                <text>1981-12-01</text>
              </elementText>
            </elementTextContainer>
          </element>
          <element elementId="50">
            <name>Title</name>
            <description>A name given to the resource</description>
            <elementTextContainer>
              <elementText elementTextId="46021">
                <text>Environmental Fates and Impacts of Major Forest Use Pesticides</text>
              </elementText>
            </elementTextContainer>
          </element>
        </elementContainer>
      </elementSet>
    </elementSetContainer>
  </item>
  <item itemId="5528" public="1" featured="0">
    <collection collectionId="30">
      <elementSetContainer>
        <elementSet elementSetId="1">
          <name>Dublin Core</name>
          <description>The Dublin Core metadata element set is common to all Omeka records, including items, files, and collections. For more information see, http://dublincore.org/documents/dces/.</description>
          <elementContainer>
            <element elementId="50">
              <name>Title</name>
              <description>A name given to the resource</description>
              <elementTextContainer>
                <elementText elementTextId="4687">
                  <text>Alvin L. Young Collection on Agent Orange</text>
                </elementText>
              </elementTextContainer>
            </element>
            <element elementId="41">
              <name>Description</name>
              <description>An account of the resource</description>
              <elementTextContainer>
                <elementText elementTextId="49809">
                  <text>&lt;p style="margin-top: -1em; line-height: 1.2em;"&gt;The Alvin L. Young Collection on Agent Orange comprises 120 linear feet and spans the late 1800s to 2005; however, the bulk of the coverage is from the 1960s to the 1980s and there are many undated items. The collection was donated to Special Collections of the National Agricultural Library in 1985 by Dr. Alvin L. Young (1942- ). Dr. Young developed the collection as he conducted extensive research on the military defoliant Agent Orange. The collection is in good condition and includes letters, memoranda, books, reports, press releases, journal and newspaper clippings, field logs and notebooks, newsletters, maps, booklets and pamphlets, photographs, memorabilia, and audiotapes of an interview with Dr. Young.&lt;/p&gt;&#13;
&lt;p&gt;For more about this collection, &lt;a href="/exhibits/speccoll/exhibits/show/alvin-l--young-collection-on-a"&gt;view the Agent Orange Exhibit.&lt;/a&gt;&lt;/p&gt;</text>
                </elementText>
              </elementTextContainer>
            </element>
          </elementContainer>
        </elementSet>
      </elementSetContainer>
    </collection>
    <itemType itemTypeId="1">
      <name>Text</name>
      <description>A resource consisting primarily of words for reading. Examples include books, letters, dissertations, poems, newspapers, articles, archives of mailing lists. Note that facsimiles or images of texts are still of the genre Text.</description>
      <elementContainer>
        <element elementId="52">
          <name>Box</name>
          <description>The box containing the original item.</description>
          <elementTextContainer>
            <elementText elementTextId="41846">
              <text>154</text>
            </elementText>
          </elementTextContainer>
        </element>
        <element elementId="53">
          <name>Folder</name>
          <description>The folder containing the original item.</description>
          <elementTextContainer>
            <elementText elementTextId="41847">
              <text>4574</text>
            </elementText>
          </elementTextContainer>
        </element>
        <element elementId="54">
          <name>Series</name>
          <description>The series number of the original item.</description>
          <elementTextContainer>
            <elementText elementTextId="41851">
              <text>Series VII</text>
            </elementText>
          </elementTextContainer>
        </element>
      </elementContainer>
    </itemType>
    <elementSetContainer>
      <elementSet elementSetId="1">
        <name>Dublin Core</name>
        <description>The Dublin Core metadata element set is common to all Omeka records, including items, files, and collections. For more information see, http://dublincore.org/documents/dces/.</description>
        <elementContainer>
          <element elementId="39">
            <name>Creator</name>
            <description>An entity primarily responsible for making the resource</description>
            <elementTextContainer>
              <elementText elementTextId="41844">
                <text>Menges, Robert W.</text>
              </elementText>
              <elementText elementTextId="41845">
                <text>et al.</text>
              </elementText>
            </elementTextContainer>
          </element>
          <element elementId="48">
            <name>Source</name>
            <description>A related resource from which the described resource is derived</description>
            <elementTextContainer>
              <elementText elementTextId="41848">
                <text>Veterinary Medicine</text>
              </elementText>
            </elementTextContainer>
          </element>
          <element elementId="40">
            <name>Date</name>
            <description>A point or period of time associated with an event in the lifecycle of the resource</description>
            <elementTextContainer>
              <elementText elementTextId="41849">
                <text>1970-06-01</text>
              </elementText>
            </elementTextContainer>
          </element>
          <element elementId="50">
            <name>Title</name>
            <description>A name given to the resource</description>
            <elementTextContainer>
              <elementText elementTextId="41850">
                <text>Arsanilic Acid Blindness in Pigs</text>
              </elementText>
            </elementTextContainer>
          </element>
        </elementContainer>
      </elementSet>
    </elementSetContainer>
  </item>
  <item itemId="5290" public="1" featured="0">
    <collection collectionId="30">
      <elementSetContainer>
        <elementSet elementSetId="1">
          <name>Dublin Core</name>
          <description>The Dublin Core metadata element set is common to all Omeka records, including items, files, and collections. For more information see, http://dublincore.org/documents/dces/.</description>
          <elementContainer>
            <element elementId="50">
              <name>Title</name>
              <description>A name given to the resource</description>
              <elementTextContainer>
                <elementText elementTextId="4687">
                  <text>Alvin L. Young Collection on Agent Orange</text>
                </elementText>
              </elementTextContainer>
            </element>
            <element elementId="41">
              <name>Description</name>
              <description>An account of the resource</description>
              <elementTextContainer>
                <elementText elementTextId="49809">
                  <text>&lt;p style="margin-top: -1em; line-height: 1.2em;"&gt;The Alvin L. Young Collection on Agent Orange comprises 120 linear feet and spans the late 1800s to 2005; however, the bulk of the coverage is from the 1960s to the 1980s and there are many undated items. The collection was donated to Special Collections of the National Agricultural Library in 1985 by Dr. Alvin L. Young (1942- ). Dr. Young developed the collection as he conducted extensive research on the military defoliant Agent Orange. The collection is in good condition and includes letters, memoranda, books, reports, press releases, journal and newspaper clippings, field logs and notebooks, newsletters, maps, booklets and pamphlets, photographs, memorabilia, and audiotapes of an interview with Dr. Young.&lt;/p&gt;&#13;
&lt;p&gt;For more about this collection, &lt;a href="/exhibits/speccoll/exhibits/show/alvin-l--young-collection-on-a"&gt;view the Agent Orange Exhibit.&lt;/a&gt;&lt;/p&gt;</text>
                </elementText>
              </elementTextContainer>
            </element>
          </elementContainer>
        </elementSet>
      </elementSetContainer>
    </collection>
    <itemType itemTypeId="1">
      <name>Text</name>
      <description>A resource consisting primarily of words for reading. Examples include books, letters, dissertations, poems, newspapers, articles, archives of mailing lists. Note that facsimiles or images of texts are still of the genre Text.</description>
      <elementContainer>
        <element elementId="52">
          <name>Box</name>
          <description>The box containing the original item.</description>
          <elementTextContainer>
            <elementText elementTextId="39955">
              <text>150</text>
            </elementText>
          </elementTextContainer>
        </element>
        <element elementId="53">
          <name>Folder</name>
          <description>The folder containing the original item.</description>
          <elementTextContainer>
            <elementText elementTextId="39957">
              <text>4355</text>
            </elementText>
          </elementTextContainer>
        </element>
        <element elementId="54">
          <name>Series</name>
          <description>The series number of the original item.</description>
          <elementTextContainer>
            <elementText elementTextId="39961">
              <text>Series VII</text>
            </elementText>
          </elementTextContainer>
        </element>
      </elementContainer>
    </itemType>
    <elementSetContainer>
      <elementSet elementSetId="1">
        <name>Dublin Core</name>
        <description>The Dublin Core metadata element set is common to all Omeka records, including items, files, and collections. For more information see, http://dublincore.org/documents/dces/.</description>
        <elementContainer>
          <element elementId="39">
            <name>Creator</name>
            <description>An entity primarily responsible for making the resource</description>
            <elementTextContainer>
              <elementText elementTextId="39953">
                <text>Levander, Orville A.</text>
              </elementText>
              <elementText elementTextId="39954">
                <text>et al.</text>
              </elementText>
            </elementTextContainer>
          </element>
          <element elementId="41">
            <name>Description</name>
            <description>An account of the resource</description>
            <elementTextContainer>
              <elementText elementTextId="39956">
                <text>&lt;strong&gt;Corporate Author: &lt;/strong&gt;Committee on Medical and Biologic Effects of Environmental Pollutants</text>
              </elementText>
            </elementTextContainer>
          </element>
          <element elementId="48">
            <name>Source</name>
            <description>A related resource from which the described resource is derived</description>
            <elementTextContainer>
              <elementText elementTextId="39958">
                <text>Arsenic</text>
              </elementText>
            </elementTextContainer>
          </element>
          <element elementId="40">
            <name>Date</name>
            <description>A point or period of time associated with an event in the lifecycle of the resource</description>
            <elementTextContainer>
              <elementText elementTextId="39959">
                <text>1977</text>
              </elementText>
            </elementTextContainer>
          </element>
          <element elementId="50">
            <name>Title</name>
            <description>A name given to the resource</description>
            <elementTextContainer>
              <elementText elementTextId="39960">
                <text>Chapter 6: Biologic Effects of Arsenic on Man</text>
              </elementText>
            </elementTextContainer>
          </element>
        </elementContainer>
      </elementSet>
    </elementSetContainer>
  </item>
  <item itemId="5102" public="1" featured="0">
    <collection collectionId="30">
      <elementSetContainer>
        <elementSet elementSetId="1">
          <name>Dublin Core</name>
          <description>The Dublin Core metadata element set is common to all Omeka records, including items, files, and collections. For more information see, http://dublincore.org/documents/dces/.</description>
          <elementContainer>
            <element elementId="50">
              <name>Title</name>
              <description>A name given to the resource</description>
              <elementTextContainer>
                <elementText elementTextId="4687">
                  <text>Alvin L. Young Collection on Agent Orange</text>
                </elementText>
              </elementTextContainer>
            </element>
            <element elementId="41">
              <name>Description</name>
              <description>An account of the resource</description>
              <elementTextContainer>
                <elementText elementTextId="49809">
                  <text>&lt;p style="margin-top: -1em; line-height: 1.2em;"&gt;The Alvin L. Young Collection on Agent Orange comprises 120 linear feet and spans the late 1800s to 2005; however, the bulk of the coverage is from the 1960s to the 1980s and there are many undated items. The collection was donated to Special Collections of the National Agricultural Library in 1985 by Dr. Alvin L. Young (1942- ). Dr. Young developed the collection as he conducted extensive research on the military defoliant Agent Orange. The collection is in good condition and includes letters, memoranda, books, reports, press releases, journal and newspaper clippings, field logs and notebooks, newsletters, maps, booklets and pamphlets, photographs, memorabilia, and audiotapes of an interview with Dr. Young.&lt;/p&gt;&#13;
&lt;p&gt;For more about this collection, &lt;a href="/exhibits/speccoll/exhibits/show/alvin-l--young-collection-on-a"&gt;view the Agent Orange Exhibit.&lt;/a&gt;&lt;/p&gt;</text>
                </elementText>
              </elementTextContainer>
            </element>
          </elementContainer>
        </elementSet>
      </elementSetContainer>
    </collection>
    <itemType itemTypeId="1">
      <name>Text</name>
      <description>A resource consisting primarily of words for reading. Examples include books, letters, dissertations, poems, newspapers, articles, archives of mailing lists. Note that facsimiles or images of texts are still of the genre Text.</description>
      <elementContainer>
        <element elementId="52">
          <name>Box</name>
          <description>The box containing the original item.</description>
          <elementTextContainer>
            <elementText elementTextId="38586">
              <text>144</text>
            </elementText>
          </elementTextContainer>
        </element>
        <element elementId="53">
          <name>Folder</name>
          <description>The folder containing the original item.</description>
          <elementTextContainer>
            <elementText elementTextId="38587">
              <text>4146</text>
            </elementText>
          </elementTextContainer>
        </element>
        <element elementId="54">
          <name>Series</name>
          <description>The series number of the original item.</description>
          <elementTextContainer>
            <elementText elementTextId="38590">
              <text>Series VI Subseries III</text>
            </elementText>
          </elementTextContainer>
        </element>
      </elementContainer>
    </itemType>
    <elementSetContainer>
      <elementSet elementSetId="1">
        <name>Dublin Core</name>
        <description>The Dublin Core metadata element set is common to all Omeka records, including items, files, and collections. For more information see, http://dublincore.org/documents/dces/.</description>
        <elementContainer>
          <element elementId="39">
            <name>Creator</name>
            <description>An entity primarily responsible for making the resource</description>
            <elementTextContainer>
              <elementText elementTextId="38583">
                <text>Facchetti, S.</text>
              </elementText>
              <elementText elementTextId="38584">
                <text>F. Geiss</text>
              </elementText>
              <elementText elementTextId="38585">
                <text>et al.</text>
              </elementText>
            </elementTextContainer>
          </element>
          <element elementId="40">
            <name>Date</name>
            <description>A point or period of time associated with an event in the lifecycle of the resource</description>
            <elementTextContainer>
              <elementText elementTextId="38588">
                <text>1982-07-01</text>
              </elementText>
            </elementTextContainer>
          </element>
          <element elementId="50">
            <name>Title</name>
            <description>A name given to the resource</description>
            <elementTextContainer>
              <elementText elementTextId="38589">
                <text>Isotopic Lead Experiment: Status Report</text>
              </elementText>
            </elementTextContainer>
          </element>
        </elementContainer>
      </elementSet>
    </elementSetContainer>
  </item>
  <item itemId="4616" public="1" featured="0">
    <collection collectionId="30">
      <elementSetContainer>
        <elementSet elementSetId="1">
          <name>Dublin Core</name>
          <description>The Dublin Core metadata element set is common to all Omeka records, including items, files, and collections. For more information see, http://dublincore.org/documents/dces/.</description>
          <elementContainer>
            <element elementId="50">
              <name>Title</name>
              <description>A name given to the resource</description>
              <elementTextContainer>
                <elementText elementTextId="4687">
                  <text>Alvin L. Young Collection on Agent Orange</text>
                </elementText>
              </elementTextContainer>
            </element>
            <element elementId="41">
              <name>Description</name>
              <description>An account of the resource</description>
              <elementTextContainer>
                <elementText elementTextId="49809">
                  <text>&lt;p style="margin-top: -1em; line-height: 1.2em;"&gt;The Alvin L. Young Collection on Agent Orange comprises 120 linear feet and spans the late 1800s to 2005; however, the bulk of the coverage is from the 1960s to the 1980s and there are many undated items. The collection was donated to Special Collections of the National Agricultural Library in 1985 by Dr. Alvin L. Young (1942- ). Dr. Young developed the collection as he conducted extensive research on the military defoliant Agent Orange. The collection is in good condition and includes letters, memoranda, books, reports, press releases, journal and newspaper clippings, field logs and notebooks, newsletters, maps, booklets and pamphlets, photographs, memorabilia, and audiotapes of an interview with Dr. Young.&lt;/p&gt;&#13;
&lt;p&gt;For more about this collection, &lt;a href="/exhibits/speccoll/exhibits/show/alvin-l--young-collection-on-a"&gt;view the Agent Orange Exhibit.&lt;/a&gt;&lt;/p&gt;</text>
                </elementText>
              </elementTextContainer>
            </element>
          </elementContainer>
        </elementSet>
      </elementSetContainer>
    </collection>
    <itemType itemTypeId="1">
      <name>Text</name>
      <description>A resource consisting primarily of words for reading. Examples include books, letters, dissertations, poems, newspapers, articles, archives of mailing lists. Note that facsimiles or images of texts are still of the genre Text.</description>
      <elementContainer>
        <element elementId="52">
          <name>Box</name>
          <description>The box containing the original item.</description>
          <elementTextContainer>
            <elementText elementTextId="35274">
              <text>129</text>
            </elementText>
          </elementTextContainer>
        </element>
        <element elementId="53">
          <name>Folder</name>
          <description>The folder containing the original item.</description>
          <elementTextContainer>
            <elementText elementTextId="35275">
              <text>3653</text>
            </elementText>
          </elementTextContainer>
        </element>
        <element elementId="54">
          <name>Series</name>
          <description>The series number of the original item.</description>
          <elementTextContainer>
            <elementText elementTextId="35279">
              <text>Series VI Subseries III</text>
            </elementText>
          </elementTextContainer>
        </element>
      </elementContainer>
    </itemType>
    <elementSetContainer>
      <elementSet elementSetId="1">
        <name>Dublin Core</name>
        <description>The Dublin Core metadata element set is common to all Omeka records, including items, files, and collections. For more information see, http://dublincore.org/documents/dces/.</description>
        <elementContainer>
          <element elementId="39">
            <name>Creator</name>
            <description>An entity primarily responsible for making the resource</description>
            <elementTextContainer>
              <elementText elementTextId="35272">
                <text>Hluchan, E.</text>
              </elementText>
              <elementText elementTextId="35273">
                <text>et al.</text>
              </elementText>
            </elementTextContainer>
          </element>
          <element elementId="48">
            <name>Source</name>
            <description>A related resource from which the described resource is derived</description>
            <elementTextContainer>
              <elementText elementTextId="35276">
                <text>Ceskoslovenska Hygiena</text>
              </elementText>
            </elementTextContainer>
          </element>
          <element elementId="40">
            <name>Date</name>
            <description>A point or period of time associated with an event in the lifecycle of the resource</description>
            <elementTextContainer>
              <elementText elementTextId="35277">
                <text>1968</text>
              </elementText>
            </elementTextContainer>
          </element>
          <element elementId="50">
            <name>Title</name>
            <description>A name given to the resource</description>
            <elementTextContainer>
              <elementText elementTextId="35278">
                <text>Presence of Arsenic Compounds in the Surroundings of an Aluminium Plant</text>
              </elementText>
            </elementTextContainer>
          </element>
        </elementContainer>
      </elementSet>
    </elementSetContainer>
  </item>
  <item itemId="4211" public="1" featured="0">
    <collection collectionId="30">
      <elementSetContainer>
        <elementSet elementSetId="1">
          <name>Dublin Core</name>
          <description>The Dublin Core metadata element set is common to all Omeka records, including items, files, and collections. For more information see, http://dublincore.org/documents/dces/.</description>
          <elementContainer>
            <element elementId="50">
              <name>Title</name>
              <description>A name given to the resource</description>
              <elementTextContainer>
                <elementText elementTextId="4687">
                  <text>Alvin L. Young Collection on Agent Orange</text>
                </elementText>
              </elementTextContainer>
            </element>
            <element elementId="41">
              <name>Description</name>
              <description>An account of the resource</description>
              <elementTextContainer>
                <elementText elementTextId="49809">
                  <text>&lt;p style="margin-top: -1em; line-height: 1.2em;"&gt;The Alvin L. Young Collection on Agent Orange comprises 120 linear feet and spans the late 1800s to 2005; however, the bulk of the coverage is from the 1960s to the 1980s and there are many undated items. The collection was donated to Special Collections of the National Agricultural Library in 1985 by Dr. Alvin L. Young (1942- ). Dr. Young developed the collection as he conducted extensive research on the military defoliant Agent Orange. The collection is in good condition and includes letters, memoranda, books, reports, press releases, journal and newspaper clippings, field logs and notebooks, newsletters, maps, booklets and pamphlets, photographs, memorabilia, and audiotapes of an interview with Dr. Young.&lt;/p&gt;&#13;
&lt;p&gt;For more about this collection, &lt;a href="/exhibits/speccoll/exhibits/show/alvin-l--young-collection-on-a"&gt;view the Agent Orange Exhibit.&lt;/a&gt;&lt;/p&gt;</text>
                </elementText>
              </elementTextContainer>
            </element>
          </elementContainer>
        </elementSet>
      </elementSetContainer>
    </collection>
    <itemType itemTypeId="1">
      <name>Text</name>
      <description>A resource consisting primarily of words for reading. Examples include books, letters, dissertations, poems, newspapers, articles, archives of mailing lists. Note that facsimiles or images of texts are still of the genre Text.</description>
      <elementContainer>
        <element elementId="52">
          <name>Box</name>
          <description>The box containing the original item.</description>
          <elementTextContainer>
            <elementText elementTextId="31985">
              <text>120</text>
            </elementText>
          </elementTextContainer>
        </element>
        <element elementId="53">
          <name>Folder</name>
          <description>The folder containing the original item.</description>
          <elementTextContainer>
            <elementText elementTextId="31986">
              <text>3246</text>
            </elementText>
          </elementTextContainer>
        </element>
        <element elementId="54">
          <name>Series</name>
          <description>The series number of the original item.</description>
          <elementTextContainer>
            <elementText elementTextId="31990">
              <text>Series VI Subseries II</text>
            </elementText>
          </elementTextContainer>
        </element>
      </elementContainer>
    </itemType>
    <elementSetContainer>
      <elementSet elementSetId="1">
        <name>Dublin Core</name>
        <description>The Dublin Core metadata element set is common to all Omeka records, including items, files, and collections. For more information see, http://dublincore.org/documents/dces/.</description>
        <elementContainer>
          <element elementId="39">
            <name>Creator</name>
            <description>An entity primarily responsible for making the resource</description>
            <elementTextContainer>
              <elementText elementTextId="31983">
                <text>di Domenico, A.</text>
              </elementText>
              <elementText elementTextId="31984">
                <text>et al.</text>
              </elementText>
            </elementTextContainer>
          </element>
          <element elementId="48">
            <name>Source</name>
            <description>A related resource from which the described resource is derived</description>
            <elementTextContainer>
              <elementText elementTextId="31987">
                <text>Analytical Chemistry</text>
              </elementText>
            </elementTextContainer>
          </element>
          <element elementId="40">
            <name>Date</name>
            <description>A point or period of time associated with an event in the lifecycle of the resource</description>
            <elementTextContainer>
              <elementText elementTextId="31988">
                <text>1979-05-01</text>
              </elementText>
            </elementTextContainer>
          </element>
          <element elementId="50">
            <name>Title</name>
            <description>A name given to the resource</description>
            <elementTextContainer>
              <elementText elementTextId="31989">
                <text>Analytical Techniques for 2,3,7,8 -Tetrachlorodibenzo -p- dioxin Detection in Environmental Samples after the Industrial Accident at Seveso</text>
              </elementText>
            </elementTextContainer>
          </element>
        </elementContainer>
      </elementSet>
    </elementSetContainer>
  </item>
  <item itemId="4165" public="1" featured="0">
    <collection collectionId="30">
      <elementSetContainer>
        <elementSet elementSetId="1">
          <name>Dublin Core</name>
          <description>The Dublin Core metadata element set is common to all Omeka records, including items, files, and collections. For more information see, http://dublincore.org/documents/dces/.</description>
          <elementContainer>
            <element elementId="50">
              <name>Title</name>
              <description>A name given to the resource</description>
              <elementTextContainer>
                <elementText elementTextId="4687">
                  <text>Alvin L. Young Collection on Agent Orange</text>
                </elementText>
              </elementTextContainer>
            </element>
            <element elementId="41">
              <name>Description</name>
              <description>An account of the resource</description>
              <elementTextContainer>
                <elementText elementTextId="49809">
                  <text>&lt;p style="margin-top: -1em; line-height: 1.2em;"&gt;The Alvin L. Young Collection on Agent Orange comprises 120 linear feet and spans the late 1800s to 2005; however, the bulk of the coverage is from the 1960s to the 1980s and there are many undated items. The collection was donated to Special Collections of the National Agricultural Library in 1985 by Dr. Alvin L. Young (1942- ). Dr. Young developed the collection as he conducted extensive research on the military defoliant Agent Orange. The collection is in good condition and includes letters, memoranda, books, reports, press releases, journal and newspaper clippings, field logs and notebooks, newsletters, maps, booklets and pamphlets, photographs, memorabilia, and audiotapes of an interview with Dr. Young.&lt;/p&gt;&#13;
&lt;p&gt;For more about this collection, &lt;a href="/exhibits/speccoll/exhibits/show/alvin-l--young-collection-on-a"&gt;view the Agent Orange Exhibit.&lt;/a&gt;&lt;/p&gt;</text>
                </elementText>
              </elementTextContainer>
            </element>
          </elementContainer>
        </elementSet>
      </elementSetContainer>
    </collection>
    <itemType itemTypeId="1">
      <name>Text</name>
      <description>A resource consisting primarily of words for reading. Examples include books, letters, dissertations, poems, newspapers, articles, archives of mailing lists. Note that facsimiles or images of texts are still of the genre Text.</description>
      <elementContainer>
        <element elementId="52">
          <name>Box</name>
          <description>The box containing the original item.</description>
          <elementTextContainer>
            <elementText elementTextId="31611">
              <text>119</text>
            </elementText>
          </elementTextContainer>
        </element>
        <element elementId="53">
          <name>Folder</name>
          <description>The folder containing the original item.</description>
          <elementTextContainer>
            <elementText elementTextId="31612">
              <text>3200</text>
            </elementText>
          </elementTextContainer>
        </element>
        <element elementId="54">
          <name>Series</name>
          <description>The series number of the original item.</description>
          <elementTextContainer>
            <elementText elementTextId="31614">
              <text>Series VI Subseries II</text>
            </elementText>
          </elementTextContainer>
        </element>
      </elementContainer>
    </itemType>
    <elementSetContainer>
      <elementSet elementSetId="1">
        <name>Dublin Core</name>
        <description>The Dublin Core metadata element set is common to all Omeka records, including items, files, and collections. For more information see, http://dublincore.org/documents/dces/.</description>
        <elementContainer>
          <element elementId="39">
            <name>Creator</name>
            <description>An entity primarily responsible for making the resource</description>
            <elementTextContainer>
              <elementText elementTextId="31609">
                <text>Camoni, I</text>
              </elementText>
              <elementText elementTextId="31610">
                <text>et al.</text>
              </elementText>
            </elementTextContainer>
          </element>
          <element elementId="50">
            <name>Title</name>
            <description>A name given to the resource</description>
            <elementTextContainer>
              <elementText elementTextId="31613">
                <text>Analytical Techniques for 2,3,7,8-Tetrachlorodibenzo-p-dioxin Detection in Environmental Samples After the Industrial Accident at Seveso</text>
              </elementText>
            </elementTextContainer>
          </element>
        </elementContainer>
      </elementSet>
    </elementSetContainer>
  </item>
  <item itemId="4106" public="1" featured="0">
    <collection collectionId="30">
      <elementSetContainer>
        <elementSet elementSetId="1">
          <name>Dublin Core</name>
          <description>The Dublin Core metadata element set is common to all Omeka records, including items, files, and collections. For more information see, http://dublincore.org/documents/dces/.</description>
          <elementContainer>
            <element elementId="50">
              <name>Title</name>
              <description>A name given to the resource</description>
              <elementTextContainer>
                <elementText elementTextId="4687">
                  <text>Alvin L. Young Collection on Agent Orange</text>
                </elementText>
              </elementTextContainer>
            </element>
            <element elementId="41">
              <name>Description</name>
              <description>An account of the resource</description>
              <elementTextContainer>
                <elementText elementTextId="49809">
                  <text>&lt;p style="margin-top: -1em; line-height: 1.2em;"&gt;The Alvin L. Young Collection on Agent Orange comprises 120 linear feet and spans the late 1800s to 2005; however, the bulk of the coverage is from the 1960s to the 1980s and there are many undated items. The collection was donated to Special Collections of the National Agricultural Library in 1985 by Dr. Alvin L. Young (1942- ). Dr. Young developed the collection as he conducted extensive research on the military defoliant Agent Orange. The collection is in good condition and includes letters, memoranda, books, reports, press releases, journal and newspaper clippings, field logs and notebooks, newsletters, maps, booklets and pamphlets, photographs, memorabilia, and audiotapes of an interview with Dr. Young.&lt;/p&gt;&#13;
&lt;p&gt;For more about this collection, &lt;a href="/exhibits/speccoll/exhibits/show/alvin-l--young-collection-on-a"&gt;view the Agent Orange Exhibit.&lt;/a&gt;&lt;/p&gt;</text>
                </elementText>
              </elementTextContainer>
            </element>
          </elementContainer>
        </elementSet>
      </elementSetContainer>
    </collection>
    <itemType itemTypeId="1">
      <name>Text</name>
      <description>A resource consisting primarily of words for reading. Examples include books, letters, dissertations, poems, newspapers, articles, archives of mailing lists. Note that facsimiles or images of texts are still of the genre Text.</description>
      <elementContainer>
        <element elementId="52">
          <name>Box</name>
          <description>The box containing the original item.</description>
          <elementTextContainer>
            <elementText elementTextId="31142">
              <text>118</text>
            </elementText>
          </elementTextContainer>
        </element>
        <element elementId="53">
          <name>Folder</name>
          <description>The folder containing the original item.</description>
          <elementTextContainer>
            <elementText elementTextId="31143">
              <text>3141</text>
            </elementText>
          </elementTextContainer>
        </element>
        <element elementId="54">
          <name>Series</name>
          <description>The series number of the original item.</description>
          <elementTextContainer>
            <elementText elementTextId="31147">
              <text>Series VI Subseries II</text>
            </elementText>
          </elementTextContainer>
        </element>
      </elementContainer>
    </itemType>
    <elementSetContainer>
      <elementSet elementSetId="1">
        <name>Dublin Core</name>
        <description>The Dublin Core metadata element set is common to all Omeka records, including items, files, and collections. For more information see, http://dublincore.org/documents/dces/.</description>
        <elementContainer>
          <element elementId="39">
            <name>Creator</name>
            <description>An entity primarily responsible for making the resource</description>
            <elementTextContainer>
              <elementText elementTextId="31140">
                <text>Adamoli, P</text>
              </elementText>
              <elementText elementTextId="31141">
                <text>et al.</text>
              </elementText>
            </elementTextContainer>
          </element>
          <element elementId="48">
            <name>Source</name>
            <description>A related resource from which the described resource is derived</description>
            <elementTextContainer>
              <elementText elementTextId="31144">
                <text>Ecological Bulletins</text>
              </elementText>
            </elementTextContainer>
          </element>
          <element elementId="40">
            <name>Date</name>
            <description>A point or period of time associated with an event in the lifecycle of the resource</description>
            <elementTextContainer>
              <elementText elementTextId="31145">
                <text>1978</text>
              </elementText>
            </elementTextContainer>
          </element>
          <element elementId="50">
            <name>Title</name>
            <description>A name given to the resource</description>
            <elementTextContainer>
              <elementText elementTextId="31146">
                <text>Analysis of 2,3,7,8-Tetrachlorodibenzo-para-dioxin in the Seveso Area</text>
              </elementText>
            </elementTextContainer>
          </element>
        </elementContainer>
      </elementSet>
    </elementSetContainer>
  </item>
  <item itemId="4048" public="1" featured="0">
    <collection collectionId="30">
      <elementSetContainer>
        <elementSet elementSetId="1">
          <name>Dublin Core</name>
          <description>The Dublin Core metadata element set is common to all Omeka records, including items, files, and collections. For more information see, http://dublincore.org/documents/dces/.</description>
          <elementContainer>
            <element elementId="50">
              <name>Title</name>
              <description>A name given to the resource</description>
              <elementTextContainer>
                <elementText elementTextId="4687">
                  <text>Alvin L. Young Collection on Agent Orange</text>
                </elementText>
              </elementTextContainer>
            </element>
            <element elementId="41">
              <name>Description</name>
              <description>An account of the resource</description>
              <elementTextContainer>
                <elementText elementTextId="49809">
                  <text>&lt;p style="margin-top: -1em; line-height: 1.2em;"&gt;The Alvin L. Young Collection on Agent Orange comprises 120 linear feet and spans the late 1800s to 2005; however, the bulk of the coverage is from the 1960s to the 1980s and there are many undated items. The collection was donated to Special Collections of the National Agricultural Library in 1985 by Dr. Alvin L. Young (1942- ). Dr. Young developed the collection as he conducted extensive research on the military defoliant Agent Orange. The collection is in good condition and includes letters, memoranda, books, reports, press releases, journal and newspaper clippings, field logs and notebooks, newsletters, maps, booklets and pamphlets, photographs, memorabilia, and audiotapes of an interview with Dr. Young.&lt;/p&gt;&#13;
&lt;p&gt;For more about this collection, &lt;a href="/exhibits/speccoll/exhibits/show/alvin-l--young-collection-on-a"&gt;view the Agent Orange Exhibit.&lt;/a&gt;&lt;/p&gt;</text>
                </elementText>
              </elementTextContainer>
            </element>
          </elementContainer>
        </elementSet>
      </elementSetContainer>
    </collection>
    <itemType itemTypeId="1">
      <name>Text</name>
      <description>A resource consisting primarily of words for reading. Examples include books, letters, dissertations, poems, newspapers, articles, archives of mailing lists. Note that facsimiles or images of texts are still of the genre Text.</description>
      <elementContainer>
        <element elementId="52">
          <name>Box</name>
          <description>The box containing the original item.</description>
          <elementTextContainer>
            <elementText elementTextId="30737">
              <text>111</text>
            </elementText>
          </elementTextContainer>
        </element>
        <element elementId="53">
          <name>Folder</name>
          <description>The folder containing the original item.</description>
          <elementTextContainer>
            <elementText elementTextId="30738">
              <text>3077</text>
            </elementText>
          </elementTextContainer>
        </element>
        <element elementId="54">
          <name>Series</name>
          <description>The series number of the original item.</description>
          <elementTextContainer>
            <elementText elementTextId="30742">
              <text>Series V</text>
            </elementText>
          </elementTextContainer>
        </element>
      </elementContainer>
    </itemType>
    <elementSetContainer>
      <elementSet elementSetId="1">
        <name>Dublin Core</name>
        <description>The Dublin Core metadata element set is common to all Omeka records, including items, files, and collections. For more information see, http://dublincore.org/documents/dces/.</description>
        <elementContainer>
          <element elementId="39">
            <name>Creator</name>
            <description>An entity primarily responsible for making the resource</description>
            <elementTextContainer>
              <elementText elementTextId="30735">
                <text>Latalski, M.</text>
              </elementText>
              <elementText elementTextId="30736">
                <text>et al.</text>
              </elementText>
            </elementTextContainer>
          </element>
          <element elementId="48">
            <name>Source</name>
            <description>A related resource from which the described resource is derived</description>
            <elementTextContainer>
              <elementText elementTextId="30739">
                <text>Annales Universitatis Mariae Curie-Sklodowska Lublin-Polonia</text>
              </elementText>
            </elementTextContainer>
          </element>
          <element elementId="40">
            <name>Date</name>
            <description>A point or period of time associated with an event in the lifecycle of the resource</description>
            <elementTextContainer>
              <elementText elementTextId="30740">
                <text>1980</text>
              </elementText>
            </elementTextContainer>
          </element>
          <element elementId="50">
            <name>Title</name>
            <description>A name given to the resource</description>
            <elementTextContainer>
              <elementText elementTextId="30741">
                <text>An Effect of Acute Poisoning with Herbicide 2,4-D on the Granulogenesis in Eosinophiles</text>
              </elementText>
            </elementTextContainer>
          </element>
        </elementContainer>
      </elementSet>
    </elementSetContainer>
  </item>
</itemContainer>
